877-877-2269   |   blackbox.com 

ACX1T

FCC and IC RFI Statements/WEEE/RoHS

Federal Communications Commission and Industry Canada Radio Frequency Interference 

Statements

This equipment generates, uses, and can radiate radio-frequency energy, and if not installed and used properly, that is, in strict 
accordance with the manufacturer’s instructions, may cause inter ference to radio communication. It has been tested and found to 
comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules, 
which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial 
environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own 
expense will be required to take whatever measures may be necessary to correct the interference.

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to  
operate the equipment.

This digital apparatus does not exceed the Class A limits for radio noise emis sion from digital apparatus set out in the Radio 
Interference Regulation of Industry Canada.

Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de 
la classe A prescrites dans le Règlement sur le brouillage radioélectrique publié par Industrie Canada.

WEEE

The manufacturer complies with the EC Directive 2002/96/EG on the prevention of waste electrical and electronic equipment 
(WEEE). The device labels carry a respective marking.

RoHS

This device complies with the EC Directive 2002/95/EG on the Restriction of the use of certain Hazardous Substances in electrical 
and electronic equipment (RoHS).

Содержание ACX1K

Страница 1: ...nd other peripheral devices Models available for CATx or fiber ServSwitch DKM Compact Extenders ACX1T Series ACX1R Series ACX1K Kits Order toll free in the U S or for FREE 24 7 Technical Support Call...

Страница 2: ...alk to Black Box You ll be live with one of our technical experts in less than 30 seconds Trademarks Used in this Manual Black Box and the Double Diamond logo are registered trademarks and ServSwitch...

Страница 3: ...t his own expense will be required to take whatever measures may be necessary to correct the interference Changes or modifications not expressly approved by the party responsible for compliance could...

Страница 4: ...idan el flujo de aire por los orificios de ventilaci n 10 El equipo el ctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u otros aparatos incluy...

Страница 5: ...th the product or manufacturer approved replacements Do not use a power supply if it appears to be defective or has a damaged case Connect all power supplies to grounded outlets In each case make sure...

Страница 6: ...eceiver Units CATx 20 2 3 2 DKM Compact Transmitter and Receiver Units Fiber 21 2 3 3 Upgrade Kits 21 2 3 4 Accessories 22 2 4 Device Views 22 2 4 1 ACX1T 11 C ACX1R 11 C Single Head CATx 22 2 4 2 ACX...

Страница 7: ...pplications 42 4 Configuration 44 4 1 Transmission Parameters 44 4 2 DDC Settings 44 4 3 Command Mode 44 5 Operation 46 6 Troubleshooting 47 6 1 Blank Screen 47 6 2 USB HID 48 6 3 Serial Connection 49...

Страница 8: ...th an integral USB hub such as Mac keyboards are also supported Mouse Compatible with most 2 button 3 button and scroll mice Other USB HID devices The proprietary USB emulation also supports certain o...

Страница 9: ...of several devices The serial interface transmits six signals three for each direction Normally four of the six signals are handshake signals in addition to RxD and TxD The following configurations ho...

Страница 10: ...16 bit 38 4 kHz Signal Level Line level 5 volt pk pk maximum Input Impedance 47 kOhm Connections CPU Unit 2 3 5 mm stereo audio plug audio in and audio out Connections CON Unit 2 3 5 mm stereo audio p...

Страница 11: ...g power cables If the site has 3 phase AC power make sure that CPU Unit and CON Unit are on the same phase CAUTION To maintain regulatory EMC compliance you must use correctly installed shielded CATx...

Страница 12: ...terconnect Cable Cable notations according to VDE Table 1 6 Fiber cable specifications Cable Type Description Single mode fiber 9 m Two 9 m fibers Indoor patch cable EFN310 xxM LCLC Multimode fiber 50...

Страница 13: ...USB hub 1 3 2 USB 2 0 Devices DKM Modular Extender models featuring a transparent USB 2 0 connection use Extreme USB Technology This technology supports all types of USB 2 0 devices however we cannot...

Страница 14: ...TMDS data 1 GND 19 TMDS data 0 GND 4 not connected 12 not connected 20 not connected 5 not connected 13 not connected 21 not connected 6 DDC input SCL 14 5 VDC high impedance 22 TMDS clock GND 7 DDC...

Страница 15: ...5 VDC Red 2 Data White 3 Data Green 4 GND Black Connector Mini USB Type B Figure 1 5 Mini USB Type B connector Table 1 12 Mini USB Type B connector pinout Pin Signal Color 1 VCC 5 VDC Red 2 Data White...

Страница 16: ...tor pinout Pin Signal 1 Data OUT 2 Data IN Power Supply Figure 1 8 Power supply label Table 1 15 Power supply connector pinout Pin Signal Inside VCC 5 VDC Outside GND DB9 Serial Figure 1 9 DB9 serial...

Страница 17: ...eo jack plug Table 1 17 3 5 mm stereo jack plug pinout Pin Signal 1 GND 2 Audio IN OUT L 3 Audio IN OUT R RCA Cinch Figure 1 11 RCA connector Table 1 18 RCA connector pinout Pin Signal 1 GND 2 Data IN...

Страница 18: ...80 non condensing 1 7 Size CPU Unit CON Unit SIngle head only devices Only ACX1T 11 xx and ACX1R 11 xx ACX1R 11V xxxx 4 H x 5 6 W x 1 1 D 10 3 x 14 3 x 2 9 cm Dual head devices and single head devices...

Страница 19: ...omagnetical aspects Electromagnetical interference can limit the maximum distance und reliability The DKM Compact Extender is fully compatible with the DKM Modular Extender The unit is designed to wor...

Страница 20: ...nit for DVI I VGA DVI single link up to 1920 x 1200 with 2 USB HID ports 4 USB 2 0 ports ACX1T 11V C Single head transmitter CPU unit for DVI I VGA DVI single link up to 1920 x 1200 with 2 USB HID por...

Страница 21: ...up to 1920 x 1200 with 4 USB HID ports unidirectional digital audio ACX1R12D SM Single head receiver console CON unit for single link up to 1920 x 1200 with 4 USB HID ports unidirectional digital aud...

Страница 22: ...3 5 mm stereo jack cable EJ514 0005 MM 5 foot 1 5 m RCA cable Cinch male connector EFJ04 001M 3 foot 1 m TOSLINK cable F05 male connector Contact Tech Support at 724 746 5500 or info blackbox com 6 fo...

Страница 23: ...CON unit Table 2 8 ACX1T 11 SM ACX1R 11 SM components CPU unit CON unit 1 Connect to 5 VDC power supply 1 Connect to 5 VDC power supply 2 Service port 2 Service port 3 Connect to interconnect cable 3...

Страница 24: ...CX1R 12A C components CPU unit CON unit 1 Connect to 5 VDC power supply 1 Connect to 5 VDC power supply 2 Service port 3 Service port 3 Connect to interconnect cable 3 Connect to interconnect cable 4...

Страница 25: ...CX1R 12A SM module components CPU unit CON unit 1 Connect to 5 VDC power supply 1 Connect to 5 VDC power supply 2 Service port 3 Service port 3 Connect to interconnect cable 3 Connect to interconnect...

Страница 26: ...12D C module components CPU unit CON unit 1 Connect to 5 VDC power supply 1 Connect to 5 VDC power supply 2 Service port 3 Service port 3 Connect to interconnect cable 3 Connect to interconnect cable...

Страница 27: ...R 12D SM module components CPU unit CON unit 1 Connect to 5 VDC power supply 1 Connect to 5 VDC power supply 2 Service port 3 Service port 3 Connect to interconnect cable 3 Connect to interconnect cab...

Страница 28: ...odule components CPU unit CON unit 1 Connect to 5 VDC power supply 1 Connect to 5 VDC power supply 2 Service port 1 3 Service port 1 3 Connect to interconnect cable 3 Connect to interconnect cable 4 T...

Страница 29: ...M module components CPU unit CON unit 1 Connect to 5 VDC power supply 1 Connect to 5 VDC power supply 2 Service port 1 3 Service port 1 3 Connect to interconnect cable 3 Connect to interconnect cable...

Страница 30: ...ect to 5 VDC power supply 2 Service port KVM 3 Service port 3 Connect to interconnect cable 3 Connect to interconnect cable 4 To CPU USB HID 4 Connect to USB HID devices 5 To CPU DVI I VGA DVI 5 Conne...

Страница 31: ...o 5 VDC power supply 2 Service port KVM 3 Service port 3 Connect to interconnect cable 3 Connect to interconnect cable 4 To CPU USB HID 4 Connect to USB HID devices 5 To CPU DVI I VGA DVI 5 Connect to...

Страница 32: ...ON unit 1 Connect to 5 VDC power supply 1 Connect to 5 VDC power supply 2 Service port 1 3 Service port 1 3 Connect to interconnect cable 3 Connect to interconnect cable 4 To CPU USB HID 1 4 Connect t...

Страница 33: ...CON unit 1 Connect to 5 VDC power supply 1 Connect to 5 VDC power supply 2 Service port 1 3 Service port 1 3 Connect to interconnect cable 3 Connect to interconnect cable 4 To CPU USB HID 1 4 Connect...

Страница 34: ...Description 1 Failure LED green Off Connection available On or Flashing Connection failure flashing for about 20 seconds following a connection failure 2 Status LED green Flashing No connection via in...

Страница 35: ...More information is available via on screen display OSD see the manual for the Media DVI Converter part number ACS411A R2 CPU unit CON unit Figure 2 17 Status digital audio option Table 2 23 LED 1 Dig...

Страница 36: ...LED 1 2 and 3 Status Position LED Status Description 1 2 Device LED orange Off No USB HID device or not supported USB device connected Flashing fast USB HID device active On USB HID device ready or D...

Страница 37: ...Ds 1 and 2 Status Position LED Status Description 1 Failure LED green Off Connection available On or flashing Connection failure flashing for about 20 seconds following a connection failure 2 Status L...

Страница 38: ...us Figure 2 20 VGA DVI I option front view multicolor LED Table 2 27 LED 1 Connection Status VGA DVI I Color Description Dark Red No video signal monitor not detected Red Video signal not supported mo...

Страница 39: ...untry specific power cords Quick Start Guide The Single Head devices also include 1 DVI video cable 6 ft 1 8 m DVI D male to male Figure 3 1 DVI video cable 1 USB cable 6 ft 1 8 m Type A to Type B Fig...

Страница 40: ...DVI D cable VGA cable 6 ft 1 8 m VGA male to DVI I male Figure 3 11 USB cable Infrared remote control 3 2 System Setup NOTE I f you are a first time user we recommend that you set up the system with...

Страница 41: ...You can hot plug the modules Analog Audio Serial Option 1 Connect the audio source with the CPU Unit for example CPU audio output with audio input CPU audio input with audio output 2 Connect the audio...

Страница 42: ...Installation 3 3 Example Applications This section illustrates typical installations of DKM Modular Extenders 1 2 3 4 5 Figure 3 12 DKM Modular Extender Single Head 1 2 3 4 5 Figure 3 13 DKM Modular...

Страница 43: ...through 3 14 Number Description 1 Source computer CPU 2 DKM Modular Extender CPU Unit 3 Interconnect cable 4 DKM Modular Extender CON Unit 5 Console keyboard monitor mouse 6 Second monitor option only...

Страница 44: ...Unit or CON Unit The current DDC information is replaced Retrieving DDC Information Copy the file DDC EDID bin on the flash drive of the CPU Unit to your computer To open the binary file you have to...

Страница 45: ...keys successively 2x Key Press key quickly twice in a row similar to a mouse click You can change the hotkey sequence to enter Command Mode Table 4 3 lists the hotkey codes for the available key sequ...

Страница 46: ...nder operating conditions 1 Enter Command Mode with the hotkey see Section 4 2 2 Press the a key to download the DDC information of the console monitor The screen goes black for a short time At the sa...

Страница 47: ...t Check interconnect cables and connections CPU unit LED 3 red or yellow No video signal detected by source computer CPU Check DVI D cable to CPU Download DDC information from console monitors see Cha...

Страница 48: ...nnection to CPU Check connection of USB cable to CPU select another USB port if necessary Remove USB and power cable and restart CPU Connect power cable first CON unit LED 3 green or violet Problems w...

Страница 49: ...Audio Table 6 4 Analog audio troubleshooting Diagnosis Possible Reason Measure CON unit No signal at audio output No audio connection to CPU audio source Connect analog audio source Check audio cable...

Страница 50: ...ection to CPU audio source Connect digital audio source Check connection of audio cable No signal Switch digital audio source on Activate digital output at CPU audio source CON unit LED 1 red No audio...

Страница 51: ...connection of USB cable to USB HID device Connect USB HID device Contact Black Box Technical Support at 724 746 5500 or info blackbox com if necessary CPU unit LED 3 off Connection between CON unit an...

Страница 52: ...ort if necessary Remove USB and power cable and restart CPU Connect power cable first CON unit LED 3 red Connection between CON unit and CPU unit Check interconnect cable and connectors CON unit LED 3...

Страница 53: ...ide more efficient and accurate assistance if you have a complete description including the nature and duration of the problem when the problem occurs the components involved in the problem any partic...

Страница 54: ...ignals up to 330 MPixel s 24 bit DVI Digital video standard introduced by the Digital Display Working Group http www ddwg org Single Link and Dual Link standard are distinguished The signals have TMDS...

Страница 55: ...connection Triple Head A system with three video connections USB HID USB HID devices Human Interface Device allow for data input There is no need for a special driver during installation New USB HID d...