Blackridge BRG650 Скачать руководство пользователя страница 8

8

SPECIFIC SAFETY 

INSTRUCTIONS

Warning!

 Do not use the generator in areas 

where there is a risk of explosion or 

fi

re from 

combustible materials.  The sparks possibly 
caused when using this generator may ignite 
combustible materials as well as 

fl

ammable 

liquids, paint, varnish, petrol, 

fl

ammable gases 

and dust of an explosive nature.  As a precaution 
it is recommended that you consult an expert on 
a suitable 

fi

re extinguisher and its use. Ensure 

that the work area is kept clear of combustible 
materials.

Warning!

 Do not use the generator indoors or in 

con

fi

ned spaces where exhaust gases, smoke or 

fumes could reach dangerous concentrations.
•  Never connect this generator to a second 

generator.

•  Never connect this generator to Commercial or 

Domestic power supply.

•  Only use 2 stroke motor oil to mix with 

unleaded fuel.

•  Premix 2 Stroke fuel before decanting into 

generator fuel tank.

•  Always use the generator in an open well 

ventilated area.

•  Unit will become hot during use.  Please keep 

generator at least one metre (1m) away from 
buildings, other equipment, pedestrian areas or 

fl

ammable materials.

•  Never pull the re-coil starter once the generator 

engine has started.  Any damage caused will 
not be covered by warranty.

•  Never start or stop the generator with any 

appliances attached.

•  Ensure the generator has stopped before 

servicing, or fuelling etc.

•  Do not attempt to modify the generator, guards 

or the supplied accessories in any way.

•  Do not touch the exhaust.  This can become 

very hot during operation and can cause serious 
burns.

•  Always check the generator for damaged parts 

or fuel leaks, ensure these are 

fi

xed before 

using it.

•  Never refuel while smoking or in the vicinity of 

an open 

fl

ame.

•  Always wear safety eye wear, ear and breathing 

protection when operating or refuelling the 
generator.

•  To avoid a 

fi

re if you spill fuel while refuelling, 

clean up before starting the generator.

•  Never operate or store the generator on its 

side, ALWAYS operate or store in an upright 
manner on 

fi

rm, solid ground.

•  Your generator is factory set, NEVER attempt 

to speed it up as this could endanger the user 
and damage the generator and/or attached 
appliances.

•  Never operate the generator in damp, wet or 

fl

ooded conditions.

•  Before plugging appliances into the generator 

allow it to run up to full speed.

•  If the generator makes an unfamiliar sound or 

vibrates excessively, switch the generator ‘OFF’ 
immediately. Investigate the possible cause or 
consult your authorised service agent.

•  Do not use ANY type of coolant on the 

generator as a fatal electric shock could occur.

•  Never use coolant in the generator as damage 

may occur.

•  Do not touch the generator with wet hands as 

this may cause electrocution.

•  Never use your generator on highly conductive 

surfaces e.g. steel walk ways, metal roof or 
metal bench, as this could cause an electric 
shock.

•  Always operate your generator at least two (2) 

metres away from conductive surfaces.

•  Locate this generator in a convenient place, 

avoid using long extension leads.

•  If an extension lead is used, avoid leaving it 

where it may be damaged by pedestrian or 
vehicular traf

fi

c or cause a trip and fall hazard.

•  Always observe normal safety precautions with 

ALL appliances used with this generator.

•  Never transport the generator with fuel in the 

tank.  ALWAYS empty the fuel tank.

•  All loads must be kept within the ratings stated 

on the name plate.  Overloading the generator 
will damage the unit or shorten its life.  This will 
not be covered under warranty.

•  Do not tamper or alter any parts as this may 

cause personal injury or damage the generator.

•  Always disconnect any loads before starting or 

stopping the generator.

•  When storing the generator always store in a 

secure well ventilated area.

•  Requires a minimum load of 200W to operate 

correctly.

Содержание BRG650

Страница 1: ...02824 08 11 For service spare parts or product information please contact Smart Marketing Group Pty Ltd AUST 1300 660 457 N Z 0800 474 876 650W Generators 50 1 2 Stroke...

Страница 2: ...nstructions 5 7 Specific Safety Instructions 8 Electrical Information 9 Components and Controls 10 Operating Instructions 11 16 Maintenance 16 17 Trouble Shooting 18 Parts Diagram 19 Contact Informati...

Страница 3: ...omponents of similar quality grade and composition where an identical part or component is not available Products presented for repair may be replaced by refurbished products of the same type rather t...

Страница 4: ...tion where an identical part or component is not available Products presented for repair may be replaced by refurbished products of the same type rather than being repaired Refurbished parts may be us...

Страница 5: ...with the supplied earth stake see page 12 BEWARE OF CHILDREN PETS Children and pets should be kept out of the operating area Children should not be allowed to touch or operate generators or touch exte...

Страница 6: ...our generator use only a damp soft cloth NEVER use liquid or solvents of any type EXTENSION CORDS REELS Inspect extension cords periodically and replace if damaged Never use damaged extension cord as...

Страница 7: ...ction when using or refuelling generators Prescription glasses do not have safety lenses Footwear Where there is the risk of heavy objects or if there is a risk of slipping on wet or slippery floors s...

Страница 8: ...he generator To avoid a fire if you spill fuel while refuelling clean up before starting the generator Never operate or store the generator on its side ALWAYS operate or store in an upright manner on...

Страница 9: ...covered under warranty Ensure you use clean fresh unleaded petrol ULP Use a clean approved container to store and mix your unleaded petrol ULP 2 stroke fuel mix in before decanting into the fuel tank...

Страница 10: ...ml 2 litre 40ml 3 litre 60ml 4 litre 80ml 5 litre 100ml 1 Use only unleaded petrol ULP and 2 stroke oil Ratio 50 1 2 Ensure you use clean fresh unleaded petrol ULP 2 stroke oil 3 Always wear approved...

Страница 11: ...k that the spark plug lead is firmly attached to the top of the spark plug 3 Ensure that NO appliances are connected to the generator 4 Holding on to the handle gently rock the generator and listen fo...

Страница 12: ...Turn the engine switch on by pushing to l see pic 4 3 Turn choke to start by sliding the choke lever to the left see Pic 5 4 Turn the fuel to ON by turning the fuel tap lever see Pic 5 5 Pull the rec...

Страница 13: ...liance on and use as per the manufacturers manual 4 When finished turn your appliance off 5 Disconnect appliance from the generator and the flap should close automatically NEVER leave any appliances p...

Страница 14: ...rcuit breaker does turn OFF 1 Turn the attached appliance OFF 2 Disconnect the appliance 3 Wait for 2 minutes for the circuit breaker to cool down 4 Re connect the appliance and turn it ON If the circ...

Страница 15: ...ator to cool before transporting or storing The fuel cap will leak fuel if transported with fuel in the fuel tank this is NOT a fault During use there will appear a misting layer of fuel on the fuel t...

Страница 16: ...ed signed and stamped this log to ensure your warranty is not void Fuel Tank Filter Pic 9 The fuel tank filter should be checked every time you fill up the fuel tank If dirty replace Your fuel tank fi...

Страница 17: ...replacement spark plug is Torch F6TC or NGK B5ES or BR5ES Air Filter Air filter should be checked daily and replaced every 50 hours operation or every 3 months which ever occurs first or whenever cons...

Страница 18: ...HOOTING Engine will not start Possible Cause Suggested Fix No or low fuel in the fuel tank Fill fuel tank Fuel Engine lever is OFF Turn fuel engine lever ON Choke is set to RUN Slide choke to START Po...

Страница 19: ...n SMG Part No 1 Tank Handle 84 BRG650TH Tank Handle Screw 84 BRG650HS 2 Tank 84 BRG650FT 3 Recoil Starter 84 BRG650RS User replaceable parts listed below All other parts must be serviced replaced by a...

Страница 20: ...This Service is to be complete within 100 hours or 6 months of purchase which ever comes first Replace Fuel tank filter Fuel line filter Air filter Spark Plug Authorised Service Agent Name or Company...

Отзывы: