9
ADJUSTMENTS
Always disconnect the appliance from the
electricity main before making any adjustments.
All seals must be replaced by the technician at
the end of any adjustments or regulations.
Our burners do not require primary air
adjustment.
a) Data Label
The Data Label is located on the underside of the
hotplate. A duplicate Data Label is supplied to
adhere in an accessible area next to the hotplate.
This hotplate is suitable for Natural Gas and
Propane Gas; ensure that the available gas supply
matches the Data Label.
b) Before Leaving
Check that there are no gas leaks, but do not use a
naked flame to detect gas leaks. Ignite all burners
to ensure correct operation of gas valves, burners,
ignition and if fitted, flame failure valves. Turn gas
taps to low flame position and observe stability of
the flame. When satisfied with the hotplate, please
instruct the user on the correct method of operation.
In case the appliance fails to operate correctly after
all checks have been carried out, refer to the
authorised service provider in your area.
7) TAPS
Our taps are suitable for all gas, they are male
conical type.
“Reduced rate” adjustment
- Switch on the burner and turn the relative knob to
the “Reduced rate” position (small flame fig. 1).
- Remove knob “M” (fig. 10) of the tap, which is
simply pressed on to its rod.
- Insert a small screwdriver “D” into hole “C” (fig. 10)
and turn the throttle screw to the right or left until
the burner flame has been adequately regulated to
the “Reduced rate” position.
Check that the flame does not go out when the knob
is sharply switched from the “Full on” to the
“Reduced rate” position.
It is understood that only burners operating
with Natural gas should be subjected to the
above mentioned adjustments. The screw must
be fully locked when the burners operate with
Liquid gas.
FIG. 10
FIG. 9
FIG. 9/A
FIG. 9/B
Содержание CGG302FFC