Operation

General use

In use, the SRX modules should be transparent - the system and its peripherals 
should operate exactly as normal, the only difference being that they are now up 
to 50 metres apart. 
In some installations, you may see some ‘shadows’ to the right of high contrast 
screen characters. This can be caused by an incorrectly selected sharpness setting 
and it may be necessary to make adjustments to correct this. Please see 

Video.

sharpness.adjustment

 in the ‘Installation’ section.

Dual user arbitration

When using two sets of SRX modules to allow two users to access a single 
computer, be aware that arbitration between the users is handled by the USB 
sub-system of the computer. Unlike with other Black Box products, this means 
that both users can control the computer at exactly the same time and the 
resulting keyboard and mouse influences will be an amalgam of the two inputs 
- i.e. a mouse move to the right by one user will cancel out a simultaneous left 
mouse move by the other. The same is also true when the local module has 
feed-through peripherals attached to it, adjacent to the computer. 
For this reason, the SRX dual user arrangement is better suited to situations 
where two users would not often require simultaneous access.

Peripheral operation

USB

Each SRX remote module provides four USB outlets, each of which can support 
USB 2.0 peripherals at speeds up to 12Mbps. The SRX appears to the computer 
as a four-port USB hub.
If the link between the modules is interrupted, any connected USB peripherals 
will be automatically disabled and re-enabled once the connection is restored.

[MS2 variant only] Note: When connecting four USB devices to the unit, ensure 
that their total power requirements do not exceed 1700mA (1.7A). The USB 
standard states a maximum allowable current draw of 500mA (0.5A) per device, 
although most devices remain well below this limit - USB keyboards and mice 
typically require 100mA. Each X50 contains a self-resetting fuse that will prevent 
damage by shutting down the unit if the total power draw becomes excessive.

 

RS232 serial

The dual VGA variant modules provide additional support for an RS232 device. 
The 9 way male D-type socket on the remote module supports speeds up to 
115,200 baud and all PC-AT flow control pins are supported.  

Содержание ACU5051A

Страница 1: ...DE NETWORK SERVICES Order toll free in the U S Call 877 877 BBOX outside U S call 724 746 5500 FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing address...

Страница 2: ...at the remote module 8 Dual user configuration 10 Video display DDC information 11 Video sharpness adjustment 12 Operation General use 13 Dual user arbitration 13 Peripheral operation 13 Further info...

Страница 3: ...est interludes The USB connections are seamless and thanks to our unique Bi tripos circuitry four full speed USB 2 0 devices can be used simultaneously with full support for disconnect re connect at a...

Страница 4: ...module BL AC K BO X SRX TO LO CAL LINK PO W ER SH ARP NES S B A A B ON REMOTE 724 746 5500 SRX Dual VGA remote module USB A to B type lead Audio lead 3 5mm jacks Video lead 15 way male to male RS232...

Страница 5: ...welcome contents installation operation Optional items Power adapter and country specific power lead for local module if USB powering not possible Rack mount chassis...

Страница 6: ...lug the SRX local module into another USB hub To do so will reduce the maximum cable length over which the system will extend USB also some USB hubs may not provide enough power to operate the local u...

Страница 7: ...h the video USB see the Important note on page 5 and optionally audio connections from the computer system to the relevant sockets on the local module Dual VGA variant only Optionally attach a second...

Страница 8: ...ule and attach the other end to a vacant serial port on your computer 5 Attach the connector of the category 5 5e or 6 link cable up to 50 metres in length to the TO REMOTE socket on the local module...

Страница 9: ...Dual VGA variant only Optionally attach the lead from a second video monitor to the upper video out socket on the remote module To secondary video monitor BLACK BOX REMOTE A B REMOTE To USB devices e...

Страница 10: ...H A R P N E S S O N 5 5 0 0 S R X T O L O C A L L IN K P O W E R S H A R P N E S S B A O N Dual VGA variant only Attach the connector of a second category 5 5e or 6 link cable up to 50 metres in lengt...

Страница 11: ...IDEO USB USER 1 USER 2 BLACK BOX SRX TO REMOTE LINK POWER ON LOCAL 724 746 5500 IN OUT IN OUT BLACK BOX SRX TO REMOTE LINK POWER ON LOCAL 724 746 5500 IN OUT IN OUT BLACK BOX SRX TO LOCAL LINK POWER S...

Страница 12: ...local module is powered up it will read and store the DDC information from your monitor You can then return the monitor to its remote position and the new DDC information will be used at every power...

Страница 13: ...ntrast image The best way to clearly view the effect of sharpness and brightness adjustments is to display a high contrast image with vertical edges on the screen Open a word processor type the capita...

Страница 14: ...en the local module has feed through peripherals attached to it adjacent to the computer For this reason the SRX dual user arrangement is better suited to situations where two users would not often re...

Страница 15: ...cksum error prior to copying no information will be programmed Three yellow flashes Too much data to fit into the module the module can hold a maximum of two pages of DDC information Rapid yellow flas...

Страница 16: ...e power adapter into a socket outlet close to the module that it is powering Replace the power adapter with a manufacturer approved type only Do not use the power adapter if the power adapter case bec...

Страница 17: ...ease the separation between the equipment and the receiver c Connect the equipment to an outlet on a circuit different from that to which the receiver is connected d Consult the supplier or an experie...

Страница 18: ...que impidan el flujo de aire por los orificios de ventilaci n 10 El equipo el ctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u otros aparatos...

Страница 19: ...n further information 18 www ctxd com Documentation by 2009 Black Box Corporation All trademarks are acknowledged Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 United States of America...

Страница 20: ...x fr 33 1 45 606 717 33 1 45 606 747 tech blackbox fr Germany www black box de 49 811 5541 110 49 811 5541 499 techsupp black box de Italy www blackbox it 39 02 27 404 700 39 02 27 400 219 supporto te...

Отзывы: