IMPORTANT SAFETY INSTRUCTIONS

1.  Read these instructions.
2.  Keep these instructions.
3.  Heed all warnings.
4.  Follow all instructions.
5.  Do not use this apparatus near water.
6.  Clean only with dry cloth.
7.  Do not block any ventilation openings.
8.  Install in accordance with the manufacturer’s instructions.
9.  Do not install near any heat sources such as radiators, heat registers, stoves, or 

other apparatus (including amplifiers) that produce heat.

10. Do not defeat the safety purpose of the polarized or grounding-type plug. A 

polarized plug has two blades with one wider than the other. A grounding type 

plug has two blades and a third grounding prong. The wide blade or the third 

prong are provided for your safety. If the provided plug does not fit into your 

outlet, consult an electrician for replacement of the obsolete outlet.

11. Protect the power cord from being walked on or pinched particularly at plugs, 

convenience receptacles, and the point where they exit from the apparatus.

12. Only use attachments/accessories specified by the manufacturer.
13. Unplug this apparatus during lightning storms or when unused for long periods 

of time.

14. Refer all servicing to qualified service personnel. Servicing is required when the 

apparatus has been damaged in any way, such as power-supply cord or plug is 

damaged, liquid has been spilled or objects have fallen into the apparatus, the 

apparatus has been exposed to rain or moisture, does not operate normally, or 

has been dropped.

“TO COMPLETELY DISCONNECT THIS APPARATUS FROM THE AC MAINS, 

DISCONNECT THE POWER-SUPPLY CORD PLUG FROM THE AC RECEPTACLE”.
“WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT 

EXPOSE THIS APPARATUS TO RAIN OR MOISTURE. THE APPARATUS SHALL 

NOT BE EXPOSED TO DRIPPING OR SPLASHING AND THAT OBJECTS FILLED 

WITH LIQUIDS, SUCH AS VASES, SHALL NOT BE PLACED ON APPARATUS".

This symbol is intended to alert the user to the presence of 

uninsulated “dangerous voltage” within the product’s enclosure that 

may be of sufficient magnitude to constitute a risk of electric shock 

to persons.

This symbol is intended to alert the user to the presence of important 

operation and maintenance (servicing) instructions in the literature 

accompanying the appliance.

Содержание Sonnet 120

Страница 1: ...go to www blackstaramps com Whilst the information contained herein is correct at the time of publication due to our policy of constant improvement and development Blackstar Amplification Ltd reserves the right to alter specifications without prior notice Designed and Engineered by Blackstar Amplification UK 153406M 1 01 20 ...

Страница 2: ...s accessories specified by the manufacturer 13 Unplug this apparatus during lightning storms or when unused for long periods of time 14 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to...

Страница 3: ...cloth Condensation can form on the inside of an amplifier if it is moved from a cold environment to a warmer location Before switching the unit on it is recommended that the unit be allowed to reach room temperature Unauthorised modification of this equipment is expressly forbidden by Blackstar Amplification Ltd Never push objects of any kind into ventilation slots on the equipment casing Do not e...

Страница 4: ...s for practicing recording or live use The MP3 LINE IN jack allows you to connect your Sonnet 120 to a music device or drum machine to play along to or use the Bluetooth capability of the amp to make connecting to an external device even easier English 6 Introduction Thank you for purchasing this Blackstar Sonnet acoustic amplifier Like all our products this amp is the result of countless hours of...

Страница 5: ...ker in character As the control is increased clockwise the sound will become brighter and more lively English 7 9 Anti Feedback Adjust this control to suppress low frequency acoustic feedback Sweep from left to right in order locate the feedback frequency This will apply a tight filter to cut the problematic frequency At lower volumes and when feedback is not a problem then we recommend leaving th...

Страница 6: ...4 Reverb Time This control adjusts the length of the reverb tail At minimum settings the reverb tail will be short and at maximum settings the reverb tail will be long We recommend trying different Reverb levels and Reverb times to achieve the effect desired 25 H P Filter This controls a High Pass Filter Adjust this trim pot to roll off any low end frequencies from your amplifier s output At the m...

Страница 7: ...he Bluetooth connectivity is not active Rear Panel Channel 1 31 Effect Loop Send Connect to the mono input of an external effects unit here 32 Effect Loop Return Connect to the mono output of an external effects unit here 33 D I Output XLR This is a balanced output for connection to a PA mixing desk or interface for recording and monitoring Using a good quality screened cable the balanced XLR conn...

Страница 8: ... a suitable lead not supplied Standard audio drivers are used to connect the amplifier to a PC Mac or other applicable recording device No specific drivers are required A Camera Connection Kit can also be used to connect an iPad or iPhone for recording This will enable the amplifier to be recorded via your chosen mobile DAW For a guide on low latency USB recording visit www blackstaramps com usbre...

Страница 9: ...d socket and may cause damage to the structure of the amplifier Thermal Fuse Protection Sonnet 120 is designed for use with acoustic instruments with a pickup We do not recommend the use of instruments with a higher signal level for example keyboards distorted guitar tones synths etc Technical Specification Sonnet 120 Power 120 Watts Weight kg 11 5 Dimensions mm 417mm W x 352mm H x 296mm D Footswi...

Страница 10: ...OST PRE POST SONNET 120 MODEL 153102 VA HVIN 153102 VA FCC ID 2AFWP 153100VA IC 21116 153100VA SONNET 120 MODEL 153102 VA 153672M VA H CAN ICES 3 B NMB 3 B APPARATETS STIKPROP SKAL TILSLUTTES EN STIKKONTAKT MED JORD SOM GIVER FORBINDELSE TIL STIKPROPPENS JORD LAITE ON LIITETTÄVÄ SUOJAKOSKETTIMILLA VARUSTETTUUN PISTORASIAAN APPARATET MÅ TILKOPLES JORDET STIKKONTAKT APPARATEN SKALL ANSLUTAS TILL JOR...

Страница 11: ...UDIO CHAMBER PLATE REVERB TIME TYPE BRILLIANCE HIGH PASS FILTER MASTER PHANTOM 48V PAD GAIN LOW MID HIGH ANTI FEEDBACK REVERB 2 INPUT GAIN LOW MID HIGH ANTI FEEDBACK REVERB Sonnet 120 N A T U R A L R E S P O N S E SHAPE SHAPE PHASE PHASE Sonnet 120 Black Rear Panel English 88 Deutsch Français Español Japanese ...

Страница 12: ...English 90 Deutsch Français Español Japanese English Deutsch Français Japanese Español 89 ...

Отзывы: