Page 25
724-746-5500 | blackbox.com
Chapter 7: Network Configuration
7.4 Administration > Power Management
Where you have a Serial Remote Power Switch (SRPS), connect it to the RPS
port of the ServSwitch Multiuser.
NOTE: The Serial Remote Power Switch (SRPS) port is not supported with the
currently released firmware at the time of this writing. This port is
reserved for future use.
Configure the Power Management switch as follows:
1. From the menu, click Power Management. The Power Management window
appears, see Figure 7-4.
Server Name
Managed by Sockets
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
Administration > Power Management
Network
Configuration
Administration
User Settings
Switch Configuration
Power Management
User Targets
Security
Settings
SSL Certificate
Maintenance
2x16 Switch Upgrade
SAMs Upgrade
Restore Factory Settings
Set Time & Date
Backup & Restore
Logout
Restart
Number of
Sockets:
24
Seria
PDU Type:
Figure 7-4. Power Management screen.
2. Select the number of sockets on the power management switch in the Number
of Sockets drop-down menu (SRPS has 8).
3. Click on the Apply button. The appropriate number of Managed by Sockets and
Server Name drop-down menus appear.
4. Select the PDU type (default is SRPS).
5. Match the sockets to the servers. For each socket, select the server name
connected to it from the drop-down menu.
When there is a double or triple power supply, you need to assign multiple
sockets to the same KVM port.