10
AMB 307
Part N
o
: 9730.01
COFDM Modulator
ASI-TS
→
DVB-T (COFDM)
B
LINE
9. Manual menu control with Headend Controller (HCB x00)
10. SNMP Trap messages
Item
Message
Message type
Explanation
01
Power fail
CRITICAL
short circuit
02
System Reset
WARNING
reset by internal error
03
Input OK
INFORMATION
module works correctly
04
Input not sync
WARNING
no ASI input signal
05
IIC error
CRITICAL
IIC-Bus-error
06
TS-MUX not sync
WARNING
no transport stream at the FPGA
07
Internal controller reset
WARNING
error when accessing internal controller
08
FPGA: Program memory full
WARNING
overflow of program memory in the FPGA
09
FPGA: PID memory full
WARNING
overflow of PID memory in the FPGA
10
FPGA: Directory full
WARNING
overflow of Directory in the FPGA
11
FPGA: FAT memory full
WARNING
overflow of FAT memory in the FPGA
12
FPGA: TS-Packed buffer overflow
WARNING
overflow of TS packet buffer
13
Data overflow
CRITICAL
overflow of data
14
Sync error data FIFO
CRITICAL
data FIFO doesn’t work correctly
15
No response to OPEN command
CRITICAL
error internal port
16
FPGA ok
INFORMATION
data processing in FPGA is ok
AMB 307 start
Edit or End
Power Status
On/ Off
Output
Output frequency
45000 ... 862000 kHz
Attenuation
0 ... 31.5 dB
RF output
On/ Off
Level monitoring
On/ Off
Modulator Mode
Transcoder/ Test signal/ Test level
Spectrum
normal/ invers
Hierarch. modulation
Off/ On(Alpha=1)/
On(Alpha=2)/ On(Alpha=4)
Transmission
2k/ 8k
Constellation
16 QAM/ 64 QAM/ QPSK/
Bandwith
5/ 6/ 7/ 8 MHz
Guard interval
1/32, 1/16, 1/8, 1/4
PID program filtering
Program filter
On/ Off
Mode
Pass/ Drop
Other TS-Data
Pass/ Drop
Table processing
NIT processing
On/ Off
Network name
max. 30 characters
Network ID
0...65535
CAT processing
On/ On (CA Filter)/ Off
CA System ID
0...65535
Operator ID
0...65535
Change TS ID
On/ Off
TS Network ID
0...65535
TS ID
0...65535
Channel name
AMB 307 end