48
SCAN-LAN 80 CABLE SCANNER
Press the
▼
or
▲
button to enable or disable the
audible tone.
Press the Enter button to store the audible-tone
setting.
6.4 Fault Threshold
The fault threshold is the minimum reflection level
detected as an anomaly in the AUTOTEST or
LENGTH test. Any reflections less than this
threshold will be ignored by the Scan-LAN 80.
The threshold is expressed as a percentage of the
incident test pulse.
The currently selected fault threshold will be shown
in the display. The default value is 7%, which
corresponds to the worst-case allowable impedance
mismatch specified in IEEE 802.3 for coax cable.
Anomalies greater than this threshold may impair
network transmission.
▼
or
▲
and ENTER
Audible Tone:
Enabled
Содержание Scan-LAN 80
Страница 19: ...15 CHAPTER 3 Cable Tests Wiring 1 2 3 6 1 2 3 6 4 5 7 8 4 5 7 8 1 2 Open 3 6 Straight Thru 4 5 Open 7 8 Open...
Страница 22: ...18 SCAN LAN 80 CABLE SCANNER Wiring 1 2 3 6 1 2 3 6 4 5 7 8 4 5 7 8 1 2 Reversed 3 6 Reversed 4 5 Open 7 8 Open...
Страница 48: ...44 SCAN LAN 80 CABLE SCANNER Figure 5 1 Connecting Unterminated Cable 50 MINIMUM LENGTH...