INSTALLATION
21
3.2 Interconnection Cable Requirements
To connect the Local and Remote units you will need:
•
CATx Modules:
S/UTP (CAT5) cable acc. to EIA/TIA 56A or TSB 36 or Digital STP
17-03170. Four pairs AWG 24. Pinout acc. EIA/TIA 568A (10BaseT). Screen must be
connected on both ends. Please ensure that the connection is tension-free.
•
Multimode Modules:
Two fibers 50µm or 62.5µm.
•
Singlemode Modules:
Two fibers 9µm.
•
Power Supply
Connect the supplied 6V/DC power supplies to the
Plug
terminal on the rear of both
Local and Remote units.
USB devices have an additional power supply. You need to attach this PSU to the
Remote unit if the total power consumption of the attached USB devices exceeds 500mA
(see
Appendix E: USB – High Power/Low Power
).