Blankom DRD 700 B-IRD Falcon Скачать руководство пользователя страница 1

 

 

BLANKOM Digital GmbH    TecCenter    31162 Bad Salzdetfurth     Germany     Tel. +49 (0) 5063 / 2711-0     Fax +49 (0) 5063 / 2711-60 

DRD 700  Quad Multistream Processor 

(548D13500002-Rev-D  08/11) 

www.blankom-digital.de

 

 

 

 

 
 

   DRD 700 

 
 
 
Quad Multistream Processor 

 

 

Instruction Manual 
 

Blankom Digital GmbH 
TecCenter 

31162 Bad Salzdetfurth 

Germany 

Phone 

+49 (0) 5063 / 2711 - 0 

Fax

 

+49 (0) 5063 / 2711 - 60

 

E-Mail 

[email protected]

 

Web

 www.blankom-digital.de 

 

Содержание DRD 700 B-IRD Falcon

Страница 1: ...60 DRD 700 Quad Multistream Processor 548D13500002 Rev D 08 11 www blankom digital de DRD 700 Quad Multistream Processor Instruction Manual Blankom Digital GmbH TecCenter 31162 Bad Salzdetfurth Germany Phone 49 0 5063 2711 0 Fax 49 0 5063 2711 60 E Mail info blankom digital de Web www blankom digital de ...

Страница 2: ...ital GmbH BLANKOM Digital GmbH reserves the right to revise this publication and make changes in its content from time to time whereby it shall not be obligatory for BLANKOM Digital GmbH to provide notification of such revision or change BLANKOM Digital GmbH provides this manual without warranty of any kind neither implied nor expressed this includes also any warranties regarding the merchantabili...

Страница 3: ...ST EQUIPMENT 5 SOFTWARE OPTIONS 5 ORDERING CODES 6 CONTROL WITH DISPLAY AND NAVIGATION WHEEL 7 OPERATION DISPLAY 7 DESCRIPTION OF MENU 7 CONTROL WITH WEB SERVER 8 HOME 8 INPUT 9 IP INPUT OPTION 9 INPUT DVB S S2 OPTION 10 COMMON INTERFACE 11 BISS DECRYPTION 12 MPTS OUTPUT 14 SPTS OUTPUT 14 LAN 15 LAN SNMP 16 LAN TELNET OPTION 17 SYSTEM 17 USER ACCOUNTS 19 UPDATE 20 VERSION 21 LICENSE 21 CONNECTIONS...

Страница 4: ...dditional option is Processing inclusive Service and PIF filtering as well as multiplexing of max four new transport streams from the input signals with table generation The device is operated locally either via a LCD display and an additional wheel or with the implemented web server via a web browser A SNMP agent with the corresponding MIB is built in for the integration in a network management s...

Страница 5: ...be indicated The input voltage range is 100V AC 240V AC In the event of an operational disturbance or a fault in the mains supply the configuration is stored in a non volatile memory Upon restart the operation automatically continues with the last setting Test Equipment Devices delivered for demonstration and test purposes might have a limited duration of functionality After exceeding the test per...

Страница 6: ...Customer related NDS certification BISS Decryption DCA 315 F038 01 BISS by CAM IP GbE Redundancy APA135 60 OPD13501 6000 Bund les Bundle SFP100 GbE Redundancy OPD135 30 OPD135013000 Electrical SFP Module RJ45 incl GbE Redundancy IP GbE Redundancy Activation of software options is described under Download Front view LED Marking Colour Function INPUT Green Red Orange Input signal available Input sig...

Страница 7: ...onfiguration with the navigation wheel If a parameter is changed SAVE appears in the display by pressing the navigation wheel this parameter can be selected for saving SAVE is displayed inversely the configuration is saved in the device by simply pressing the wheel After 30 sec the configuration mode is switched off automatically if the navigation wheel is not in use Operation display If an input ...

Страница 8: ...Preset Factory configuration Standard IP address 192 168 0 200 Control Port Subnet mask 255 255 255 0 Gateway address 192 168 0 1 Standard IP address 192 168 1 200 Data Port 1 Subnet mask 255 255 255 0 Gateway address 192 168 1 1 Standard IP address 192 168 1 201 Data Port 2 SFP Option Subnet mask 255 255 255 0 Gateway address 192 168 1 1 Home After configuring the current IP address of DRD 700 on...

Страница 9: ...ed A click on the particular transport stream number gives more status information about selected source IP Input option The input source IP is accessible if this option is activated IP 2 is configurable if the redundancy option is activated and a SFP modul is inserted Max four MPTS SPTS transport streams can be received via IP input By using IGMPv 3 the source port IP address can be specified SSM...

Страница 10: ...mbol rate must be precisely specified By pre selecting the DVB S or DVB S2 mode the tuning procedure of the DRD 700 is accelerated However the usual mode of operation is AUTOMATIC The menu items LNB Voltage and LNB 22 kHz Tone can be configured accordingly The SCPC mode should be enabled if a narrow band transport stream approx 5 Msps has to be received and if there are several narrow band transpo...

Страница 11: ...es the CAM can descramble Please use officially supported CAMs only to avoid decryption problems The menu item Common Interface provides information about the used CAM and the supported CA System ID of the encoding system With the CA PMT List you can select from different initialisation methods during the Multi Decryption function Some CAMs do not support all the methods only add The CA PMT list i...

Страница 12: ... agreed by the transmitting and receiving parties prior to transmission The key is entered into both the encoder and decoder this key then forms part of the encryption of the digital TV signal and only receivers with the correct key will decrypt the signal BISS Decryption with DRD700 is realized with Alphacrypt Classic Pro Select the appropriate slot CAM MMI 5 for Module Options 5 for BISS Setting...

Страница 13: ...a free BISS setting create a new setting or select a matched setting Enter the service ID in decimal format and the 6 SW bytes decimal After successful entering the settings go back to the service list Common Interface Slot x and set the CA Decryption of the appropriate service to ON ...

Страница 14: ...iver must be set to the corresponding multicast address The 4 MPTS transport streams can be switched to the ASI outputs SPTS Output The outgoing SPTS IP data streams are configured in this menu First select the service for the SPTS stream in the source list box and then configure the IP destination address and the port Standard protocol is UDP Multicast is possible by selecting the adequate multic...

Страница 15: ...es for the control port RJ45 control port and the Gigabit Ethernet Ports SFP data port are made under LAN Data device 1 is configured as standard Data device 2 is an option for redundancy and only configurable if the port has a licence If a SFP module is inserted additional information about vendor and status of the SFP are shown ...

Страница 16: ...vice can be integrated in an Network Management System NMS If an error fault occurs corresponding traps are sent to the NMS The target addresses for the traps can be entered in this menu Alarm Severity enables the user to activate SNMP traps for different types of events Under SNMP MIBs the MIBs of the DRD 700 can be downloaded out of the device ...

Страница 17: ...oggle between hexadecimal and decimal display format Power Supply Check If only one power supply is used the alarm Power Failure can be deactivated Otherwise the alarm is generated if one of the two power supplies is faulty Durch Reset erfolgt ein Neustart des Gerätes mit den abgespeicherten Parametern If you click Reset the device restarts with the saved parameters If you click Factory setting th...

Страница 18: ...or one of the transport streams TS1 to TS4 Time Offset deviation to GMT NTP Server IP addresses of NTP Server 1 and 2 NTP Sync Intervall time interval to synchronise the internal clock with time of the NTP server Daylight Saving Time summer wintertime 18urope only Sync Threshold maximum allowed deviation to synchronize the internal clock ...

Страница 19: ...rding to the user requirements so that the security of the device in a network is guaranteed Under Fallback Time you can configure the automatic fallback time after a login Access level allows to define four different user rights for selected WEB sites Admin is able to choose between four different classes of user rights for different accounts The user rights and accounts can be assigned by the Ad...

Страница 20: ... is possible to get this file to save it and to write it back to the DRD 700 again Click Get Konfiguration Save Config file DRD700_xxxxxxx dat Activating of Software Options Click Get Configuration Save the configuration file DRD700_xxxxxxx dat and send it via email to Blankom Digital service blankom digital de After receiving a written Order Blankom Digital will Create a Key file DRD700 Option Ke...

Страница 21: ...enu item Update The file that is read out must be sent to Blankom Digital along with the purchase order for the option A file that is delivered by Blankom Digital having the corresponding options is then loaded in DRD 700 via Download Activation of software options is not free of cost Logbook shows all logbook entries of the DRD 700 A maximum of 512 logbook entries can be stored Then the oldest en...

Страница 22: ... Correct working 1 3 closed Alarm 1 2 closed BNC 8 x ASI Out 1 4 a b Coaxial connector 75 Ohm BNC 2 x ASI In Coaxial connector 75 Ohm F RF Input Depending on the frontend SFP slot 1 GbE SFP SFP module SFP slot 2 GbE SFP SFP module Option Power input 2 ASI Outputs 4ab 3ab 2ab 1ab ASI Input 1 2 Ethernet 10 100 LAN Control port RF Frontend input 3 4 GbE SFP slot 2 RF Frontend input 1 2 Alarm CombiCon...

Страница 23: ...ng upon the type of modulation 3 5 2 3 4 5 5 6 8 9 9 10 DVB S2 16APSK 32APSK Only for Input 1 and 3 Modulation QPSK 8PSK 16APSK 32APSK incl DVB S Symbol rate 1 to 50 MS s QPSK 8PSK 1 to 40 MS s 16APSK 1 to 30 MS s 32APSK t b d Roll Off 20 25 35 FEC Code rates depending upon the type of modulation 1 3 2 5 3 5 2 3 4 5 5 6 8 9 9 10 FEC Frame Normal 64800bits Short 16200bits CCM ACM VCM DVB T Option M...

Страница 24: ...n input data rate ASI input Input 2 x ASI in conformance with EN 50083 9 75 Ohm BNC Reflection return loss 18 dB Format 188 204 Byte Data rate Max 200 Mbit s ASI output Output 8 x ASI in conformance with EN 50083 9 75 Ohm BNC Reflection return loss 18 dB Format 188 Byte Data rate Max 200 Mbit s Monitoring configuration Ethernet IP check port RJ45 LAN Format 10 100M TCP IP SNMP Web server Software ...

Страница 25: ... www blankom digital de Page 25 26 History Revision Modifications Name Date A First Release Haars 21 03 2011 B Editorial changes SPTS streaming Höper 22 07 2011 C BISS Decryption described Haars 12 08 2011 D Editorial changes Haars 23 08 2011 ...

Страница 26: ...tream Processor Page 26 26 www blankom digital de Rev D Blankom Digital GmbH TecCenter 31162 Bad Salzdetfurth Germany Phone 49 0 5063 2711 0 Fax 49 0 5063 2711 60 E Mail info blankom digital de Web www blankom digital de ...