background image

201-A00     page 7/12

 

MAINTENANCE

 

 

 

Failure to set the vehicle emergency 
brake and chock wheels before 
performing service can cause severe 
personal injury or property damage. 

 

 

Disconnecting fluid or pressure 
containment components during pump 
operation can cause serious personal 
injury, death or major property damage 

 

 

Hazardous pressure 

can cause personal 

injury or property 

damage 

 

Hazardous pressure 

can cause personal 

injury or property 

damage 

 

 

 

 

 

 

Failure to relieve system pressure prior 
to performing pump service or 
maintenance can cause personal injury 
or property damage. 

 

 

If pumping hazardous or toxic fluids, 
system must be flushed prior to 
performing service 

 

Hazardous pressure 

can cause personal 

injury or property 

damage 

 

Hazardous or toxic 

fluids can cause 

serious injury. 

 

 

Failure to disconnect and lockout 
electrical power or engine drive before 
attempting maintenance can cause 
severe personal injury or death 

 

 

Operation without guards in place can 
cause serious personal injury, major 
property damage, or death. 

 

 

Hazardous 

machinery can 

cause serious 

personal injury.

 

 

Do not operate 

without guard  

in place

 

 
 

NOTICE: 

Maintenance shall be performed by qualified technicians only, 

following the appropriate procedures and warnings as presented in this manual. 

 
 

STRAINERS 

Strainers must be cleaned regularly to avoid pump starvation.  
Schedule will depend upon the application and conditions. 
 
 

LUBRICATION 

NOTICE: 

To avoid possible entanglement in moving parts do not 
lubricate pump bearings,

 

hydraulic adapter coupling or 

any other parts while the pump is running

.

 

NOTICE: 

If pumps are repainted in the field, ensure that the grease 
relief fittings (76A) are functioning properly after 
painting.  Do NOT paint them closed.  Remove any 
excess paint from the fittings. 

Lubricate the ball bearings, and hydraulic motor couplings (if 
equipped), every three months at a minimum. 

 

 

Recommended Grease: 
Mobil® - Mobilgrease XHP222, 
Exxon® - RONNEX MP Greas

e, or equivalent. 

 

Manual Greasing Procedure: 

1.  Remove the grease relief fittings (76A) from the bearing 

covers (27A) or hydraulic motor adapter (135).  

2.  Apply grease with a hand gun until grease begins to 

escape from the grease relief fitting port.  

3.  Replace the grease relief fittings (76A). 

DO NOT overgrease pump bearings. While it is normal for 
some grease to escape from the grease tell-tale hole after 
lubrication, excessive grease on pumps equipped with 
mechanical seals can cause seal failure. 

Auto Greasing Systems: 

If end users choose to install/use auto greasing systems on 
their trucks, that system MUST be adjusted to match the 
pump requirements.  Over-greasing will cause seal failure – 
under-greasing will cause bearing failure. 
 

Содержание TX1.5

Страница 1: ...10 SAFETY DATA This is a SAFETY ALERT SYMBOL When you see this symbol on the product or in the manual look for one of the following signal words and be alert to the potential for personal injury death...

Страница 2: ...operty damage or death Hazardous machinery can cause serious personal injury Do not operate without guard in place PUMP DATA PUMP IDENTIFICATION A pump Identification tag containing the pump serial nu...

Страница 3: ...pported Mounting the pump with the cylinder feet down or with the intake port up is recommended for thorough draining of the pump PUMP DRIVE The pump may be driven by a power take off through universa...

Страница 4: ...ON NOTICE Confirm correct pump rotation by checking the pump rotation arrows respective to pump driver rotation TO CHANGE PUMP ROTATION TXD Models The TXD pump models are equipped with a double ended...

Страница 5: ...discharge lines 2 Start the pump Priming should occur within one minute 3 Check the vacuum and pressure gauges to ensure the system is operating within expected parameters Record the gauge readings i...

Страница 6: ...efore adjusting pump relief valve can cause severe personal injury or death Hazardous Machinery can cause severe personal injury or death Incorrect settings of the pressure relief valve can cause pump...

Страница 7: ...nings as presented in this manual STRAINERS Strainers must be cleaned regularly to avoid pump starvation Schedule will depend upon the application and conditions LUBRICATION NOTICE To avoid possible e...

Страница 8: ...s 28 and slide the outboard bearing cover 27A and gasket 26 off the shaft Discard the bearing cover gasket 4 If equipped with locknuts and lockwashers 24A 24B a Bend up the engaged lockwasher tang and...

Страница 9: ...emaining vanes into the top positions of the rotor Rotate the shaft by hand to engage the drive tangs of the seal jacket in the rotor slots 9 Install the inboard head 20 mechanical seal and bearing as...

Страница 10: ...r can cause serious personal injury major property damage or death Do not operate without guard in place 18 RELIEF VALVE ASSEMBLY If the pump is equipped with a Blackmer air valve refer to setting and...

Страница 11: ...oupling misaligned 8 Excessively worn rotor 9 Malfunctioning valve in the system 10 Relief valve setting too low 11 Damaged vanes see following category Damaged Vanes 1 Foreign objects entering the pu...

Страница 12: ...215 GPM HXL 6 8 10 Sliding Vane Pumps 130 to 2 220 GPM Refineries Terminals Barges Ships Reciprocating Gas Compressors Liquefied Gas Transfer Boosting Vapor Recovery Hand Operated Pumps Dispensing Tra...