Page 19
SET UP & USE
TO OPERATE ON AUTO
FEATURE:
• When you set the air conditioner in
AUTO mode, it will automatically
select cooling, heating (cooling only
models without), or fan only operation
depending on what temperature you
have selected and the room temperature.
• The air conditioner will control room
temperature automatically round the
temperature point set by you.
• In this mode, the fan speed cannot
be adjusted, it starts automatically
at a speed according to the room
temperature.
TO OPERATE ON FAN ONLY:
• Use this function only when cooling
is not desired, such as for room air
circulation or to exhaust stale air.
(Remember to open the vent during
this function, but keep it closed during
cooling for maximum cooling efficiency.)
You can choose any fan speed you prefer.
• During this function, the display will show
the actual room temperature, not the set
temperature as in the cooling mode.
• In Fan only mode, the temperature is not
adjusted.
TO OPERATE ON DRY MODE:
In this mode, the air conditioner will
generally operate in the form of a
is a closed or sealed area; some degree of
cooling will continue. On Dry mode, the fan
speed is controlled at Low automatically.
TIMER: AUTO START/STOP
FEATURE:
•
Press Timer button, the TIMER ON or
TIMER OFF indicator light illuminates.
It indicates the Auto Start or Auto Stop
program is initiated. For some units,
keep pressing the Timer button will
cancel the timer settings.
•
Press or hold the UP or DOWN button
to change the Auto time by 0.5-hour
increments, up to 10 hours, then at
1 hour increments up to 24 hours.
The control will count down the time
remaining until start.
•
The selected time will register in
5 seconds, and the system will
automatically revert back to display the
previous temperature setting or room
temperature when the unit is on (when
the unit is off, there is no display.)
•
Turning the unit ON or OFF at any time
or adjusting the timer setting to 0.0
will cancel the Auto Start/Stop timed
program.
DISPLAYS: Shows the set temperature in “
OC” or “ OF” and the Auto-timer settings.
While on Fan only mode, it shows the room
temperature. If the room temperature is
too high or low, it will display “ HI” or “ LO”
ERROR CODES:
AS - Room temperature sensor error
ES - Evaporator temperature sensor error
or •
HS -Electric heating sensor error (on some
models);
CS -Condenser temperature sensor error (on
some models);
OS -Outside temperature sensor error(on some
models);
E7 -Unit malfunction(on some models).
NOTE:
When error occurs, unplug the unit and
plug it back in. If error repeats, call for service.
NOTE:
If the unit breaks off unexpectedly due
to the power failure, it will restart with the
previous function setting automatically
when the power resumes.
ADDITIONAL THINGS YOU
SHOULD KNOW
Now that you have mastered the operating
procedure, here are more features in your control
that you should become familiar with:
• The Cool circuit has an automatic 3 minutes
time delayed start if the unit is turned off
and on quickly. This prevents overheating of
the compressor and possible circuit breaker
tripping. The fan will continue to run during this
time.
• The control is capable of displaying
temperature in degrees Fahrenheit or degrees
Celsius. To convert from one to the other, press
and hold the Up and Down buttons at the same
time for 3 seconds.