![BLACKMER HD082C Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/blackmer/hd082c/hd082c_installation-operation-and-maintenance-instructions_2767692015.webp)
MAINTENANCE
CB9A-005 page 15/28
Fig. 8 - Compressor Lubrication System
CRANKCASE LUBRICATION
Change the crankcase oil every 1,000 hours or 180 days,
whichever is shorter. Under severe dusty, sandy or wet
operating conditions, the oil should be changed every
500 hours or every 90 days.
If the crankcase oil becomes contaminated or diluted
due to gas leakage past the packing seals, the oil must
be changed more frequently. In such cases, change
the packing seals as soon as possible.
Non-detergent oils are recommended. Detergent oils
can be used providing the gas being handled does not
react with the detergent in the oil. If using a detergent
oil, be sure there is not a compatibility problem.
Ammonia, amine and imine gases are known to react
with many of the detergents in oil.
The oil used, detergent or non-detergent, should be
of high quality such as API grade SJ, SL, SM, SN or
similar.
API grade SA, SB, SC or similar oils should never
be used. Recycled oils should never be used.
Synthetic oils are acceptable; use the same guidelines
as mineral based lubricants. Consult factory for special
lubricating requirements.
Before changing the oil, bring the compressor up to
normal operating temperature. Remove the crankcase
drain plug and drain the oil into an adequately sized
container. Remove the oil pickup screen and clean in a
suitable solvent. When reinstalling the pickup screen,
inspect the metal gasket and the O-ring for damage,
replacing as necessary. If equipped, replace the external
oil filter. See Fig. 8.
Refill the crankcase via the dipstick or nameplate
opening.
DO NOT OVERFILL THE CRANKCASE!
The oil pump on these models will operate in either
direction of crankshaft rotation.
Models
Quarts
Liters
HD082C
1.9
1.8
Table 8 - Oil Capacity
Mineral Based Oil - API Grade SN, SM, SL, SJ
ISO
Grade
SAE
Ambient
Temperature
Product
100
30
80°F (27°C)
and above
Mobil®
Rarus 427
or
equivalent
46
20
32 to 80°F
(0 to 27°C)
32
10
0 to 32°F
(-18 to 0°C)
22 - 15
5 - 0
Below 0°F
(-18°C)
Synthetic Oil
ISO
Grade
SAE
Ambient
Temperature
Product
68
20+
Full Range
Mobil®
SHC Rarus
68
or
equivalent
Table 9 - Oil Viscosity
SETTING THE OIL PRESSURE
(see Fig. 8)
1. The oil pressure should be about 25 psig
(1.73 Barg).
2. Loosen the locknut.
3. Increase the pressure setting by turning the
adjusting screw inward, CLOCKWISE.
Decrease the pressure setting by turning the
adjusting screw outward, COUNTER-CLOCKWISE.