DEVICE CONTROL
29
4.1 Opening the OSD
You can access the OSD in three ways:
•
Using the keyboard attached to the Remote Unit:
Note. On USB devices (ACS253-U-xx) or DVI upgrade kits (ACS253A-DVI-xx),
keyboard access is not available. Please use one of the other methods.
•
Using a standard terminal program with a serial connection to the programming port.
•
Using our small WINDOWS™ program with a serial connection to the programming
port.
While the OSD is active, the mouse is locked and only menu keystrokes are allowed at the
keyboard. To indicate that the OSD mode is active, the status LEDs (Num Lock, Caps Lock
and Scroll Lock) are flashed. There is a summary of OSD commands on page 13.
Using the keyboard attached to the Remote Unit
Type the following key sequence at the Remote console keyboard:
<Ctrl> + <Shift> + < I >
Note.
On some keyboards,
<Ctrl>
is replaced by
<Strg>
.
To navigate within the OSD:
•
Use the left and right arrow keys to highlight a submenu and/or function.
•
Press the <ENTER> key to select the highlighted submenu or function.
•
Select the Exit icon to go back to the previous menu level.
•
Press the <ESC> key to exit the OSD mode.
Using a standard terminal program with a serial connection
On all devices, you can use a terminal (or terminal software) for OSD access:
1.
Connect the programming cable to the programming port of the Remote unit.
2.
Connect the programming cable to the serial port of a computer running a terminal
client.
3.
Set up the terminal to 115200 baud with 8 data bits, no parity and 1 stop bit, ASCII-
mode.
4.
Type in the following key sequence:
< O > + < S > + < D >
followed by
<ENTER>