44
Power Switch Cabinet 4-port New Generation
Controlling Power Outlets
Only Power Outlets which have been selected can be controlled over the Hidden Page. To select Power Outlets,
go to the "Settings/Accounts" page and edit the Hidden Page Account. In the Inputs/Outputs field, selected the
Power Outlets you want to control and click on the Arrow button next to the Inputs/Outputs field. The selected
Power outlets appear in the right field, click on Apply Change to validate the configuration.
Example: if you have selected all 4 power Outlets and the IP address of your Power Switch is 192.168.100.200,
type in:
http://192.168.100.201/hidden.htm
followed by <ENTER>.
Your Web browser will now display:
Hidden Page
Date
Version
M0:O1=On
M0:O2=On
M0:O3=On
M0:O4=On
Each Power Outlet support individually 3 commands: On, Off and Restart using following syntax:
M0:Ox=[ON], [OFF], [RESTART]
M0: ID of your Power Switch
Ox: Outlet number of your Power Switch
ON: ON command
OFF: OFF command
RESTART: Restart command
The first command must be preceded by a "?"
Commands can be concatenated using the character "&"
Commands can be specified in upper case, lower case or mixed case
Example: if you want to switch to OFF the Power Outlet #1 and 3, type in:
http://192.168.100.201/hidden.htm?M0:O1=OFF&M0:O3=OFF
Your Web browser will now display:
Hidden Page
Date
Version
M0:O1=Off
M0:O2=On
M0:O3=Off
M0:O4=On