Chapter 3: Install the High-Density Media Converter System II
Page 20
724-746-5500 | blackbox.com
LMC5208A
3.2.2 Installing Management and Application Modules
Installing Applications Modules
To install a module:
1. Remove the blank bracket (if present) covering the slot where the module
will be installed. Black Box recommends installing blank brackets in
unused module slots.
2. Slide the module into the chassis using the card guides.
3. Secure the module to the chassis by tightening the captive screw. (Refer to
the documentation shipped with the module for configuration information.)
4. When installing modules observe ESD precautions; refer to Chapter 7,
Electrostatic Discharge Precautions.
To manage a 6-Slot Rackmount/Desktop Chassis, install the SNMP
Management Module in the appropriate slot of the chassis.
•
Install the 6-Slot Rackmount/Desktop Chassis SNMP Management Module
into the first slot on the far left of the chassis.
NOTE
This slot is ONLY for the Management Module; do not install Application Modules such
as media conversion and mode conversion modules in this slot.
3.3 Installing the 3-Slot Desktop Chassis
Install the chassis first before installing any modules into a 3-Slot Desktop
Chassis.
When installing the chassis, be sure to observe the following precautions to
prevent electrical or mechanical damage:
1. Stay within the chassis’ power rating to prevent overload of supply circuits
or damage to any overcurrent protection and supply wiring.
2. Maintain reliable ground, especially when connecting to a power strip
instead of directly to a branch circuit.
3. Protect the chassis from exposure to sunlight and electrical or magnetic
fields.
4. Make sure that the equipment rack remains stable, even with the addition
of the chassis and its associated cabling.
Use the 3-Slot Desktop Chassis. as a table-top chassis, mount in a Rackmount
shelf, or mount it to a wall surface.
1. Install the 3-Slot Desktop Chassis by placing it on a flat surface.
Chapter 2: Overview
LMC5208A
877-877-2269 | blackbox.com
Page 13
2.3 The 3-Slot Desktop Chassis
The 3-Slot Desktop Chassis series is a modular chassis platform designed for
use with Black Box Simple Network Management Protocol (SNMP)
manageable series of modules. The 3-Slot Desktop Chassis is a 1U high,
rackmountable chassis that can use redundant power supply modules, and
supports a SNMP Management Module.
3-Slot Desktop Chassis Features
The 3-Slot Desktop Chassis series offers a line of models including single AC,
single DC, dual AC, dual DC and ACDC version. All contain internal fixed
power supply modules that are not end-user replaceable. It offers features
such as redundant power supply modules, temperature monitoring, Last Gasp,
and an Alarm Reset Button.
Содержание LMC5203A
Страница 32: ...LMC5208A Rev 2 50 80954BB 01 B1...