EQM 100 / EQM 101 / EQM 102 Edge-QAM
Seite 6 (14)
www.blankom-digital.de
Rev. B
Reset
After a restart or reset the EQM 10x is operating again after approx. 7 sec. All parameters are stored and
the device will start with the last configuration.
Signalling during restart:
1.
Power LED is on, if both power supplies are connected
2.
IP LED at the front becomes green when an IP data stream is detected
3.
Status LED at the rear becomes green when device is ready
Configuration IP-Address
Although there is only one RJ-45 port each IP interface of the EQM family has two IP addresses. One is the
IP address for control (default:
192.168.200.20)
the other is for the streaming data. The streaming data
IP address is configurable with a standard web browser over the control IP address (see next chapter). If
you want to change the IP address of the control port you need an additional software tool named “DQAM
IPConfig”. If you start this program the following menus will come up.
Fig. 2:
Establish connection with default IP address
Fig. 3:
Change IP address and update the device