background image

11

1.877.877.2269

BLACKBOX.COM

CHAPTER 5: CLIENT INSTALLATION

OR 

4b. Select WOL & Shutdown Link Speed “No Speed Down“ as shown in Figure 5-3.

FIGURE 5-3. PROPERTIES SCREEN

5. Select the Power Management Setting.

FIGURE 5-4. POWER MANAGEMENT TAB

NEED HELP?

LEAVE THE TECH TO US

LIVE 24/7

TECHNICAL

SUPPORT

1.877.877.2269

Содержание LH1690C-LC-R3

Страница 1: ...USER MANUAL 24 7 TECHNICAL SUPPORT AT 1 877 877 2269 OR VISIT BLACKBOX COM LH1690C LC R3 NETWORK INTERFACE ADAPTER PCIE ...

Страница 2: ...DWARE INSTALLATION 6 4 OPERATION 8 4 1 LED Indicator Description 8 4 2 Wake On LAN WOL 8 5 CLIENT INSTALLATION 10 APPENDIX A REGULATORY INFORMATION 12 A 1 FCC Statement 12 A 2 NOM Statement 13 APPENDIX B DISCLAIMER TRADEMARKS 14 B 1 Disclaimer 14 B 2 Trademarks Used in this Manual 14 NEED HELP LEAVE THE TECH TO US LIVE 24 7 TECHNICAL SUPPORT 1 877 877 2269 ...

Страница 3: ...s GROUNDING METHODS The following measures help to avoid electrostatic damages to the device 5 Cover workstations with approved antistatic material Always wear a wrist strap connected to a properly grounded workplace 6 Use antistatic mats heel straps and or air ionizers for more protection 7 Always handle electrostatically sensitive components by their edge or by their casing 8 Avoid contact with ...

Страница 4: ...ot PCI e 1 1 compliant Power From the PCI e bus maximum 1 32 W 3 3 VDC at 0 4 A Software Supported Microsoft Windows XP Vista Server 2008 R2 Windows 7 Windows 8 8 1 Server 2012 Novell Netware 5 x 6 x Server Novell Netware DOS Client for ODI 16 bit NDIS2 driver Support DOS MS client Lantastic Lanman Norton Ghost Linux driver for kernel up to 4 7 FreeBSD 7 x and 8 0 driver Dimensions Card only 4 5 x...

Страница 5: ... with IEEE 802 3z 1000BASE X fiber interface Operates in full duplex mode Uses ieee 802 3x full duplex flow control Has 1 PCI e bus complies with PCIe rev 1 1 interface Supports jumbo frame Offers high level VLAN filtering Supports IP headers and TCP UDP checksums offload On board screening of VLAN tagged ethernet frames Supports Wake On LAN Complies with RoHS standard 2 3 WHAT S INCLUDED Your pac...

Страница 6: ...from the power outlet and that you have followed proper electrical grounding procedures 1 High voltage inside the system presents a safety hazard Make sure the power is off before removing the cover 2 Remove the system cover and select any empty PCIe slot See Fig 3 1 NOTE If you do not know how to identify a PCIe slot refer to your system documentation FIGURE 3 1 REMOVE THE SYSTEM S COVER 3 Select...

Страница 7: ...charge precautions when installing the network adapter card in a system Failure to observe this caution could result in damage to the card 5 Applying even pressure at both corners of the card push the adapter card until it is firmly seated in the PCIe slot Make sure the card is securely seated FIGURE 3 3 INSTALLING THE CARD IN A PCIE SLOT 6 Replace the system s cover and secure it with the screws ...

Страница 8: ...en traffic is present FDX Green Lights when full duplex mode is active 4 2 WAKE ON LAN WOL The Wake on LAN function on this adapter can recognize a wake up frame and signal the PC to power up FIGURE 4 1 WAKE ON LAN VERIFY BIOS SUPPORT SCREEN If the PC s motherboard supports WOL and PCIe the Wake up Link connector is not necessary To disable the WOL function Default Set WOL jumper J1 to the OFF pos...

Страница 9: ... 2 LOCATION OF JUMPER J1 ON THE ADAPTER To enable the WOL function Set the WOL jumper J1 to the ON position 1 2 3 J1 ON OFF Default WoL 1 2 3 J1 ON OFF WoL FIGURE 4 3 JUMPER J1 SETTINGS NEED HELP LEAVE THE TECH TO US LIVE 24 7 TECHNICAL SUPPORT 1 877 877 2269 ...

Страница 10: ...re the network adapters as shown in Figures 5 1 through 5 4 3 Double click on Realtek PCIe GBE Family Controller in the Device Manager screen FIGURE 5 1 DEVICE MANAGER SCREEN 4 The Properties screen appears 4a Select Shutdown Wake on LAN Enabled as shown in Figure 5 2 FIGURE 5 2 PROPERTIES SCREEN NEED HELP LEAVE THE TECH TO US LIVE 24 7 TECHNICAL SUPPORT 1 877 877 2269 ...

Страница 11: ...LLATION OR 4b Select WOL Shutdown Link Speed No Speed Down as shown in Figure 5 3 FIGURE 5 3 PROPERTIES SCREEN 5 Select the Power Management Setting FIGURE 5 4 POWER MANAGEMENT TAB NEED HELP LEAVE THE TECH TO US LIVE 24 7 TECHNICAL SUPPORT 1 877 877 2269 ...

Страница 12: ...ollowing measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult an experienced radio TV technician for help CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user s autho...

Страница 13: ...quipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u otros aparatos incluyendo amplificadores que producen calor 11 El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación o como se indique en el aparato 12 Precaución debe ser tomada de tal manera que la tierra fisica y la...

Страница 14: ...product information or specifications set forth in this docu ment and Black Box Corporation may revise this document at any time without notice B 2 TRADEMARKS USED IN THIS MANUAL Black Box and the Black Box logo type and mark are registered trademarks of Black Box Corporation Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners NEED HELP LEAVE T...

Страница 15: ...15 1 877 877 2269 BLACKBOX COM NOTES NEED HELP LEAVE THE TECH TO US LIVE 24 7 TECHNICAL SUPPORT 1 877 877 2269 ...

Страница 16: ... COPYRIGHT 2022 BLACK BOX CORPORATION ALL RIGHTS RESERVED LH1690C LC R3_USER_REV1 PDF NEED HELP LEAVE THE TECH TO US LIVE 24 7 TECHNICAL SUPPORT 1 877 877 2269 ...

Отзывы: