Black Box Ethernet Extenders
error counters:
crc: 0
losw: 0
LB532A-M> exit
NOTE: The line probe feature is a future product enhancement.
3. INSTALLATION
Once the LB532A-M is properly configured, it is ready to connect to the line interface
and to the power source. This section explains how to make these connections.
Figure 3.
LB532A-M front panel connectors
3.1 CONNECTING THE INTERFACE
The LB532A-M supports communication between two DTE devices using 24 AWG
(0.5 mm) wire up to:
• 18,000 feet (3.4 miles or 5.48 km) at 192 kbps per hop
• 11,000 feet (2.2 miles or 3.5 km) at 5696 kbps per hop
Two things are essential:
1. These units work in pairs with any LB532A-L, LB532A-R, LB512A-L or LB512A-
R model. Every local line port should connect to a remote line port.