BLACKMER LGL3021A Скачать руководство пользователя страница 11

 

501-L00    Page 11/12 

MAINTENANCE 

14.  Rotate the shaft by hand to engage the mechanical seal 

drive tangs, and to test for binding or tight spots. If the 
rotor does not turn freely, lightly tap the rims of the heads 
with a soft faced mallet until the correct position is found.  
Install all of the remaining head capscrews (21) for each 
head (20) and uniformly torque to 30 lbs ft (40.7 Nm). 

15. LOCKNUT ADJUSTMENT 

It is important that the bearing locknuts (24A) and lockwashers 
(24B) be installed and adjusted properly.  Overtightening 
locknuts can cause bearing failure or a broken lockwasher 
tang. Loose locknuts will allow the rotor to shift against the 
discs (71), causing wear. See Figure 11. 

 

Figure 11 - Locknut Adjustment 

 

a.   On both ends of the pump shaft, Install a lockwasher 

(24B) with the tangs facing outward, followed by a 
locknut (24A) with the tapered end inward. Ensure the 
inner tang "A" of the lockwasher is located in the slot in 
the shaft threads, bending it slightly, if necessary. 

b.   Tighten both locknuts (24A) to ensure that the bearings 

(24) are bottomed in the head recess. DO NOT 
overtighten and bend or shear the lockwasher inner 
tang. 

c.   Loosen both locknuts one complete turn. 

d.   Tighten one locknut until a slight rotor drag is felt when 

turning the shaft by hand. 

e.   Back off the nut the width of one lockwasher tang "B".  

Secure the nut by bending the closest aligned 
lockwasher tang into the slot in the locknut. The pump 
should turn freely when rotated by hand.

 

f.   Tighten the opposite locknut (24A) by hand until it is 

snug against the bearing (24). Then, using a spanner 
wrench, tighten the nut the width of one lockwasher 
tang. Tighten just past the desired tang, then back off 
the nut to align the tang with the locknut slot. Secure the 
nut by bending the aligned lockwasher tang into the slot 
in the locknut. The pump should continue to turn freely 
when rotated by hand. 

g.   To check adjustment, grasp the nut and washer with 

fingers and rotate back and forth. If this cannot be done, 
one or both locknuts are too tight and should be 
alternately loosened one stop at a time (.001" – 25 
microns). Begin by loosening the locknut adjusted last. 

16.  Inspect the grease seal (104) for wear or damage and 

replace as required. Grease the outside diameter of the 
grease seal and push it into the inboard bearing cover 
(27) with the lip of the seal inward. 

17.  Attach a new bearing cover gasket (26) and the bearing 

cover (27) to the inboard head (20). Make sure the 
grease fittings (76) are accessible. Install and torque the 
bearing cover capscrews (28) to 30 lbs ft (40.7 Nm). 

18.  Install the grease seal (104) and bearing cover (27) on 

the opposite side of the pump as instructed in steps 16 
and 17. 

19.  On 2-inch pump models, push the dirt shield (123A) over 

the inboard and outboard shafts and firmly against the 
bearing cover (27). 

20.  Attach the shaft protector (186) to the non-driven shaft 

end of double ended pumps. 

 

 

Operation without guards in place can 
cause serious personal injury, major 
property damage, or death. 

 

Do not operate 

without guard 

in place 

21.  See "Pre-Start Up Check List" and "Start Up Procedures" 

sections of this manual prior to restarting pump operation. 

 

 

TROUBLESHOOTING 

NOTICE: 

Maintenance shall be performed by qualified technicians only,  

following the appropriate procedures and warnings as presented in this manual. 

 

SYMPTOM PROBABLE 

CAUSE 

Pump Not Priming 

1.  Pump not wetted. 
2. Worn 

vanes. 

3.  Internal control valve closed. 
4. Strainer 

clogged. 

5.  Inlet line or valves clogged or too restrictive. 
6. Pump 

vapor-locked. 

7.  Pump speed too low for priming. 

8. 

Relief valve partially open, worn or not seating properly.

 

 

Содержание LGL3021A

Страница 1: ...www blackmer com or by contacting Blackmer Customer Service SAFETY DATA This is a SAFETY ALERT SYMBOL When you see this symbol on the product or in the manual look for one of the following signal word...

Страница 2: ...us or toxic fluids system must be flushed and decontaminated inside and out prior to performing service or maintenance Hazardous or toxic fluids can cause serious injury PUMP DATA PUMP IDENTIFICATION...

Страница 3: ...intake port on the pump Slope the pipe downward to the pump and do not install any upward loops Minimize the number of intake line fittings and eliminate restrictions such as sharp bends globe valves...

Страница 4: ...on all attached components Never start a pump when it is rotating in the reverse rotation as the added starting torque can damage the pump and related equipment PUMP ROTATION NOTICE Confirm correct p...

Страница 5: ...sheave capscrews 152C G 5 Measure the span length as shown in Figure 6 6 Adjust the motor base 183 and apply a specified force see Table 1 against the belt at the center of the span so that the belt...

Страница 6: ...closed valve can cause system failure personal injury and property damage Hazardous pressure can cause personal injury or property damage TRUCK MOUNTED PUMPS Failure to set the vehicle emergency brake...

Страница 7: ...is a Lever Operated Pull the control knob all the way out Manually check the lever under the truck to see that it is in the completely OPEN position b Discharge Pressure Operated Keep the discharge li...

Страница 8: ...sure can cause personal injury or property damage Hazardous or toxic fluids can cause serious injury NOTICE Maintenance shall be performed by qualified technicians only following the appropriate proce...

Страница 9: ...and 24B a Bend up the engaged lockwasher tang and rotate the locknut 24A counterclockwise to remove it from the shaft b Slide the lockwasher 24B off the shaft Inspect the lockwasher for damage and re...

Страница 10: ...See Figure 8 c After the bottom vanes and push rods are installed insert the rotor and shaft 13 fully into the casing 12 d Install the remaining vanes 14 into the top positions of the rotor 6 Install...

Страница 11: ...e tang with the locknut slot Secure the nut by bending the aligned lockwasher tang into the slot in the locknut The pump should continue to turn freely when rotated by hand g To check adjustment grasp...

Страница 12: ...shaft or drive coupling misaligned 9 Excessively worn rotor 10 Malfunctioning valve in the system 11 Relief valve setting too low 12 Liner installed backwards 13 Damaged vanes see following category...

Отзывы: