Spark Plug

Spark plug should be checked every 50 hours 
(operation) or every 3 months and replaced every 
100 hours (operation) or every 6 months, which 
ever occurs 

fi

rst or whenever  

considered necessary.

1. Unplug the spark plug lead off the spark plug. 

Pic 10.

2. To clean use a wire brush/nail 

fi

le and remove 

the carbon deposits on spark plug base

3. Check the spark plug gap using a feeler gauge. 

The gap should be 0.7mm 

 0.8mm (0.028” 

 

0.031”)

4. The replacement spark plug is Torch F6TC or 

NGK B5ES or BR5ES.

Air Filter

Air 

fi

lter should be checked daily and replaced every 50 hours (operation) or every 3 months which ever 

occurs 

fi

rst or whenever considered necessary.

To check or replace the air 

fi

lter;

1. Remove the air 

fi

lter cover, see Pic. 11.

2. Remove air 

fi

lter element.

3. If dirty clean or replace air 

fi

lter element before using the generator.

4. Slide new air 

fi

lter element onto the air 

fi

lter box.

5. Replace air 

fi

lter element.

6. Replace the air 

fi

lter cover.

PIC. 10

PIC. 11

Lift plug cap off 

the spark plug

Use supplied spanner to 

remove the spark plug

Air 

fi

lter cover

Air 

fi

lter 

in side

Содержание BRG650

Страница 1: ...02824 08 11 For service spare parts or product information please contact Smart Marketing Group Pty Ltd AUST 1300 660 457 N Z 0800 474 876 650W Generators 50 1 2 Stroke...

Страница 2: ...nstructions 5 7 Specific Safety Instructions 8 Electrical Information 9 Components and Controls 10 Operating Instructions 11 16 Maintenance 16 17 Trouble Shooting 18 Parts Diagram 19 Contact Informati...

Страница 3: ...omponents of similar quality grade and composition where an identical part or component is not available Products presented for repair may be replaced by refurbished products of the same type rather t...

Страница 4: ...tion where an identical part or component is not available Products presented for repair may be replaced by refurbished products of the same type rather than being repaired Refurbished parts may be us...

Страница 5: ...with the supplied earth stake see page 12 BEWARE OF CHILDREN PETS Children and pets should be kept out of the operating area Children should not be allowed to touch or operate generators or touch exte...

Страница 6: ...our generator use only a damp soft cloth NEVER use liquid or solvents of any type EXTENSION CORDS REELS Inspect extension cords periodically and replace if damaged Never use damaged extension cord as...

Страница 7: ...ction when using or refuelling generators Prescription glasses do not have safety lenses Footwear Where there is the risk of heavy objects or if there is a risk of slipping on wet or slippery floors s...

Страница 8: ...he generator To avoid a fire if you spill fuel while refuelling clean up before starting the generator Never operate or store the generator on its side ALWAYS operate or store in an upright manner on...

Страница 9: ...covered under warranty Ensure you use clean fresh unleaded petrol ULP Use a clean approved container to store and mix your unleaded petrol ULP 2 stroke fuel mix in before decanting into the fuel tank...

Страница 10: ...ml 2 litre 40ml 3 litre 60ml 4 litre 80ml 5 litre 100ml 1 Use only unleaded petrol ULP and 2 stroke oil Ratio 50 1 2 Ensure you use clean fresh unleaded petrol ULP 2 stroke oil 3 Always wear approved...

Страница 11: ...k that the spark plug lead is firmly attached to the top of the spark plug 3 Ensure that NO appliances are connected to the generator 4 Holding on to the handle gently rock the generator and listen fo...

Страница 12: ...Turn the engine switch on by pushing to l see pic 4 3 Turn choke to start by sliding the choke lever to the left see Pic 5 4 Turn the fuel to ON by turning the fuel tap lever see Pic 5 5 Pull the rec...

Страница 13: ...liance on and use as per the manufacturers manual 4 When finished turn your appliance off 5 Disconnect appliance from the generator and the flap should close automatically NEVER leave any appliances p...

Страница 14: ...rcuit breaker does turn OFF 1 Turn the attached appliance OFF 2 Disconnect the appliance 3 Wait for 2 minutes for the circuit breaker to cool down 4 Re connect the appliance and turn it ON If the circ...

Страница 15: ...ator to cool before transporting or storing The fuel cap will leak fuel if transported with fuel in the fuel tank this is NOT a fault During use there will appear a misting layer of fuel on the fuel t...

Страница 16: ...ed signed and stamped this log to ensure your warranty is not void Fuel Tank Filter Pic 9 The fuel tank filter should be checked every time you fill up the fuel tank If dirty replace Your fuel tank fi...

Страница 17: ...replacement spark plug is Torch F6TC or NGK B5ES or BR5ES Air Filter Air filter should be checked daily and replaced every 50 hours operation or every 3 months which ever occurs first or whenever cons...

Страница 18: ...HOOTING Engine will not start Possible Cause Suggested Fix No or low fuel in the fuel tank Fill fuel tank Fuel Engine lever is OFF Turn fuel engine lever ON Choke is set to RUN Slide choke to START Po...

Страница 19: ...n SMG Part No 1 Tank Handle 84 BRG650TH Tank Handle Screw 84 BRG650HS 2 Tank 84 BRG650FT 3 Recoil Starter 84 BRG650RS User replaceable parts listed below All other parts must be serviced replaced by a...

Страница 20: ...This Service is to be complete within 100 hours or 6 months of purchase which ever comes first Replace Fuel tank filter Fuel line filter Air filter Spark Plug Authorised Service Agent Name or Company...

Отзывы: