Chapter 3: Install the High-Density Media Converter System II
Page 16
877-877-2269 | blackbox.com
LMC5208A
3.1.3 Replacing Power Supply Modules
User-Replaceable Power Supply Modules
While power supply modules are redundant, you should promptly replace failed
power supply modules to maintain network integrity and prevent data loss.
To replace a power supply module:
1. Disconnect the power source from the power supply module.
2. Remove the screws of the retainer plate (on some AC modules).
3. Move the Power Supply Release switch toward the right or unscrew captive
release screw.
4. Before grasping the power supply module by the silver handle, press the
release screw and then slide out of the chassis (Power supply modules are
hot-swappable).
5. Install a new power supply module. If module is equipped with an ON/OFF
switch install the module with the switch in the OFF position.
Dual AC, Part Number LMC5207A-R2
Chapter 3: Install the High-Density Media Converter System II
LMC5208A
724-746-5500 | blackbox.com
Page 17
Dual DC, Part Number LMC5208A-R2
NOTE
Do not mix AC and DC power supply modules.
ACDC, Part Number LMC5228A
Redundant ACDC Power Supply, Close-Up
Power
Supply
Module
1 (PS1)
Power
Supply
Module
2 (PS2)
PS
Release
Screw
PS
Release
Screw
Reset
Alarm
Switch
DC Power
Connector
PS1
Status
LED
AC Power
Connector
PS2 Status
LED
NOTE
For LMC5228A 20-Slot Rackmount Chassis, all models in that model number series
can support Dual AC, Dual DC or ACDC. The power supply modules for that model
number series are interchangeable.
Содержание LMC5203A
Страница 32: ...LMC5208A Rev 2 50 80954BB 01 B1...