background image

9

CHAPTER 2: Introduction

2. Introduction

Thank you for choosing the Conference 1 Phone. It incorporates technology that
allows for 360-degree dynamic audio pickup. As it does so, it will track the direction
of the speaker’s voice, lighting the nearest LEDs to let you know you’re being
heard at the locations you’ve called. The Conference 1 also features the most
advanced echo cancellation available in a conference phone, as well as superior
background-noise reduction. It is full-duplex—its speakers and microphones
operate simultaneously—so you can both listen and speak at the same time.

The rest of this manual describes how to install and use your Conference 1.

Please pay particular attention to the electrical-safety precautions listed in

Section 3.3

. If after reading this manual you still have questions about any of the

phone’s functions or components, feel free to call Black Box Technical Support as
described in 

Chapter 5

.

Содержание CONFERENCE 1 PHONE

Страница 1: ...de U S call 724 746 5500 FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site...

Страница 2: ...aged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment int...

Страница 3: ...ny may make changes in its technical operations and procedures If any such changes affect the compatibility or use of this device the telephone company is required to give adequate notice of the chang...

Страница 4: ...certified equipment should be made by an authorized Canadian maintenance facility in this case Black Box Any repairs or alterations made by the user to this equipment or equipment malfunctions may gi...

Страница 5: ...arato el ctrico debe ser montado a la pared o al techo s lo como sea recomendado por el fabricante 8 Servicio El usuario no debe intentar dar servicio al equipo el ctrico m s all a lo descrito en las...

Страница 6: ...r una antena externa deber ser localizada lejos de las lineas de energia 16 El cable de corriente deber ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo 17 Cuidado deb...

Страница 7: ...3 4 4 Connecting to a Modem 19 3 4 5 Connecting to a Two Line Telephone Service 21 3 4 6 Connecting to a Digital Telephone System 23 3 4 7 Connecting to an Audio Recording Device 25 4 Operation 26 4...

Страница 8: ...wire lines as well as extension lines from PBXes although additional equipment will be required for anything but standard phone lines Operation Full duplex User Controls Bottom mounted pulse tone slid...

Страница 9: ...ty Tolerance Operating 50 to 80 noncondensing Storage 10 to 90 noncondensing Enclosure High impact plastic Power From outlet through special UL and cUL approved power supply and attached line cords In...

Страница 10: ...nced echo cancellation available in a conference phone as well as superior background noise reduction It is full duplex its speakers and microphones operate simultaneously so you can both listen and s...

Страница 11: ...tereo plug and the other end has two mini stereo plugs This manual If anything s missing contact Black Box However the manufacturer and their authorized agents are not responsible for any damage that...

Страница 12: ...ngerous voltage points or short out parts which could also pose a risk of fire or electric shock Try not to spill liquid of any kind on your Conference 1 s base unit or power supply If this ever happe...

Страница 13: ...t put your Conference 1 on any unstable cart stand table etc And don t place the Conference 1 in damp areas or near places where water can collect For example don t place it near a pool tub wash basi...

Страница 14: ...vice see Section 3 4 7 NOTE These subsections frequently mention the RJ plugs on the cords attached to the Conference 1 s power supply One of these an RJ 11 plug is a 6 wire type RJ 12 as opposed to a...

Страница 15: ...1 s power supply has three cords attached to the transformer Take the one terminated with an RJ 11 plug and plug it into a standard telephone system wall jack 2 Plug the power supply s long base unit...

Страница 16: ...ER 3 Installation Figure 3 3 Attaching the Conference 1 to a standard phone line AC outlet Phone system wall jack AC input cord Base unit cord Conference 1 base unit Power supply s transformer Telepho...

Страница 17: ...r the symbols might be different consult the device s manual if you re not sure which jacks you should use 3 The Conference 1 s power supply has three cords attached to the transformer You won t use t...

Страница 18: ...ume Control Windows 95 2 Select MUTE for Line In Balance To select external signals with Microsoft Volume Control Recording 1 From the Volume Control menu select Options 2 Choose Properties from the O...

Страница 19: ...HONE Figure 3 5 The Volume Control window Volume Mute all Balance Volume Control Options Help Volume Control Volume Mute Balance Wave Volume Mute Balance Synth Volume Mute Balance CD Audio Volume Mute...

Страница 20: ...or DTE to the appropriate port on your computer usually one of its DB9 or DB25 serial ports 3 The Conference 1 s power supply has three cords attached to the transformer Take the one terminated with...

Страница 21: ...ng the Conference 1 to a modem to share its phone line AC outlet Phone system wall jack AC input cord Base unit cord Conference 1 base unit Power supply s transformer Telephone cord Telephone cable Mo...

Страница 22: ...e cords attached to the transformer Take the one terminated with an RJ 11 plug and plug it into one of the jacks on the line splitter 3 Plug the power supply s long base unit cord the one terminated w...

Страница 23: ...ttaching the Conference 1 to a two line phone service AC outlet Two line wall jack Line splitter AC input cord Base unit cord Conference 1 base unit Power supply s transformer Telephone cord Telephone...

Страница 24: ...ion switch to match the converter s impedance with that of the type of digital phone you re using Your converter s manual should tell you which setting to use 2 The Conference 1 s power supply has thr...

Страница 25: ...o a digital PBX phone system Digital PBX or multiline phone and handset Digital phone jack Conference 1 base unit Power supply s transformer Base unit cord Telephone cord Converter s power cord Digita...

Страница 26: ...f the unit REC OUT Plug the other end into the recording device s LINE IN jack NOTE Recording phone conversations without the knowledge and consent of all of the participants is illegal in many areas...

Страница 27: ...it s in with inaudible sound signals in order to determine the size and shape of the room for echo cancellation purposes If the Conference 1 later detects that it has been moved it will resample the r...

Страница 28: ...ontrolled menu etc Just switch to PULSE again before placing your next call 4 3 Placing a Standard Call To place a simple point to point phone call with the Conference 1 when it s connected to a stand...

Страница 29: ...E button during a call to turn the microphones off The status LEDs around the top of the Conference 1 will begin flashing about once a second To turn the microphones back on press MUTE again the statu...

Страница 30: ...one if you re adjusting the speakers or of a sample ring that the Conference 1 emits if you re adjusting the ringer will change by a discrete amount Also some of the status LEDs around the top of the...

Страница 31: ...ings to Check If Something Goes Wrong If you re having trouble with your Conference 1 it might not be set up properly or equipment connected to it might be improperly configured or malfunctioning Here...

Страница 32: ...they can If sound from the other location is muffled or echoes The other party might be in a very large room Ask them to either move closer to their phone s microphones or call from a smaller room If...

Страница 33: ...ny operating problem you haven t been able to solve make a record of the history of the problem We will be able to provide more efficient and accurate assistance if you have a complete description inc...

Страница 34: ...the possibility of such damages The laws of some areas don t allow the exclusion or limitation of incidental or consequential damages so those exclusions in this disclaimer might not apply to you TRA...

Страница 35: ...NOTES...

Страница 36: ...1000 Park Drive Lawrence PA 15055 1018 724 746 5500 Fax 724 746 0746 Copyright 2001 Black Box Corporation All rights reserved...

Отзывы: