RESTORING A BACKUP FIRMWARE IMAGE
The Agility Zero U unit retains a backup image of the previous firmware version in order to provide a fallback in case of any issues
with the primary image. The backup image has no video or USB functionality; once invoked, you will need to load an upgrade file
using the web interface or via an iPATH Agility Controller to load a new primary image - see Performing an upgrade (shown right).
TO RESTORE THE BACKUP FIRMWARE IMAGE
1 Power on the Agility Zero U unit.
2 Use a narrow implement (e.g. a straightened-out paper clip) to press-and-hold the recessed reset button for roughly ten
seconds until the indicators flash
green
/
red
.
3 Release the reset switch.
The Agility Zero U unit will switch to the backup firmware image. Once complete, Agility Zero U unit will then continually flash
green
/
red
.
4 Perform an upgrade to reinstate a fresh primary firmware image - see next page.