background image















17







 













®

Image controls - sharpness and brightness

The Wizard extender modules incorporate special controls to compensate for 
losses incurred within long cable links. Using these controls you can adjust the 
picture sharpness and brightness to improve your remote picture quality.  
The need for image control adjustment is best discovered when viewing high 
contrast images with vertical edges, such as black lines on a white background. 
When doing so, if you notice that the screen image is ‘fuzzy’ or ‘dark’ then the 
image controls may be able to solve this condition. 

Note: If the high contrast images exhibit shadows with separate colours, then 
there may be a skew problem which requires a different image adjustment - see 
the ‘Skew adjustment’ section for details.

 

To display a suitable high contrast image

The best way to clearly view the effect of sharpness and brightness adjustments 
is to display a high contrast image, with vertical edges, on the screen. 

•  Open a word processor, type the capital letter 

‘H’, or ‘M’ and increase the point size to 72 or 
higher. For best results, the background should 
be white and the character should be black. 

•  A BLACK shadow on the right of the character 

indicates UNDER compensation.

•  A WHITE shadow on the right of the character 

indicates OVER compensation.  

To use the image controls

1  Simultaneously, press the hotkeys (by default, 

 and 

) along with 

 

to enter configuration mode.

The three keyboard indicators (‘Num Lock’, ‘Caps 
Lock’ and ‘Scroll Lock’) will now begin to flash in 
sequence. The speed of the sequence indicates the 
level of the sharpness adjustment currently applied: 
the slower the rate, the lower the level of sharpness 
being applied.

2  While viewing the displayed high contrast screen image, use the following 

keys to adjust the controls:

High contrast 
black character 
on white 
background

Black or bright 
white shadow 
on the right 
indicates 
the need for 
sharpness 
adjustment

Sharpness:

     for fine adjustment,     for coarse adjustment.

          

There are 255 sharpness levels (one coarse step jumps 10 levels).

    

To autoset sharpness: Press       to make the module calculate  

 

and apply an automatic compensation level - you can use this as a  

 

starting point for your fine tuning.

Note: If the monitor goes blank and switches off (due to 
oversetting the sharpness adjustment) press the   key to restore.

Brightness:

     for adjustment. There are 255 brightness levels.   

3  When no shadows are visible and the displayed images have crisp edges, 

press 

 to exit configuration mode and permanently save all settings.

The new compensation setting will be stored, even when power is removed 
or if a complete reset is initiated. The setting should not require further 
changes unless the cabling arrangement is altered. 

Sharpness
increase 
(coarse) 

Sharpness
decrease 
(coarse) 

Sharpness
increase 
(fine) 

Sharpness
decrease 
(fine) 

Brightness
increase

Brightness
decrease

Restore default 
sharpness and 
brightness
settings 

Exit image 
controls 
and save 
settings 

If the image controls cannot provide a crisp image

If, after adjusting the image controls, the screen image remains 
fuzzy or has coloured shadows you may need to use the Skew 
adjustment feature. Please see the next section for details.

Содержание ServSwitch ACU5114A

Страница 1: ...U S call 724 746 5500 FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com CUSTOMER SUPPORT INFORMATION November 2006 ACU5114A ACU5116A ...

Страница 2: ... configuration mode 14 Password setting 15 Password override 15 Hot plugging and mouse restoration 16 Which restore setting do I use 16 Microsoft and Logitech specific mouse settings 16 Image controls sharpness and brightness 17 Skew adjustment 18 Miscellaneous settings 19 Flash upgrade 20 Stage A Download the upgrade files 20 Stage B Create a startup diskette 20 Copy the downloaded files to the d...

Страница 3: ...tenders allow you to place a duplicate keyboard video monitor mouse audio accessories and a serial device up to 300 metres from a computer system Two users can simultaneously view the output of the host system and either can take control providing it is not being used by the other user A user relinquishes control two seconds after their last key press or mouse movement ACU5114A and ACU5116A varian...

Страница 4: ...lti cable for keyboard video and mouse connections between computer and LOCAL module Serial cable for RS232 connection between computer and LOCAL module CPU KVM SW ITCH VIDEO OUT T O R E M O T E P O W E R Wizard Extender LOCAL 724 746 5500 LOCAL extender module Connection from computer RS232 serial port Optional power supply connection Switch bank to determine certain modes and functions Connectio...

Страница 5: ...ouse and audio connections between computer and LOCAL module Serial cable for RS232 connection between computer and LOCAL module CPU KVM SW ITCH VIDEO OUT T O R E M O T E P O W E R Wizard Extender LOCAL 724 746 5500 LOCAL ACU5116A module Connection from computer RS232 serial port Optional power supply connection Switch bank to determine certain modes and functions Connection to REMOTE module Multi...

Страница 6: ...MIC input on the REMOTE unit LOCAL Switch 4 OFF Normal operation ON Suspend operation and reset the LOCAL module Use this setting momentarily to produce the same effect as removing and restoring power if incorrect operation has occurred Return the switch to the OFF position to allow normal operation to continue Installation The installation of the Wizard extenders is straightforward and can best b...

Страница 7: ...e REMOTE module that the next key to be pressed is a special configuration command for the module and is not to be passed to the computer system 2 OFF 3 OFF Hotkeys CTRL and SHIFT 2 OFF 3 ON Hotkeys ALT and SHIFT 2 ON 3 OFF Hotkeys CTRL and ALT 2 ON 3 ON Hotkeys disabled REMOTE Switch 4 This switch is reserved for future use Note When shipped all switches are set in the OFF positions and this will...

Страница 8: ...t is inserted into the rack therefore check all settings before insertion 1 Place the supplied rack plate s onto the front of the module and secure it with the countersunk screws 2 Orient the module on its side so that its labelled face is the correct way up and the securing plate s is are facing away from the rack 3 Slide the module into the required rack position The rectangular cut out in the f...

Страница 9: ...Speaker or SPK Light green Microphone or MIC Pink or maroon Serial cable connection The Wizard extender modules offer the option to attach an RS232 serial device such as a touch screen input via the remote link The link supports software or hardware handshaking up to a maximum baud rate of 56Kb s To make the serial connection between the LOCAL module and your computer system use the supplied seria...

Страница 10: ... blue D type socket labelled VIDEO OUT on the LOCAL module 2 Connect the keyboard lead to the purple mini DIN socket labelled on the LOCAL module 3 Insert the keyboard lead into the green mini DIN socket labelled on the LOCAL module CPU KVM SW ITCH VIDEO OUT Connection from video monitor Connection from keyboard Connection from mouse LOCAL LOCAL Optional power connector not required unless the hos...

Страница 11: ... connector from the twisted pair cable link into the socket marked TO LOCAL 2 Attach the output connector of the power supply to the socket at the front edge of the REMOTE module labelled POWER 3 If a serial connection is to be used attach the lead from your serial device to the 9 way male connector on the REMOTE module labelled Power supply connection 1 Insert the IEC connector of the supplied po...

Страница 12: ...rophone LOCAL switch 3 ON stereo line in 1 Connect the microphone or stereo line input plug to the REMOTE module socket labelled Note Ensure that the setting of switch 3 on the LOCAL module matches the input to this socket OFF microphone ON stereo line input 2 Connect the speaker plug to the socket labelled Note When the REMOTE module is rack mounted the audio connections must be made after the mo...

Страница 13: ...deo monitors continuously receive the output from the host system Control of the host system is arbitrated by the Wizard extender modules on a first come first served basis In the idle state control is available to both users and their keyboard indicators both show the current Num Lock etc conditions of the host system At the moment that a key is pressed or a mouse is moved the keyboard and mouse ...

Страница 14: ...and the three keyboard indicators will begin alternately flashing between the Num Lock and Scroll Lock and Caps Lock This sequence indicates that a password is required To unlock the system 1 Enter the correct password and press Note Passwords are NOT case sensitive Note If an invalid password has been entered and the keyboard indicators are not flashing as described above press to clear the incor...

Страница 15: ...eeded for computer tasks you can change them for another combination using switches 2 and 3 on the REMOTE module 2 OFF 3 OFF Hotkeys and default setting 2 OFF 3 ON Hotkeys and 2 ON 3 OFF Hotkeys and 2 ON 3 ON Hotkeys disabled Entering using and exiting configuration mode To enter and use configuration mode 1 Simultaneously press the currently configured hotkeys by default and along with The three ...

Страница 16: ...d unlocking the system section in the Installation and operation chapter Password override This mode allows you to override the password that has been set at the REMOTE module and place it into configuration mode so that a new one may be set This feature is particularly useful when passwords have been lost or forgotten To override the REMOTE password 1 Remove power from the REMOTE module 2 With po...

Страница 17: ...ally state that it is an Intellimouse on its underside label Recognising an Intellimouse driver Before hot plugging your Wizard extender modules or afterwards using only keyboard control access the Windows Control Panel and select either the Mouse option on Windows NT 2000 and XP or the System option on Windows 95 98 ME Look for the name of the driver which will usually include the words PS 2 or I...

Страница 18: ...o flash in sequence The speed of the sequence indicates the level of the sharpness adjustment currently applied the slower the rate the lower the level of sharpness being applied 2 While viewing the displayed high contrast screen image use the following keys to adjust the controls High contrast black character on white background Black or bright white shadow on the right indicates the need for sha...

Страница 19: ...tern it is much easier to discover which if any colours are being adversely affected by the twisted pair cable run 4 As appropriate press either the R G or B keyboard keys to select the appropriate colour channel Corresponding keyboard indicators will flash rapidly to show which channel is currently selected for adjustment Num Lock for Red Caps Lock for Green and Scroll Lock for Blue Convergence t...

Страница 20: ...ning an application that can display typed keys as screen characters e g a word processor or Windows Notepad The current firmware version will be written to the application in the form of the letter V followed by three numbers for example V201 means version 2 01 Reset all configuration options to default states Returns all user configurable options to the settings that are installed at manufacture...

Страница 21: ...sed by the SSWExxx EXE to select the appropriate one SSWExxxD HEX this is the firmware file for the LOCAL module SSWExxxR HEX this is the firmware file for the REMOTE module Where xxx is the upgrade version number Now please follow Stage B Stage B Create a startup diskette For this stage you will need a 31 2 floppy diskette that is either blank or has existing contents that are no longer required ...

Страница 22: ...t of the computer Connect the other end of the cable to the keyboard port of the REMOTE module This is the only connection required 3 On the REMOTE module change switch 1 to the ON position 4 Attach the power supply unit to the POWER input of the REMOTE module and connect the mains lead to a nearby wall socket 5 Switch on the computer The upgrade process will start automatically and confirmation w...

Страница 23: ...ontrol is set too high the monitor may not be able to display a picture Try reinstating the factory default sharpness settings Please refer to the Image controls sharpness and brightness section in the Special Configuration chapter Temporarily disconnect the video link to the LOCAL module connect a monitor directly to the computer video port and check for a correct video image output The keyboard ...

Страница 24: ...tal ampere rating of all the devices plugged into the wall outlet does not exceed the wall outlet s ampere rating Do not attempt to service the Wizard modules yourself The Wizard modules and power supplies can get warm in operation do not situate them in an enclosed space without any ventilation The Wizard modules do not provide ground isolation and should not be used for any applications that req...

Страница 25: ...etween the equipment and the receiver c Connect the equipment to an outlet on a circuit different from that to which the receiver is connected d Consult the supplier or an experienced radio TV technician for help FCC Compliance Statement United States This equipment generates uses and can radiate radio frequency energy and if not installed and used properly that is in strict accordance with the ma...

Страница 26: ...Repairs to certified equipment should be made by an authorized Canadian maintenance facility in this case your supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for their own protection that the electrical ground connections of the power u...

Страница 27: ...por los orificios de ventilación 10 El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u otros aparatos incluyendo amplificadores que producen calor 11 El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación o como se indique en el aparato 12 Precaución debe ser tomada...

Страница 28: ...01 888 800 358 201 888 808 tuki blackbox fi France www blackbox fr 33 1 45 606 717 33 1 45 606 747 tech blackbox fr Germany www black box de 49 811 5541 110 49 811 5541 499 techsupp black box de Ireland www blackbox co uk 353 1 662 2466 353 1 662 2477 techhelp blackbox co uk Italy www blackbox it 39 02 27 404 700 39 02 27 400 219 supporto tecnico blackbox it Netherlands www blackbox nl 31 30 241 7...

Страница 29: ... ctxd com Documentation by 2006 Black Box Corporation All trademarks are acknowledged Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 United States of America Tel 1 724 746 5500 Fax 1 724 746 0746 ...

Страница 30: ... NETWORK SERVICES Copyright 2006 Black Box Corporation All rights reserved 1000 Park Drive Lawrence PA 15055 1018 724 746 5500 Fax 724 746 0746 ...

Отзывы: