background image

 

14 Technical Data 

 

 

 

 

BDC-1114PM

 

BDC-1114PH

 

110V-50Hz 

 

BDC-1114PM

 

BDC-1114PH

 

120V-60Hz 

 

BDC-1114PM

 

BDC-1114PH

 

230V 

 

Power consumption 

1,2 kW 

1,2 kW 

1,2 kW 

 

 

 

 

Max. power 

1,4 kW 

1,4 kW 

1,4 kW 

Electrical connection /

 

frequency 

 

220-240V / 50-60 Hz 

100-120V / 50 Hz 

100-120V / 60 Hz 

 

Air flow at hose end

 

Air flow at blower 

140 m3/hr/SE 

230 m3/hr/SE 

140 m3/hr/SE 

230 m3/hr/SE 

140 m3/hr/SE 

230 m3/hr/SE 

 

 

 

 

Under pressure at hose end

 

Under pressure at blower 

225 hPa/SE 

259 hPa/SE 

225 hPa/SE 

259 hPa/SE 

225 hPa/SE 

259 hPa/SE 

 

 

 

 

 

Weight 

17.1 kg 

17.1 kg 

17.1 kg 

 

Noise level 

Up to 69.5 dB(A) 

Up to 69.5 dB(A) 

Up to 69.5 dB(A) 

 

 

 

 

BDC-1114 

PH CA ASBESTOS

 

230V 

BDC-1114 

PH CA ASBESTOS

 

110V-50Hz 

BDC-1114 

PH CA ASBESTOS

 

120V-60Hz 

 

 

 

 

 

Power consumption 

1,2 kW 

1,2 kW 

1,2 kW 

 

 

Max. power 

1,2 kW 

1,2 kW 

1,2 kW 

Electrical connection /

 

frequency 

 

220-240V / 50-60 Hz 

100-120V / 50 Hz 

100-120V / 60 Hz 

 

Air flow at hose end

 

Air flow at blower 

140 m3/hr/SE 

230 m3/hr/SE 

140 m3/hr/SE 

230 m3/hr/SE 

140 m3/hr/SE 

230 m3/hr/SE 

 

 

 

 

Under pressure at hose end

 

Under pressure at blower 

225 hPa/SE 

259 hPa/SE 

225 hPa/SE 

259 hPa/SE 

225 hPa/SE 

259 hPa/SE 

 

 

 

 

 

Weight 

17.1 kg 

17.1 kg 

17.1 kg 

 

Noise level 

Up to 69.5 dB(A) 

Up to 69.5 dB(A) 

Up to 69.5 dB(A) 

 

Dimensions for all models (LxBxH): 53 cm x 40 cm x 55 cm.

 

Connection line on vacuum cleaners with plug socket:

 

H07RN-F 3x1,5 

 

15 Tests and approvals 

 

 

Electro-technical tests must be carried out in accordance

 

With the accident prevention regulations (BGV A3) and in

 

Accordance with DIN VDE 0701 Part 1 and Part 3. 

These tests are required in accordance with DIN VDE 0702

 

at regular intervals and after repair or modification. A dust- 

technical check must be carried out at least once a year, or

 

more frequently as may be specified by national requirements,

 

by the manufacturer or a trained person, e. g. for damage 

to the filter, dust-tightness of the vacuum cleaner, function

 

of the monitoring equipment. 

The vacuum cleaners are successfully tested in accordance

 

with IEC/EN 60335–2–69 including annex AA. 

 

 

 

Information

 

 

 

Old equipment contains valuable materials

 

which are designed for re-processing.

   

The vacuum cleaners must not be

 

thrown away in the normal household

 

waste,  but should be disposed of at a

 

suitable proper collection system, e. g. via

 

your communal disposal location. 

 

14 

Содержание BDC-1114PH CA ASBESTOS

Страница 1: ...Original Operating Instructions VERSION 1 9 BDC 1114PM BDC 1114PH BDC 1114PH CA ASBESTOS...

Страница 2: ...K L A Driving handle ES 012834 F Accessory storage ES 512723 B Suction hose 35 mm ES 413235 G PE emptying and disposal bag E06260 5x C M class filter ES 423159 H PE bag for ASBESTOS ES 430249 5x Set...

Страница 3: ...evices are suitable for aspiration clearing of BDC 1114PM M BDC 1114PH dry non combustible dusts non combustible liquids wood dusts and hazardous dusts with workplace limit values of 0 1 mg m Class H...

Страница 4: ...ntenance operations including removal of the dust collection means must only be carried out by authorised personnel wearing suitable personal protection Do not operate without the full filtration syst...

Страница 5: ...taken according to the best technical measures available At the end of work the tools including exhaust ducts work equipment and the work area must be carefully cleaned With asbestos fibres contamina...

Страница 6: ...g or ageing or any invisible defect is suspected after a fall Do not allow the rotating brushes to get into contact with the power connection line Do not operate the vacuum device where there is dange...

Страница 7: ...sical sensory or intellectual abilities or lack of experience or knowledge unable to safely use the vacuum device should not use it without supervision or instruction by a responsible person Particula...

Страница 8: ...mitted Setting the suction hose diameter Determine the maximum negative pressure for automatic shaking Read the operating manual carefully before starting to use the vacuum cleaner It provides importa...

Страница 9: ...to AR for standby mode The vacuum cleaner is ready for suction After vacuum cleaning set the switch to O The vacuum cleaner is switched off Pull the mains plug of the vacuum cleaner out of the plug so...

Страница 10: ...r cleaning during the operation Thereby constant high air flow cleaning guaranteed during the operation even for critical types of dust 7 Emptying the container Information Only permitted for dust wit...

Страница 11: ...erture with the mark pointing upwards 8 Changing the filter 8 1 Changing the folding filter Shake the folding filter cassettes before changing them Turn the lock on the latch through 90 in a counter c...

Страница 12: ...checked at least once a year There must be an adequate air exchange rate L in the room if the exhaust air returns to the room Further information can be taken from your national regulations If the suc...

Страница 13: ...to position see 6 4 Vacuum cleaner classes M or H with inserted paper filter dust in filter Position of rotary slider incorrect Set rotary slider to position see 6 3 Do not take any other action and...

Страница 14: ...a SE 259 hPa SE 225 hPa SE 259 hPa SE 225 hPa SE 259 hPa SE Weight 17 1 kg 17 1 kg 17 1 kg Noise level Up to 69 5 dB A Up to 69 5 dB A Up to 69 5 dB A Dimensions for all models LxBxH 53 cm x 40 cm x 5...

Страница 15: ...itions set out in the Machinery Directive 2006 42 EC ROHS Directive 2011 65 EU EMC Directive 2004 108 EC Where appropriate are in conformity with the following harmonized standards EN 60335 1 2002 A15...

Страница 16: ...16 Inspection comments Inspection before initial operation on By Date of initial operation Recurring inspections Date Findings Repairs Cleaning Test on By...

Страница 17: ...17 competent person Other comments...

Страница 18: ...SERVICE MANUAL BDC 1114 VERSION 1 5...

Страница 19: ...Index 1 Assembly plans Spare parts 04 Contact 07 2...

Страница 20: ...3 1 Assembly plans Spare parts...

Страница 21: ...Operating Unit 4...

Страница 22: ...ket 110V 60Hz USA ES516776 Power tool plug socket 110V 50Hz UK 12 50 51 52 ES432694 Electronic plate pressure switch insulating disc vacuum tube 1 13 ES408460 Holding disc 4 14 ES417707 Motor plug soc...

Страница 23: ...6 Suction unit...

Страница 24: ...1 ES408767 Electrode clamping piece 2 40 41 ES414775 Motor 230V upper sealing 1 40 ES414836 Motor 110V ES403762 Set carbon brushes 1 41 41 1 ES408774 Motor sealings 1 42 ES411484 Lower housing 1 43 ES...

Страница 25: ...1851 Container 1 2 ES511399 Axle 1 3 4 5 ES408347 Wheel complete 2 4 ES408903 Wheel plug 2 5 ES408941 Wheel over 2 6 ES408408 Castor wheel 2 7 ES512549 Discharge bolt 1 8 ES408958 Drain set 1 9 ES4069...

Страница 26: ...noted on shipping receipt Hand Tool Products Blastrac warrants its BLASTRAC Hand Tool Products including hand grinders and accessories against defects in material and workmanship under normal and prop...

Страница 27: ...otors batteries tires and all other parts See component manufacture warranty 7 Blastrac reserves the right to make product changes or improvements without prior notice and without undertaking any obli...

Страница 28: ...Warranty Registration IMPORTANT To ensure that your Blastrac machine is covered under warranty please provide the information recorded here by registering online at blastrac com or complete this page...

Страница 29: ...Contact Blastrac NA 13201 North Santa Fe Avenue Oklahoma City OK 73114 Tel 800 256 3440 Fax 405 478 8608 www blastrac com...

Отзывы: