![Black Box LS1016A Скачать руководство пользователя страница 300](http://html.mh-extra.com/html/black-box/ls1016a/ls1016a_user-manual_2763435300.webp)
Appendix B - Cabling, Hardware, & Electrical
300
BLACK BOX
®
Advanced Console Server
The RS-232 Standard
RS-232C, EIA RS-232, or simply RS-232 refer to a standard defined by the Electronic Industries
Association in 1969 for serial communication. More than 30 years later, more applications
have been found for this standard than its creators could have imagined. Almost all electronic
devices nowadays have serial communication ports.
RS-232 was defined to connect Data Terminal Equipment, (DTE, usually a computer or termi-
nal) to Data Communication Equipment (DCE, usually a modem):
DTE > RS-232 > DCE > communication line > DCE > RS-232 > DTE
RS-232 is now mostly being used to connect DTE devices directly (without modems or com-
munication lines in between). While that was not the original intention, it is possible with
some wiring tricks. The relevant signals (or wires) in a RS-232 cable, from the standpoint of
the computer (DTE), are:
Not all signals are necessary for every application, so the RS-232 cable may not need all 7
wires. The RS-232 interface defines communication parameters such as parity, number of bits
per character, number of stop-bits and the baud rate. Both sides must be configured with the
same parameters. That is the first thing to verify if you think you have the correct cable and
things still do not work. The most common configuration is 8N1 (8 bits of data per character,
no parity bit included with the data, 1 stop-bit to indicate the end of a character). The baud
rate in a RS-232 line translates directly into the data speed in bits per second (bps). Usual
Receive Data (RxD) and
Transmit Data (TxD)
The actual data signals
Signal Ground (Gnd)
Electrical reference for both ends
Data Terminal Ready (DTR)
Indicates that the computer (DTE) is active
Data Set Ready (DSR)
Indicates that the modem (DCE) is active.
Data Carrier Ready (DCD)
Indicates that the connection over the
communication line is active
CTS (Clear to Send, an input)
Flow control for data flowing from DTE to DCE
RTS (Request to Send, an output)
Flow control for data flowing from DCE to DTE
Содержание LS1016A
Страница 12: ...Table of Contents 12 BLACK BOX Advanced Console Server This page has been left intentionally blank ...
Страница 30: ...Introduction and Overview 30 BLACK BOX Advanced Console Server This page has been left intentionally blank ...
Страница 282: ...Time Zone 282 BLACK BOX Advanced Console Server This page has been left intentionally blank ...
Страница 406: ...Appendix H Web User Management 406 BLACK BOX Advanced Console Server Figure 43 Access Limit List default page ...
Страница 414: ...Appendix H Web User Management 414 BLACK BOX Advanced Console Server This page has been left intentionally blank ...
Страница 439: ...List of Figures User Guide 439 47 Terminal Server diagram 422 48 Ports configured for Dial in Access 424 ...
Страница 440: ...List of Figures 440 BLACK BOX Advanced Console Server This page has been left intentionally blank ...
Страница 449: ...This page has been left intentionally blank ...