Black Box LMC5203A Скачать руководство пользователя страница 18

Chapter 3: Install the High-Density Media Converter System II 

Page 18 

877-877-2269   |   blackbox.com

LMC5208A

3.2 Installing the 6-Slot Rackmount Chassis 

Install the chassis first before installing any modules into a 6-Slot 

Rackmount/Desktop Chassis. When installing the chassis, observe the 

following precautions to prevent electrical or mechanical damage: 
1.  Protect the chassis from exposure to sunlight and electrical or magnetic 

fields.

2.  Make sure that the equipment rack remains stable, even with the addition 

of the chassis and its associated cabling. 

To install a 6-Slot Rackmount/Desktop Chassis: 

1.  Have four #10 screws and four clip nuts available (hardware may vary 

depending on rack type).  The rest of the hardware is supplied with the unit.  

2.  Locate a suitable location in the rack for installation and secure the clip-

nuts onto the mounting rails.  Use screws to attach the chassis to the rack.   

3.  Plug the chassis into a reliable, filtered power source. 
4.  Elevated Operating Ambient - If installed in a closed or multi-unit rack 

assembly, the operating ambient temperature of the rack environment may 

be greater than room ambient. Install the equipment in an environment that 

is compatible with the maximum ambient temperature (Tma) specified by 

Black Box.  

5.  Reduced Air Flow - Install the equipment in a rack so that the amount of air 

flow required for safe operation of the equipment is not compromised.  

6.  Mechanical Loading - Mount the equipment in the rack so that a hazardous 

condition is not achieved due to uneven mechanical loading.  

7.  Circuit Overloading - Consideration should be given to the connection of 

the equipment to the supply circuit and the effect that overloading of the 

circuits might have on over current protection and supply wiring.  

8.  Reliable Grounding - Maintain reliable grounding of rackmounted 

equipment. Give particular attention to supply connections other than direct 

connections to the branch circuit (e.g., use of power strips). 

9.  All AC and DC versions are intended for use in a Restricted Access 

Location (RAL). 

Chapter 3: Install the High-Density Media Converter System II 

LMC5208A 

724-746-5500   |   blackbox.com

Page 15 

3. 

A suitable listed circuit breaker shall be provided in the building 

installation as the unit's disconnect device.  The branch circuit rating (i.e. 

minimum 15A listed circuit breaker, etc.). 

DC Power Supply Module Wiring Instructions 

The following diagram shows the wiring configuration for a -48 VDC power 

supply module for the 20-Slot Rackmount Chassis 2DC and ACDC. 

NOTE

The chassis is protected against incorrect wiring configurations.  When wired 

incorrectly, the chassis will not function, but no damage will occur.

3.1.2  Installing SNMP Management and Application Modules 

To install a module: 
1.  Remove the blank bracket (if present) covering the slot where the module 

will be installed.  Black Box recommends installing blank brackets in 

unused module slots. 

2.  Slide the module into the chassis using the card guides. 
3.  Secure the module to the chassis by tightening the captive screw.  (Refer to 

the documentation shipped with the module for configuration information.) 

4.  When installing modules, observe ESD precautions (refer to Chapter 7, 

Electrostatic Discharge Precautions). 

To manage a 20-Slot Rackmount Chassis, install the SNMP Management 

Module in the appropriate slot of the chassis.    

  Install the 20-Slot Rackmount Chassis SNMP Management Module into the 

first slot of the chassis. 

NOTE

This slot is ONLY for the Management Module; do not install Application Modules such 

as media conversion and mode conversion modules in this slot.

Содержание LMC5203A

Страница 1: ...LMC5234A LMC5227A LMC5208A R2 LMC5203A LMC5206A LMC5235A LMC5227A R2 LMC5204A LMC5233A LMC5236A High Density Media Converter System II Choose from a wide variety of chassis and modules to build a powe...

Страница 2: ...aux appareils num riques de la classe A prescrites dans le R glement sur le brouillage radio lectrique publi par le Industrie Canada Class B Digital Device This equipment has been tested and found to...

Страница 3: ...radio noise emission from digital apparatus set out in the Radio Interference Regulation of Industry Canada Product Description Version FCC Class A FCC Class B Dual AC 9 Dual DC 9 20 Slot Rackmount C...

Страница 4: ...er ser referido a personal de servicio calificado 9 El aparato el ctrico debe ser situado de tal manera que su posici n no interfiera su uso La colocaci n del aparato el ctrico sobre una cama sof alfo...

Страница 5: ...no sean derramados sobre la cubierta u orificios de ventilaci n 18 Servicio por personal calificado deber ser provisto cuando a El cable de poder o el contacto ha sido da ado u b Objectos han ca do o...

Страница 6: ...of separately from regular household waste It is the consumer s responsibility to dispose of this and all equipment so marked through designated collection facilities appointed by government or local...

Страница 7: ...Power Supply Modules 16 3 2 Installing the 6 Slot Rackmount Chassis 18 3 2 1 DC Power Wiring Replacing Power Supply and Fans 19 3 2 2 Installing Management and Application Modules 20 3 3 Installing t...

Страница 8: ...12A R2 Power Supply Module for LMC5208A R2 LMM090 Serial Cable for SNMP DB9 Male to DB9 Female 6 Slot Rackmount Desktop Chassis Part Number Description LMC5200A SNMP Management Module LMC5203A 6 Slot...

Страница 9: ...mbers LMC5208A 877 877 2269 blackbox com Page 9 Back Up Spares Sold Separately Part Number Description LMC5200A SNMP Management Module includes Black Box and View LMC5238A 19 inch Rackmount shelf and...

Страница 10: ...ity 20 to 90 non condensing at 40 C 104 F Shipping Weight 25 lbs 11 3 kg Dimensions 5 2 H x 19 0 W x 13 8 D 13 21cm x 48 26cm x 35 05cm 1 2 6 Slot Rackmount Desktop Chassis Specifications Input Specif...

Страница 11: ...40 F to 122 F Storage Temperature AC 40 C to 85 C 40 F to 185 F DC 55 C to 125 C 67 F to 257 F Humidity 5 95 non condensing 0 10 000 ft altitude Shipping Weight 5 lbs 2 3 kg Dimensions 1 73 H x 7 45 W...

Страница 12: ...swappable 20 Slot Rackmount Chassis Features The 20 Slot Rackmount Chassis models are available in dual AC dual DC and ACDC versions It offers features such as end user replaceable power supply module...

Страница 13: ...Chassis is a 1U high rackmountable chassis that can use redundant power supply modules and supports a SNMP Management Module 3 Slot Desktop Chassis Features The 3 Slot Desktop Chassis series offers a...

Страница 14: ...ronment that is compatible with the maximum ambient temperature Tma specified by Black Box 5 Reduced Air Flow Install the equipment in a rack so that the amount of air flow required for safe operation...

Страница 15: ...n Modules To install a module 1 Remove the blank bracket if present covering the slot where the module will be installed Black Box recommends installing blank brackets in unused module slots 2 Slide t...

Страница 16: ...upply module 1 Disconnect the power source from the power supply module 2 Remove the screws of the retainer plate on some AC modules 3 Move the Power Supply Release switch toward the right or unscrew...

Страница 17: ...8A Redundant ACDC Power Supply Close Up Power Supply Module 1 PS1 Power Supply Module 2 PS2 PS Release Screw PS Release Screw Reset Alarm Switch DC Power Connector PS1 Status LED AC Power Connector PS...

Страница 18: ...into a reliable filtered power source 4 Elevated Operating Ambient If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than r...

Страница 19: ...isconnect the power source from the power supply 2 Move the Power Supply Release switch toward the right and hold while grasping the power supply module by the silver handle 3 Slide out of the chassis...

Страница 20: ...nto the first slot on the far left of the chassis NOTE This slot is ONLY for the Management Module do not install Application Modules such as media conversion and mode conversion modules in this slot...

Страница 21: ...assis and then hang the unit on the screws 6 All versions are intended for use in a Restricted Access Location RAL 7 A readily accessible disconnect device shall be incorporated in the building instal...

Страница 22: ...o not activate contact Black Box Fans are not end user replaceable The red Alarm Reset Button also functions as a Fan Test button To verify fan functionality hold the button down for several seconds t...

Страница 23: ...877 877 2269 blackbox com Page 23 Install the 3 Slot Desktop Chassis SNMP Management Module into the bottom left slot NOTE This slot is ONLY for the Management Module do not install Application Modul...

Страница 24: ...supply module itself also indicate power supply module failures Last Gasp Alarm The 20 Slot Rackmount Chassis includes the Last Gasp trap feature Remote Chassis Down which sends a Trap when the follo...

Страница 25: ...functions are LNK ACT FDX COL TEMP PS FAN A FAN B Glows green when a link is established on port Blinks green when data activity occurs Glows yellow when port is in Full Duplex mode Blinks yellow whe...

Страница 26: ...the specified level the SNMP agent sends a trap configured in iView to the administrator There is also an LED indicator on the SNMP Management Module for chassis temperature 4 2 2 SNMP Write Lock Ther...

Страница 27: ...ding on the model Fans are included in all models Alarm Reset Button When one power supply module malfunctions an audible alarm sounds indicating the loss of the power supply The alarm can be silenced...

Страница 28: ...P management board The SNMP Management Module can be removed and replaced as necessary Refer to the SNMP Management Module manual for complete instructions about how to configure and operate If an SNM...

Страница 29: ...l free in the U S Call 877 877 BBOX outside U S call 724 746 5500 Free technical support 24 hours a day 7 days a week Call 877 877 2269 or Fax 724 746 0746 Mail order Black Box Corporation 1000 Park D...

Страница 30: ...quality components can cause many hard to diagnose problems in an installation 2 Dust caps are installed at Black Box to ensure factory clean optical devices These protective caps should not be remov...

Страница 31: ...dule or component If the wrist strap is not available maintain grounded contact with the system unit throughout any procedure requiring ESD protection 3 Hold the units by the edges do not touch the el...

Страница 32: ...LMC5208A Rev 2 50 80954BB 01 B1...

Отзывы: