background image

 

 

8

 

Operating manual  BDC-1112

 

8/16

 

[email protected] 

 

The suitable precautions include decontamination before disassembling the dust 
collector, adequate filtered ventilation of the exhaust air from the room in which it 
is disassembled, cleaning of the maintenance area and suitable personal 
protection. 

 

The external parts of the class M or H dust collector must be decontaminated by 
cleaning and vacuuming methods, de-dusted or treated with sealant before being 
taken out from the hazardous zone. All parts of the dust collector must be 
considered as contaminated when they are removed from the hazardous zone and 
appropriate actions must be taken to prevent dust from dispersing. 

 

When maintenance or repair procedures are carried out, all the contaminated 
elements that cannot be properly cleaned, must be destroyed. 

 

These elements must be disposed of in sealed bags according to the applicable 
regulations and in accordance with the local laws governing the disposal of such 
material.  

 

This procedure must also be followed when the filters (main or HEPA) have to be 
disposed. 

 

Compartments that are not dust-tight must be opened with suitable tools and 
thoroughly cleaned. 

 

Safety regulations 

 

Persons who are not operating the machine must not be permitted to stay in the 
surrounding area of the machine. 

 

Don’t change anything on the machine. Use always cables which are approved and 
safety earthed (extend) cables. The machine is always equipped with an earthed 
connection, do not change this and use always earthed cables with an earthed 
plug. 

 

Connect the main power supply cable to an installation with an earth leakage 
circuit breaker. 

 

Inspect and test the electrical components regularly. The electrical components 
have to satisfy to the requirements which apply to these components. 

 

Always call a skilled electrician or your distributor when you have questions about 
the safety of the electrical components. 

 

Work on electrical equipment or operating materials may only be undertaken by a 
skilled electrician or by trained persons under the guidance and supervision of a 
skilled electrician as well as in accordance with the electrical engineering 
regulations. 

 

Pull out the main plug during inspections and repair operations on the machine. 

 

Never operate the machine when the surface is wet. 

 

Never use the machine in the rain. 

 

Содержание BDC-1112

Страница 1: ...Gebruikershandleiding BDC 1112 EN Version 1 0 Operating manual BDC 1112 Operating manual info blastrac eu ...

Страница 2: ...d Safety requirements of the European Directive for machine Safety In case of changes to the machine without our written authorization this declaration loses its validity Model BDC 1112 Serial number 1 satisfies the conditions set out in the Machine Directive Directive 98 37 EC Low voltage directive 73 23 CEE as last amended EMC directive 89 336 CEE as last amended 2 satisfies the following harmon...

Страница 3: ...ccessories 3 Safety 06 Safety precautions general Safety precautions with regard to transport Safety regulations Labels 4 Initial operation 10 Checkpoints of electrical safety Functions 5 Operating 11 Dry cleaning Wet cleaning Plastic dust bag installation removing 6 Maintenance 12 Cleaning Filter replacement Fault diagnosis 7 Technical data 14 Contact 15 ...

Страница 4: ...ndard EN 60335 2 69 Annexe AA Type Class Designation BDC 1112 M Medium risk for separating dust with an exposure limit value of over 0 1 mg m3 depending on the volume occupied Dust emissions into the environment Class Value of performance L Retains at least 99 1 of particles measuring 3 µm M Retains at least 99 9 of particles measuring 3 µm H Class H13 HEPA filter in accordance with EN1822 The BDC...

Страница 5: ...2a Turn switch on off Automatic manual 8 Suction inlet 2b Power supply for auxiliary machines 9 Lock dustbin 2c Volume stream display 10 Wheels 2d Selection switch cleaning timer 11 Castor wheels Cooling air inlet 12 Filter cartridges 4 Display 13 Motor safety filter 5 Lock filter chamber 14 Plastic dust bag ...

Страница 6: ... out of a set 5 sealable plastic dust bags with a content of 25 litre 3 Safety Before operating the machine the personnel must be familiar with the safety instructions given in this manual Keep this manual near to the machine so that it may always be consulted 1 Suction hose 35 mm 1 Stainless steel tube handle with supplementary air slide 2 Stainless steel suction tubes 1 Crevice nozzle 1 Rubber s...

Страница 7: ...echnician Safety precautions with regard to transport Remove the dust from the dust collector before it is transported Close the inlet of the dust collector with the appropriate plug The dust collector may only be lifted and tightened by the housing frames The weight and dimensions of the dust collector are shown in Chapter 1 Technical data When transporting the dust collector do so in such a mann...

Страница 8: ...be disposed Compartments that are not dust tight must be opened with suitable tools and thoroughly cleaned Safety regulations Persons who are not operating the machine must not be permitted to stay in the surrounding area of the machine Don t change anything on the machine Use always cables which are approved and safety earthed extend cables The machine is always equipped with an earthed connectio...

Страница 9: ...nce contains dust hazardous to health Emptying and maintenance operations including removal of the dust collection means must only be carried out by authorised personnel wearing suitable personal protection Do not operate without the full filtration system fitted Type plate Descriptions Data regarding power supply IP enclosures Serial number CE marking ...

Страница 10: ...active voltage even when main switch 2a is put to Off In Off position this supply can be used for extension purposes such as light Maximum amperage the dust collector and connected tools must not exceed 16 Amps Functions The following functions are available Main switch 2a 0 dust collector Off 1 dust collector On A Automatic mode dust collector is activated by the connected tool RA Automatic mode ...

Страница 11: ...switching it off and on again Before emptying the dust collector take the suction hose out of the fluid After switching the machine off some fluid may run back out off the hose Before staring to dry clean again place a dry filter in the machine When frequently changing between dry and wet cleaning Blastrac B V recommends to purchase a second filter set preferable a polyester filter cartridge Plast...

Страница 12: ...12 Operating manual BDC 1112 12 16 info blastrac eu Below the procedure for installation and removing the plastic dust bags Installation new dust bag Removing full dust bag ...

Страница 13: ...renewed 1 Shake clean the filter cartridge with main switch 2a 2 With a coin or are other suitable tool the lock 5 located at lever 4 must be turned 90 anti clockwise and lever 4 must be pressed backwards 3 Hinge the cover backwards 4 Take out filter cartridges 12 out and seal them in a dust tight bag Dispose the polluted waste according to the local regulations 5 Place new filters 6 Close the cov...

Страница 14: ... run No power supply Connect power supply cable No active voltage at power supply Check if dust collector closed Shut off due to water sensor Plastic dust bag is sucked against filter Check position of turn button in dustbin is with marking upwards Any guarantee on the machine is expired when Non original Blastrac parts have been used Repair work is not done by qualified Blastrac personnel Changes...

Страница 15: ...rac eu 7 Technical data BDC 1112 Power consumption 1 2 kW Max power 1 4 kW Electrical connection fuel 220 240V 50 Hz Air stream hose end 140 m3 hr SE Under pressure hose end 225 hPa SE Power supply cable H05VV F3 x 1 5 Noise level Up to 69 5 dB A ...

Страница 16: ... 570 info blastrac co uk Blastrac France ZI 29 Avenue des Temps Modernes F 86360 Chasseneuil du Poitou Tel 0033 0 5 49 00 49 20 Fax 0033 0 5 49 00 49 21 info blastrac fr Blastrac Spain Calle Copernico 16 Nave 2 E 28820 Coslada Tel 0034 91 660 10 65 Fax 0034 91 672 72 11 info blastrac com es Blastrac Germany Mathias Brüggen Straße 144 D 50829 Köln Ossendorf Tel 0049 0 221 70 90 32 0 Fax 0049 0 221 ...

Отзывы: