30
SCAN-LAN 80 CABLE SCANNER
Cable Length
is displayed in either feet or meters
on the top line of the display. If the length fails
to meet IEEE specifications, the length display
will blink.
The units of length may be changed with the
Special Setup function. See
Chapter 6
.
No Reflections
will be displayed on the top line
if the cable is terminated properly and no cable
anomalies are present.
Terminator
value in ohms is displayed. A
flashing “Terminator” indicates a bad
terminator. If the termination resistance is
outside the range of the Scan-LAN 80, “OPEN”
will be displayed.
Impedance
value in ohms is displayed. A flashing
impedance value indicates a characteristic
impedance value that does not meet
specifications for the selected cable type. If the
measured impedance is outside the range of
the Scan-LAN 80, “OPEN” will be displayed.
Length
153'
Terminator
51
Ω
Impedance
49
Ω
OK for Thinnet
Содержание Scan-LAN 80
Страница 19: ...15 CHAPTER 3 Cable Tests Wiring 1 2 3 6 1 2 3 6 4 5 7 8 4 5 7 8 1 2 Open 3 6 Straight Thru 4 5 Open 7 8 Open...
Страница 22: ...18 SCAN LAN 80 CABLE SCANNER Wiring 1 2 3 6 1 2 3 6 4 5 7 8 4 5 7 8 1 2 Reversed 3 6 Reversed 4 5 Open 7 8 Open...
Страница 48: ...44 SCAN LAN 80 CABLE SCANNER Figure 5 1 Connecting Unterminated Cable 50 MINIMUM LENGTH...