background image

Contents

1. Savety and operating instructions

 ..................................................................................................................

4

2. Device variants

 ...............................................................................................................................................

4

3. Software options

 ............................................................................................................................................

4

4

General ...........................................................................................................................................................

4

5. Explanation of the operating elements

 ..........................................................................................................

5

5.1  Front view

 ....................................................................................................................................................

5

5.2  Top view

 .......................................................................................................................................................

5

6. Functional description

 ....................................................................................................................................

5

7. Meaning of the LEDs

 .......................................................................................................................................

6

7.1  LEDs at the 10/100 Mbit ports

 .....................................................................................................................

6

7.2 Status LEDs

 ....................................................................................................................................................

6

8. Settings by web interface

 ...............................................................................................................................

7

8.1 Network connection to the computer

 ..........................................................................................................

7

8.2 Setting of individual parameters

 ...................................................................................................................

8

8.2.1 Menu ”RCL Home”

 .....................................................................................................................................

9

8.2.2 Menu ”SIM card”

 .......................................................................................................................................

9

8.2.3 Menu ”Port forwarding”

 ..........................................................................................................................

10

8.2.4 Menu ”VPN client”

 ..................................................................................................................................

11

8.2.5 Menu ”Serielle”

 .......................................................................................................................................

11

8.2.6 Menu ”Status”

 .........................................................................................................................................

12

8.2.7 Menu ”Service”

 ........................................................................................................................................

12

8.2.8 Menu ”Setup”

 ..........................................................................................................................................

13

9. Factory settings

 ............................................................................................................................................

18

10. Block diagram

 .............................................................................................................................................

19

11. Application example

 ...................................................................................................................................

19

11. Technical data

 .............................................................................................................................................

20

12. Bibliography

 ................................................................................................................................................

21

13. Notes on the software

 ................................................................................................................................

21

14. Document history

 .......................................................................................................................................

21

 Declaration of Conformity

 ...........................................................................................................................

22

Содержание 5161.20

Страница 1: ...Part no 5161 20 5161 21 Ethernet switch 8 fold Ethernet switch with remote connection Device Manual LANIOS RCL setting signals ...

Страница 2: ......

Страница 3: ... Settings by web interface 7 8 1 Network connection to the computer 7 8 2 Setting of individual parameters 8 8 2 1 Menu RCL Home 9 8 2 2 Menu SIM card 9 8 2 3 Menu Port forwarding 10 8 2 4 Menu VPN client 11 8 2 5 Menu Serielle 11 8 2 6 Menu Status 12 8 2 7 Menu Service 12 8 2 8 Menu Setup 13 9 Factory settings 18 10 Block diagram 19 11 Application example 19 11 Technical data 20 12 Bibliography 2...

Страница 4: ...oration of the modules is not be obstructed in any way If installed in mounting cabZinets a adequate heat circulation must be guaranteed The mounting in closed cabinets without air sufficient flow is not allowed For DIN rail mounting is important to note that between the heat sink and a neighboring module a distance of 0 79 is required If the modules mounted on top of each so they must be spaced 7...

Страница 5: ... are needed Due to its excellent properties the switch is also applicable for simple IP streaming tasks The module includes an UMTS and a LTE modem with an embedded server which enables the mapping of the communication modem Auto negotiation and auto MDI MDIX crossover are integrated IGMP snooping is supported 5161 20 5161 21 alternative plug in PSU 12V max 6W Port 1 4 LTE antenna connection AUX P...

Страница 6: ...t network cable is connected off no cable connection Data LED green flashing exchangeing data off no data exchange 7 2 Status LEDs Desingnation Color Status Meaning of the display POWER green constant module is ready yellow constant module is in standby off module is off operating voltage is not applied REMOTE ACCESS green constant active REMOTE connection off none REMOTE connection ...

Страница 7: ...ing an Ethernet cable The default IP address of the device is 192 168 1 100 In order to access the web interface of the LANIOS RCL from a PC the PC has to be in the same subnet 192 168 1 XXX subnet mask 255 255 255 0 where XXX is not used by any other device in this subnet If multiple modules are connected to the same network each module must be set to its own unique IP address to avoid address co...

Страница 8: ...r of your browser Therefor setting changes in the browser options could be necessary By default status information for the module are displayed below the navigation tree An option to move it on the right side instead is available GUI chapter 8 2 8 Here you find information about the system parameters An orange LED symbol indicates that an error has occured a green LED symbol means a correct workin...

Страница 9: ...cans the network for other SBL modules Then all available modules are listed They can be selected and added to the headend 8 2 2 Menu SIM card In this menu you set the parameters for the mobile connection of the switch At first enter your mobile service provider You can choose a provider from the drop down menu at the right The further data is entered automatically in the respective fields If the ...

Страница 10: ...owing port addresses must not be used 1194 4224 5000 5100 8000 Enter in the field Dest IP the address of the module in the local network which is to be accessed Dest Port asks for the value of the standard TCP IP port of the access mode e g port 80 for HTTP access Set the respective ports per module destination IP for the different types of access e g HTTP FTP Telnet The Append button adds the set...

Страница 11: ...rate a free entry is possible the input value is rounded to the next lower value that is supported The following baud rates are supported 921 600 576 000 500 000 460 800 230 400 115 200 57 600 38 400 19 200 9 600 4 800 2 400 1 800 1 200 600 300 200 150 134 110 75 50 0 Then choose for the RS 232 tunnel if you want to run the module in a server mode or in a client mode If the client mode has been se...

Страница 12: ...he various components updated every 5 seconds 8 2 7 Menu Service Here you find all service information the BLANKOM service hotline and e mail address the manual as pdf file and a link to the BLANKOM homepage where the latest software release is available Also the currently installed software release is displayed ...

Страница 13: ... of your browser instead must be allowed in the browser settings Display all system files By default System administration Backup all system files are up downloaded as a single file By selecting display all system files all system files are displayed Now specific files can be selected for up download Display tabs By default the tabs are shown in the upper part of the user interface Unselect this o...

Страница 14: ...he Overview page System administration By default the short list is displayed Backup The default is to save or load the complete configuration If under GUI setup Display all system files is selected all system files are listed The system files can also be loaded or saved separately Update Click the red colored Load button to load a software update The button View log leads to an overview in which ...

Страница 15: ...and by pressing the Send button Activated options are displayed in black inactive are grayed out Passwords This setting can only be done bya logged in administrator who has the permission to make administrative changes Inadditionthecheckbox GUIsettings Userandpassword check has to be enabled The user ID and password for the administrator can be set in the first line Up to 8 users and passwords can...

Страница 16: ...Server will be set up To use it in full extent a connected PC laptop must be configured as a DHCP client Note that using Windows not only the IP address but also the DNS server address has to be obtained automatically If the module is configured as a DHCP server or client and the client has received an IP address successfully the module can be accessed via a web browser using its name This name is...

Страница 17: ...can be sent by clicking the button Test If a test trap triggered all pre preserved traps are discarded Up to 256 IP addresses can be created resp unlocked to receive the traps They are listed under Receiver IP Third section Events are configured whether and with which thresholds they trigger traps There are three ways to configure a trap without parameters e g fan on off with a free selectable par...

Страница 18: ...es a power on off which is indicated by the REMOTE ACCESS LED Pressing the button for 2 to 10 seconds a reboot of the module is performed i e it will restart and set to the stored values If the module is to be reset to factory settings the reset button must be pressed more than 10 seconds In this case the module is set to the following Setup settings Network settings ...

Страница 19: ...S 8xPAL PALIOS DVB S S2 8xQAM QAMOS HELIOS P1 DVB S S2 8xQAM QAMOS 8CI DVB S S2 8xQAM QAMOS MEDIA LANIOS RCL Ansch Lte Ant Lte PALIOS 02 QUASARIOS PALIOS 02 QAMOS QAMOS 4CI MEDIA HELIOS P1 QAMOS 8CI QAMOS MEDIA LANIOS RCL LTE101 Zuführung DVB S S2 Signal Ausgang QAM PAL 192 168 1 101 192 168 1 102 192 168 1 103 192 168 1 104 192 168 1 105 192 168 1 106 feed in output QAM PAL ...

Страница 20: ...nality communication standards LTE UMTS GSM GSM fallback Frequency bands LTE 850 900 1800 2100 2600 MHz UMTS 900 2100 MHz GSM 900 1800 1900 MHz Connections antenna connector SMA SIM card slot standard SIM serial interface RS232 9 pole D subminiature Operating parameters voltage range 7 15 V DC max current consumption650 mA at 12 V DC power consumption about 8 W Environmental conditions temperature...

Страница 21: ... License or at your option any later version You should have received a copy of the GNU General Public License along with Foobar If not see http www gnu org licenses The source code is available upon request Please address requests to BLANKOM Antennentechnik GmbH Hermann Petersilge Straße 1 07422 Bad Blankenburg GERMANY 14 Document history Version Datum Modifikation Bearbeiter 1 00 31 07 2013 prel...

Страница 22: ... s of the Council for the approximation of legislation of the member states Electromagnetic compatibility 2004 108 EC The following standards are met DIN EN 50083 2 2007 04 EN 50083 2 2006 06 Low voltage guideline 2006 95 EC The following standards are met DIN EN 60950 1 2006 04 EN 60950 1 2006 11 Information technology equipment Safety Restriction of hazardous substances 2011 65 EC The following ...

Отзывы: