background image

 

 

4.9 IGMP Snooping 

The function, IGMP Snooping, is used to establish the multicast groups to forward the multicast packet to the 
member ports, and, in nature, avoids wasting the bandwidth while IP multicast packets are running over the 
network. This is because a switch that does not support IGMP or IGMP Snooping can not tell the multicast 
packet from the broadcast packet, so it can only treat them all as the broadcast packet. Without IGMP 
Snooping, the multicast packet forwarding function is plain and nothing is different from broadcast packet. 

A switch supported IGMP Snooping with the functions of query, report and leave, a type of packet exchanged 
between IP Multicast Router/Switch and IP Multicast Host, can update the information of the Multicast table 
when a member (port) joins or leaves an IP Multicast Destination Address. With this function, once a switch 
receives an IP multicast packet, it will forward the packet to the members who joined in a specified IP multicast 
group before. 

The packets will be discarded by the IGMP Snooping if the user transmits multicast packets to the multicast 
group that had not been built up in advance. 

Table 4-24. IGMP Snooping screen options. 

Parameter Description 

IGMP Snooping 

IGMP is used to snoop the status of IP multicast groups and 
display its associated information in both tagged VLAN and 
non-tagged VLAN networks.    Enabling IGMP with either passive 
or active mode, you can monitor the IGMP snooping information, 
which contains the multicast member list with the multicast groups, 
VID and member port.   

IGMP snooping mode selection 

The switch supports three kinds of IGMP Snooping status, 
including “Passive”, “Active” and “Disable”. 

Disable: 

Set “Disable” mode to disable IGMP Snooping function.   
Default: Disable 

Active: 

In Active mode, IGMP snooping switch will periodically issue the 
Membership Query message to all hosts attached to it and gather 
the Membership report message to update the database of the 
Multicast table. By the way, this also reduces the unnecessary 
multicast traffic. 

Passive:  

In Passive Snooping mode, the IGMP snooping will not periodically 
poll the hosts in the groups. The switch will send a Membership 
Query message to all hosts only when it has received a 
Membership Query message from a router. 

 

 

 

 

CHAPTER 4: Web-Based Management     

57 

Содержание 12-Port 1000BASE-TX L2 Managed PoE Switch

Страница 1: ...Copyright 2006 Black Box Corporation All rights reserved...

Страница 2: ...24 hours a day 7 days a week Call or fax Mailing address 1000 Park Drive Lawrence PA15055 1018 Web site E mail toll free 877 877 BBOX 724 746 5500 FREE 724 746 5500 724 746 0746 Black Box Corporation...

Страница 3: ......

Страница 4: ...ved by the party responsible for compliance could void the user s authority to operate the equipment This digital apparatus does not exceed the Class A limits for radio noise emission from digital app...

Страница 5: ...uipo el ctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufasu otros aparatos incluyendo amplificadores que producen calor 11 El aparato el ctrico d...

Страница 6: ...NT are registered trademarks of Microsoft Corporation Netscape is a registered trademark of Netscape Communications Corporation Telnet is a trademark of Telnet Communications Inc UNIX is a registered...

Страница 7: ...the Management Agent 21 3 4 1 Via the Serial RS 232 Console Port 22 3 4 2 Via the Ethernet Port 24 3 5 IP Address Assignment 25 3 5 1 IP Address 25 3 5 2 Subnet Mask 26 3 5 3 Default Gateway 27 3 5 4...

Страница 8: ...0 Max Packet Length 58 4 11 DHCP Boot 58 4 12 VLAN 58 4 12 1 VLAN Mode 59 4 12 2 Tag Based Group 60 4 12 3 Port Based Group 60 4 12 4 Tag Rule 61 4 13 MAC Table 62 4 13 1 MAC Table Information 62 4 13...

Страница 9: ...ore 85 4 19 2 Config File 85 4 20 Diagnostics 86 4 20 1 Diag 86 4 20 2 Loopback Test 86 4 20 3 Ping Test 86 4 21 TFTP Server 87 4 22 Log 87 4 23 Firmware Upgrade 87 4 24 Reboot 88 4 25 Logout 89 5 CLI...

Страница 10: ...ng Filtering Packet Rate 1 488 000 pps at 1000 Mbps 148 800 pps at 100 Mbps 14 880 pps at 10 Mbps MAC Address and Self Learning 8K MAC address 4K VLAN table entries Buffer Memory Embedded frame buffer...

Страница 11: ...dth Control Supports by port Egress Ingress rate control Quality of Service QoS Referred to as Class of Service CoS by the IEEE802 1p standard classification of packet priority can be based on either...

Страница 12: ...DB9 connector pin out Function Pin Carrier CD 1 Receive Data RXD 2 Transmit Data TXD 3 Data Terminal Ready DTR 4 Signal Ground GND 5 Data Set Ready DSR 6 Request To Send RTS 7 Clear To Send CTS 8 Tab...

Страница 13: ...st Storm Control IEEE 802 1q in q nested VLAN support full duplex flow control IEEE 802 3x and half duplex backpressure and extensive front panel diagnostic LEDs Software features include port status...

Страница 14: ...ion for Remote Network Monitoring and is a branch of the SNMP MIB The device supports MIB 2 RFC 1213 Bridge MIB RFC 1493 RMON MIB RFC 1757 statistics Group1 2 3 and 9 Ethernet like MIB RFC 1643 and Et...

Страница 15: ...hen PoE Power is failed g 10 100 1000Mbps LEDs ports 1 12 Lights green when 1000Mbps speed is active Lights ember when 100Mbps speed is active Off when 10Mbps speed is active h LINK ACT LEDs ports 1 1...

Страница 16: ...FP fiber port module slots The switch s rear panel is shown in Figure 2 2 The numbered components in the figure are described in Table 2 2 Figure 2 2 Rear panel Table 2 2 Rear panel components Compone...

Страница 17: ...eiver modules are available These modules are described below and shown in Figures 2 3 and 2 4 Small Form Factor Pluggable SFP Optical Transceiver Multimode 850 nm 550 m LGB200C MLC Small Form Factor...

Страница 18: ...1 Installing the optional SFP fiber transceiver module Connecting the SFP Module to the Chassis The optional SFP modules are hot swappable so you can plug or unplug them before or after powering on t...

Страница 19: ...a workstation or server or fiber transceiver module is plugged into the switch or not when powered on After the power is on all LED indicators will light up immediately and then all LEDs except the p...

Страница 20: ...single strand single mode Gigabit fiber with BiDi LC1550 nm SFP module LGB205C 3 3 3 SWITCH CASCADING Theoretically the switch partitions the collision domain for each port in switch cascading so that...

Страница 21: ...Topology in Deployment A hierarchical network with minimum switch levels may reduce the timing delay between the server and the client station This approach will minimize the number of switches in any...

Страница 22: ...ation Figures 3 4 and 3 5 show a port based VLAN and Figure 3 6 shows an attribute based VLAN 12 Port 1000BASE TX L2 Managed PoE Switch with 2 SFP Dual Media Ports VLAN 1 VLAN 2 VLAN 3 VLAN 4 Figure 3...

Страница 23: ...access VLAN 1 and VLAN 3 members but they can access VLAN 4 members VLAN 3 members can t access VLAN 1 VLAN 2 and VLAN 4 VLAN 4 members can t access VLAN 1 and VLAN 3 members but they can access VLAN...

Страница 24: ...switch management function RS 232 console and Ethernet port Use one to monitor and configure the switch Follow the instructions in Sections 3 4 1 and 3 4 2 NOTE Modify the IP address subnet mask defau...

Страница 25: ...rial RS 232 DB9 connector 2 Attach the other end of the serial RS 232 DB9 cable to the PC s serial port running a terminal emulator supporting a VT100 ANSI terminal with the switch s serial port defau...

Страница 26: ...ch s IP address then change the default gateway s IP address and subnet mask For example suppose your network address is 10 1 1 0 and the subnet mask is 255 255 255 0 You can change the switch s defau...

Страница 27: ...steps listed below 1 Connect the switch and PC together via UTP CAT5 cable with RJ 45 connectors NOTE If the PC directly connects to the switch set up the same subnet mask between them If the PC conn...

Страница 28: ...is less than 126 255 255 255 A total of 126 networks can be defined The address 0 0 0 0 is reserved for default route and 127 0 0 0 8 is reserved for loop back function Class B The IP address ranges...

Страница 29: ...with all zeros and all ones host number As shown in the table below the subnet mask with a 25 bit long 255 255 255 128 address contains 126 members in the subnetted network The network prefix length...

Страница 30: ...55 255 255 x is allowed 3 5 4 DNS The Domain Name Server translates a human readable machine name to an IP address Every machine on the Internet has a unique IP address A server generally has a static...

Страница 31: ...FTTB FTTO CONNECTION Figure 3 10 shows a FTTB FTTO application is used in carrier or ISP Figure 3 10 Network Connection of FTTB FTTO 12 Port 1000BASE TX L2 Managed PoE Switch with 2 SFP Dual Media Por...

Страница 32: ...3 6 2 FTTH CONNECTION Figure 3 11 shows a FTTH application is used in carrier or ISP Figure 3 11 Network Connection of FTTH CHAPTER 3 Installation 29...

Страница 33: ...IN FIBER NETWORK CONNECTION Figure 3 12 shows the Daisy Chain Fiber Network Connection Figure 3 12 Typical office network using three switches 12 Port 1000BASE TX L2 Managed PoE Switch with 2 SFP Dual...

Страница 34: ...a network port you must first configure the switch in its command line interface CLI from the connected a sync serial COM RS 232 interface For details see Chapter 5 Once you configure the switch type...

Страница 35: ...f the screen the switch s front panel diagram appears The linked ports display green and the unlinked ports appear dark The slot shows only a cover plate if no module exists and it shows a module if a...

Страница 36: ...tem time Its format is day of week month day hours minutes seconds year For example Wed Apr 26 12 10 10 2006 BIOS Version The switch s BIOS version Firmware Version The switch s firmware version Hardw...

Страница 37: ...h will issue the request and show the IP address as requesting until the DHCP server is up Before getting an IP address from the DHCP server the device will not continue booting procedures If this fie...

Страница 38: ...e address into an IP address There are two ways to specify the DNSIP address Fixed mode manually specifies its IP address and dynamic mode is assigned by the DHCP server while DHCP is enabled DNS can...

Страница 39: ...user defined NTP server as well as Time Zone the switch will sync the time after you press the Apply button Though it synchronizes the time automatically NTP does not update the time periodically with...

Страница 40: ...lick on this button to apply the settings 4 2 4 ACCOUNT CONFIGURATION To get to the Account Configuration screen click on Account in the System menu Only the user logged in as administrator can create...

Страница 41: ...tions excluding the connection inside the accepting range 5 When both accept and deny lists exist then the switch will deny all connections excluding the connection inside the accepting range and NOT...

Страница 42: ...ustom button you can check the box next to the option you want to use to access and manage the switch The three options include HTTP Telnet and SNMP Action The switch supports two options for managed...

Страница 43: ...the Master device with the smaller MAC value will be the Master one All 16 devices can become a Master device and back up each other Table 4 8 Virtual Stack screen options Parameter Description State...

Страница 44: ...k Shows if the link on the port is active or not If the link is connected to a device that is working properly the Link will show the link Up otherwise it will show Down Both connected devices determi...

Страница 45: ...of them Default Disable Wait State For 10 100M ports there is no side effect on this setting For Gigabit ports setting of Wait State will remove the issue with ignored pause frames but resolve in the...

Страница 46: ...n3 RX PWR Shows the SFP module s receiver power Close button Click on this button to close the window 4 3 2 CONFIGURATION Use the Configuration menu to change each port s setting To get to this screen...

Страница 47: ...ransmitting device s if the receiving port is too busy to handle When it is set Asymmetric this will let the receiving port care the PAUSE frame from transmitting device s but it doesn t send PAUSE fr...

Страница 48: ...received 4 3 4 DETAIL COUNTER The Detail Counter collects any information and provides the port traffic counting whether the packet is good or bad To get to this screen click on Detail Counter in the...

Страница 49: ...y Rx Low Priority Packets Number of Rx packets classified as low priority Rx Broadcast Packets Show the counting number of the received broadcast packets Rx Multicast Packets Show the counting number...

Страница 50: ...n good and bad packets transmitted Tx 512 1023 Bytes Number of 512 1023 byte frames in good and bad packets transmitted Tx 1024 Bytes Number of 1024 max_length byte frames in good and bad packets tran...

Страница 51: ...t Port Off Port is turned off due to the DC Disconnect function Overload Port Off The switch will stop supplying the power to the port due to the power required by the PD that is linked to the port on...

Страница 52: ...egal while the port linked to the PD Disable means the port does not own PoE function Priority Three options are offered for the user to choose including Normal Low and High Default is Normal The swit...

Страница 53: ...ction to work on it Valid range of the port is 1 12 All Traffic for Ingress Rate Limiting Policing Set up the limit of Ingress bandwidth for the port you choose Incoming traffic will be discarded if t...

Страница 54: ...ens because Port 2 owns higher precedence of transmitting packets Table 4 18 Per Port Priority screen options Parameter Description Port No User can choose the port 1 12 respectively with Priority Cla...

Страница 55: ...we will create the 8 traffic packets we meant before Moreover we can set High priority or Low priority for each traffic class For instance if we let TOS 0 0 0 be high priority and TOS 0 0 1 be Low Pr...

Страница 56: ...button to have this function taken affect Then click Advance button to set up Special TCP UDP port for QoS Down prioritize web browsing e mail FTP and news Belong to the QoS in L4 Just tick the option...

Страница 57: ...other TCP UDP ports There are two modes for selection including Low and High Port User can set up the port 1 12 respectively to let Special TDP UDP class function work on them If you would like to set...

Страница 58: ...ided that the Management Information Base MIB is installed correctly on the managed devices The SNMP is a protocol that is used to govern the transfer of information between SNMP manager and agent and...

Страница 59: ...lt community name for GET public Default community name for SET private Default community name for Trap public Default Set function Enable Default trap host IP address 0 0 0 0 Default port number 162...

Страница 60: ...the user transmits multicast packets to the multicast group that had not been built up in advance Table 4 24 IGMP Snooping screen options Parameter Description IGMP Snooping IGMP is used to snoop the...

Страница 61: ...rver and many connections predefined when the whole building or block lose the power and then reboot and recover At this moment a bunch of switch or other network device on the LAN will try its best t...

Страница 62: ...ist the packet will be screened with more filtering criteria to determine if it can be forwarded The switch supports supplement of 802 1q Each tag based VLAN you built up must be assigned VLAN name an...

Страница 63: ...oup Member This is used to enable or disable if a port is a member of the new added VLAN Enable means it is a member of the VLAN Just tick the check box beside the port x to enable it Add Group Create...

Страница 64: ...two ingress filtering rules which can be applied to the switch The Ingress Filtering Rule 1 is forward only packets with VID matching this port s configured VID The Ingress Filtering Rule 2 is drop u...

Страница 65: ...carry no VLAN tag header If packets have double VLAN tags one will be dropped and the other will still be left As to Hybrid it is similar to Trunk and both of them will tag out When the port is set t...

Страница 66: ...this MAC Entry is built It may show Dynamic MAC or Static MAC 4 13 2 MAC TABLE MAINTENANCE This function can allow the user to set up the processing mechanism of MAC Table An idle MAC address exceedin...

Страница 67: ...hex and separated by hyphens For example 00 40 C7 D6 00 00 Port No Port number of the switch It is 1 12 VID VLAN identifier This will be filled only when tagged VLAN is applied Valid range is 1 4094...

Страница 68: ...is a six byte long Ethernet hardware address and usually expressed by hex and separated by hyphens For example 00 40 C7 D6 00 01 Alias MAC alias name you assign NOTE If there are too many MAC addresse...

Страница 69: ...ve Time in unit of centisecond Valid time range 60 300 centisecond Default 60 centisecond Leave All Time A time period for announcement that all registered device is going to be de registered If someo...

Страница 70: ...re two modes disable and enable provided for the user s choice Disabled In this mode the switch dynamic VLAN will be created when this port received GVRP PDU The default setting is Normal Enabled In t...

Страница 71: ...VLAN identifier When GVRP group creates each dynamic VLAN group owns its VID Valid range is 1 4094 Member Port Those are the members belonging to the same dynamic VLAN group Edit Administrative Contr...

Страница 72: ...current root bridge maximum age time Maximum age time is used to monitor if STP topology needs to change When a bridge does not receive a hello message from root bridge until the maximum age time is c...

Страница 73: ...4 37 STP Configuration screen options Parameter Description STP Configuration User can set the following Spanning Tree parameters to control STP function enable disable select mode RSTP STP and affec...

Страница 74: ...rwarding state of a port in bridge The forward delay time contains two states Listening state to Learning state and Learning state to Forwarding state It assumes that forward delay time is 15 seconds...

Страница 75: ...to Root Bridge STP algorithm determines a best path to Root Bridge by calculating the sum of path cost contributed by all ports on this path A port with a smaller path cost value would become the Roo...

Страница 76: ...a trunk group without any handshaking with its peer port This is also a disadvantage because the peer ports of your static trunk group may not know that they should be aggregate together to form a lo...

Страница 77: ...ferenced when a port s trunking method is LACP Active An Active LACP port begins to send LACPDU to its link partner right after the LACP protocol entity started to take control of this port Passive A...

Страница 78: ...ly the ready member ports within an aggregator port This page shows the detailed information of the LACP trunking group Table 4 41 LACP Detail screen options Parameter Description Actor The switch you...

Страница 79: ...ning authorization before sending or receiving any packets from a 802 1x enabled port Before the devices or end stations can access the network resources through the ports under 802 1x control the dev...

Страница 80: ...ssfully authenticating the supplicant can only touch the authenticator to perform authentication message exchange or access the network from the uncontrolled port Figure 4 1 In the Fig 4 2 this is the...

Страница 81: ...ity to the authenticator The authenticator will embed the user ID into Radius Access Request command and send it to the authentication server for confirming its identity 6 After receiving the Radius A...

Страница 82: ...cation supported in the switch In this mode for the devices connected to this port once a supplicant is authorized the devices connected to this port can access the network resource through this port...

Страница 83: ...l parameters for RADIUS authentication in 802 1x port security application Radius Server RADIUS server IP address for authentication Default 192 168 1 1 Port Number The port number to communicate with...

Страница 84: ...status authorized or unauthorized Table 4 46 Port Security Management screen options Parameter Description Disable Mode When selecting Disable mode for a port in the function 802 1X Port Mode Configur...

Страница 85: ...horized state ForceAuthorized The controlled port is forced to hold in the authorized state Auto The controlled port is set to be in authorized state or unauthorized state depends on the result of the...

Страница 86: ...tion is used to enable the switch to send out the trap information while pre defined trap events occurred The switch offers 22 different trap events to users for switch management The trap information...

Страница 87: ...like to receive the alarm message SMS SMS Server the IP address of the server transferring your SMS Username your username in ISP Password your username in ISP Mobile Phone 1 6 the mobile phone numbe...

Страница 88: ...store Default Configuration function can retrieve the manufacturer s setting to replace the start configuration However the switch s current IP address that the user set up will not be changed and wil...

Страница 89: ...nd in the switch box As to the latter test function it will send the test signal to its link partner If you do not have them connected to active network devices i e the ports are link down the switch...

Страница 90: ...the report table No Time and Events are three fields contained in each trap record No Display the order number that the trap happened Time Display the time that the trap happened Events Display the t...

Страница 91: ...t to upgrade 4 24 Reboot We offer you many ways to reboot the switch including power up hardware reset and software reset You can press the RESET button in the front panel to reset the switch After up...

Страница 92: ...ut and exit the browser the switch will automatically have you logout Besides this manually logout and implicit logout you can pull down the Auto Logout list at the left top corner to explicitly ON OF...

Страница 93: ...ise it appears as The former means you act as an administrator and have all system access rights The latter means you act as a guest and are only allowed to view the system without permission to apply...

Страница 94: ...B200A 802 1x Enter into 802 1x mode account Enter into account mode alarm Enter into alarm mode autologout Change autologout time bandwidth Enter into bandwidth mode config file Enter into config file...

Страница 95: ...more than two words When you enter this command the CLI shows the complete commands This command also helps you classify the commands as either local or global commands Argument None Possible value No...

Страница 96: ...re run When you enter this command the CLI shows a list of commands that you typed previously The CLI supports up to 256 records If you don t type in anything the CLI lists up to 256 total records If...

Страница 97: ...restore the default IP address y n If you choose Y or y the IP address will restore to the default 192 168 1 1 If you choose N or n the IP address will keep the same one that you saved before If rest...

Страница 98: ...estoring Restore User Configuration Successfully Press any key to reboot system save start Syntax save start Description Saves the current configuration as the startup one When you enter this command...

Страница 99: ...achine will retransmit an EAP Request packet to the Supplicant before it times out the authentication session Argument port range syntax 1 5 7 available from 1 to 12 times max times range 1 10 Possibl...

Страница 100: ...1 to 12 authorized 0 1 or 2 Example Giga Switch 802 1X set port control 2 2 set quiet period Syntax set quiet period port range sec Description A timer that the Authenticator state machine uses to def...

Страница 101: ...Possible value port range 1 to 12 ebl 0 or 1 default is 1 Example Giga Switch 802 1X set reAuthEnabled 2 1 set reAuthMax Syntax set reAuthMax port range max Description The number of reauthentication...

Страница 102: ...the backend authentication state machine determines timeout conditions in the exchanges between the Authenticator and the Supplicant or Authentication Server A state machine is a service within the sw...

Страница 103: ...timer used by the Backend Authentication state machine that determines timeout conditions in the exchanges between the Authenticator and the Supplicant or Authentication Server A state machine is a se...

Страница 104: ...vailable from 1 to 12 sec timer range 1 65535 Possible value port range 1 to 12 sec 1 65535 default is 30 Example Giga Switch 802 1X set txPeriod 2 30 show mode Syntax show mode Description Displays e...

Страница 105: ...60 reAuthEnabled ON reAuthPeriod 3600 max Request 2 suppTimeout 30 serverTimeout 30 port 2 port control Auto reAuthMax 2 txPeriod 30 Quiet Period 60 reAuthEnabled ON reAuthPeriod 3600 max Request 2 su...

Страница 106: ...s server s configuration Argument None Possible value None Example Giga Switch 802 1X show state Radius Server 192 168 1 115 Port Number 1812 Secret Key WinRadius account add Syntax add name Descripti...

Страница 107: ...aaaa Account aaaaa deleted Modify Syntax modify name Description Changes an existing account s username and password Argument name existing user account Possible value None Example Giga Switch account...

Страница 108: ...ail address Syntax del mail address Description Removes the email address configuration Argument email address number range of 1 to 6 Possible value 1 to 6 Example Giga Switch alarm email del mail add...

Страница 109: ...t server ip Description Sets up the email server s IP address Argument ip email server ip address or domain name Possible value None Example Giga Switch alarm email set server 192 168 1 6 set user Syn...

Страница 110: ...e admin Password Email Address 1 abc mail abc com Email Address 2 Email Address 3 Email Address 4 Email Address 5 Email Address 6 events del all Syntax del all range Description Disables email sms and...

Страница 111: ...e Description Disables the events sms Argument range del the range of sms syntax 1 5 7 Possible value range 1 26 Example Giga Switch alarm events del sms 1 3 del trap Syntax del trap range Description...

Страница 112: ...email Argument range set the range of email syntax 1 5 7 Possible value range 1 26 Example Giga Switch alarm events set email 1 3 set sms Syntax set sms range Description Enables the events sms Argum...

Страница 113: ...Link Up v 5 Authentication Failure v 6 User Login 7 User Logout 8 STP Topology Changed 9 STP Disabled 10 STP Enabled 11 LACP Disabled 12 LACP Enabled 13 LACP Member Added 14 LACP Port Failure 15 GVRP...

Страница 114: ...sms del phone number Syntax del phone number Description Deletes the sms phone number Argument mobile phone number range of 1 to 6 Possible value 1 to 6 Example Giga Switch alarm sms del phone number...

Страница 115: ...x set server ip Description Sets up the sms server s IP address Argument ip SMS server ip address or domain name Possible value None Example Giga Switch alarm sms set server 192 168 1 7 set user Synta...

Страница 116: ...ne 1 0968777777 Mobile Phone 2 Mobile Phone 3 Mobile Phone 4 Mobile Phone 5 Mobile Phone 6 autologout autologout Syntax autologout time Description Sets up the autologout timer Argument time range 1 t...

Страница 117: ...e range Description Cancels the port s Ingress rate Argument range syntax 1 5 7 available from 1 to 12 Possible value range 1 to 12 Example Giga Switch bandwidth disable ingress rate 1 8 disable storm...

Страница 118: ...width enable egress rate 1 8 200 enable ingress rate Syntax enable ingress rate range data_rate Description Sets up the port s Ingress rate Argument range syntax 1 5 7 available from 1 to 12 data_rate...

Страница 119: ...e Example Giga Switch bandwidth show Ingress Egress Port All State All Rate Storm State Storm Rate All state All Rate 1 Disabled 0 Disabled 0 Disabled 0 2 Disabled 0 Disabled 0 Disabled 0 3 Disabled 0...

Страница 120: ...ort user conf Syntax export user conf Description Runs the export user conf function Argument None Possible value None Example Giga Switch config file export user conf Export successful import start S...

Страница 121: ...exported Argument filepath filepath and filename Possible value filepath filepath and filename Example Giga Switch config file set export path log 21511 txt set import path Syntax set import path fil...

Страница 122: ...lename user123 txt dhcp boot set dhcp boot Syntax set dhcp boot sec Description Sets up the DHCPBoot delay time Argument sec range syntax 0 1 30 0 disables dhcp boot delay Possible value sec 0 30 Exam...

Страница 123: ...rnal External Loopback Test Argument None Possible value None Example Giga Switch diag loopback Internal Loopback Test OK External Loopback Test Port 1 2 3 4 5 6 7 8 Fail ping Syntax ping ip Descripti...

Страница 124: ...epath upgrade file path Example Giga Switch firmware set upgrade path gs2108c_Giga Switch_v2 03 img show Syntax show Description Displays the tftp server and upgrade path information Argument None Pos...

Страница 125: ...sible value None Example Giga Switch gvrp enable group Syntax group group number Description Enter any gvrp group for which you want to change the gvrp group setting You can change the applicant or re...

Страница 126: ...rmal Normal 8 Normal Normal Giga Switch gvrp group 2 set registrar 1 8 fixed Giga Switch gvrp group 2 show GVRP group VID 2 Port Applicant Registrar 1 Non Participant Fixed 2 Non Participant Fixed 3 N...

Страница 127: ...et registrar as fixed mode forbidden set registrar as forbidden mode Possible value range 1 to 12 normal fixed forbidden normal fixed or forbidden Example Giga Switch gvrp set registrar 1 5 fixed set...

Страница 128: ...l Enable set timer Syntax set timer range join leave leaveall Description Sets each port s gvrp join time leave time and leave all time Argument range port range syntax 1 5 7 available from 1 to 12 jo...

Страница 129: ...able 8 25 80 2000 Normal Normal Disable show counter Syntax show counter port Description Displays the port s counter number Argument port port number Possible value port available from 1 to 12 Exampl...

Страница 130: ...hostname maximum of 40 characters Possible value name hostname maximum of 40 characters Example Giga Switch hostname Company Company Igmp snooping set igmp_snooping Syntax set igmp_snooping status Des...

Страница 131: ...ription Disables the system s DHCP function Argument None Possible value None Example Giga Switch ip disable dhcp enable dhcp Syntax enable dhcp manual auto Description Enables the system DHCP functio...

Страница 132: ...y Argument ip ip address mask subnet mask gateway default gateway Possible value ip 192 168 1 2 or others mask 255 255 255 0 or others gateway 192 168 1 253 or others Example Giga Switch ip set ip 192...

Страница 133: ...168 95 1 1 log clear Syntax clear Description Clears the log data Argument None Possible value None Example Giga Switch log clear disable auto upload Syntax disable auto upload Description Disables t...

Страница 134: ...unction to query Up to 120 log records are supported Argument None Possible value None Example Giga Switch log show Tftp Server 0 0 0 0 Auto Upload Disable 1 Wed Apr 13 12 13 27 2005 Link Up Port 1 2...

Страница 135: ...44 set Syntax set mac alias Description Sets up the MAC alias entry Argument mac MAC address format 00 02 03 04 05 06 alias MAC alias name maximum of 15 characters Possible value None Example Giga Swi...

Страница 136: ...range of the ports to search for syntax 1 5 7 available from 1 to 12 mac mac address format 01 02 03 04 05 06 can be used vid vlan id from 1 to 4094 represents don t care 0 as untagged Possible value...

Страница 137: ...c learning MAC s age out time Argument age timer in seconds 0 10 to 65535 0 disables aging Possible value 0 10 to 65535 Example Giga Switch mac table maintain set aging 300 set flush Syntax set flush...

Страница 138: ...id 0 1 4094 VID must be zero if vlan mode is not tag based alias MAC alias name maximum of 15 characters Possible value mac mac address port 0 8 vid 0 1 4094 alias MAC alias name Example Giga Switch...

Страница 139: ...c show filter Static Filtering Entry Total 1 item s 1 mac 00 33 03 04 05 06 vid alias ccc show forward Syntax show forward Description Displays the static forward table Argument None Possible value No...

Страница 140: ...ting explanation for setting the management policy records Argument name value ACL entry name vid value VLAN ID ip value IP range port value Incoming port type value Access type action value a ccept o...

Страница 141: ...68 1 80 Type SNMP Action Deny Port 1 2 Giga Switch management delete 1 Giga Switch management show Security rule list is empty now edit the specific management policy entry Available range of 1 to 655...

Страница 142: ...ple h ttp s nmp t elnet or any action value No default and it must be set Example Giga Switch management edit 1 Giga Switch management edit 1 set name Tom vid 2 ip 192 168 1 30 192 168 1 80 port 1 2 t...

Страница 143: ...poe set priority 1 12 2 set state Syntax set state port range state Description To set the PoE state on ports Argument port range which port s you want to set syntax 1 5 7 available from 1 to 24 stat...

Страница 144: ...rcuit Port Off X X X X X X X X X X X X Over Temp Protection X X X X X X X X X X X X Power Management Port Off X X X X X X X X X X X X Port No 13 14 15 16 17 18 19 20 21 22 23 24 Port On X X X X X X X...

Страница 145: ...Normal 0 0 0 0 14 Normal Enable Normal 0 0 0 0 15 Normal Enable Normal 0 0 0 0 16 Normal Enable Normal 0 0 0 0 17 Normal Enable Normal 0 0 0 0 18 Normal Enable Normal 0 0 0 0 19 Normal Enable Normal...

Страница 146: ...capability Argument range syntax 1 5 7 available from 1 to 12 Possible value range 1 8 Example Giga Switch port disable state 1 2 enable flow control Syntax enable flow control range Description Enab...

Страница 147: ...ex 10M Full 100half set speed duplex 100M Half 100full set speed duplex 100M Full 1Gfull set speed duplex 1G Full Possible value range 1 to 12 port speed auto 10half 10full 100half 100full 1Gfull Exam...

Страница 148: ...FP module information Argument port The switch s SFP port available from 7 8 Possible value port 7 8 Example Giga Switch port show sfp 7 Port 7 SFP information Connector Type SFP LC Fiber Type Multi m...

Страница 149: ...vance layer4 Syntax set advance layer4 port range tcp udp port default match Description Sets the ports class in Layer 4 qos advanced mode Argument port range port range syntax 1 5 7 available from 1...

Страница 150: ...nge class Description Sets ports class on IP DiffServe qos Argument ds range dscp field syntax 1 5 7 available from 0 to 63 class class of service setting 1 high 0 low Possible value ds range 0 to 63...

Страница 151: ...ge 1 to 12 class 1 or 0 Example Giga Switch qos set port 1 8 1 set pri tag Syntax set pri_tag port range tag range class Description Sets ports class on vlan tag based qos Argument port range port ran...

Страница 152: ...ws 5 prioritize streaming Audio Video 6 prioritize databases Oracle IBM DB2 SQL Microsoft Possible value 0 6 Example Giga Switch qos set simple layer4 2 set tos Syntax set tos port range tos range cla...

Страница 153: ...high 18 high 19 high 20 high 21 high 22 high 23 high 24 high 25 high 26 high 27 high 28 high 29 high 30 high 31 high 32 high 33 high 34 high 35 high 36 high 37 high 38 high 39 high 40 high 41 high 42...

Страница 154: ...ble snmp Giga Switch snmp disable set ability enable Syntax enable set ability enable snmp Description Enable activates snmp or set community Argument None Possible value None Example Giga Switch snmp...

Страница 155: ...ription Displays the SNMP configuration Argument None Possible value None Example Giga Switch snmp show SNMP Enable Get Community public Set Community private Enable Trap Host 1 IP Address 192 168 1 1...

Страница 156: ...ga Switch stp enable MCheck Syntax MCheck range Description Forces the port to transmit RST BPDUs RST is the Rapid Spanning Tree IEEE802 1d standard BPDU is an abbreviation for Bridge Protocol Data Un...

Страница 157: ...40 Forward Delay 4 to 30 Example Giga Switch stp set config 61440 2 20 15 set port Syntax set port range path cost priority edge_port admin p2p Description Sets up the STP port information Argument r...

Страница 158: ...Syntax show config Description Displays the STP configuration Argument None Possible value None Example Giga Switch stp show config STP State Configuration Spanning Tree Protocol Enabled Bridge Prior...

Страница 159: ...to 8 DISCARDING 2000000 128 No Auto show status Syntax show status Description Displays the STP status Argument None Possible value None Example Giga Switch stp show status STP Status STP State Enable...

Страница 160: ...e string Description Sets the switch s device name description Argument device name string length up to 40 characters Possible value device name A b c d z and 1 2 3 etc Example Giga Switch system set...

Страница 161: ...rsion v1 01 Firmware Version v2 14 Hardware Mechanical Version v1 01 v1 01 Serial Number 030F03000003 Host IP Address 192 168 1 1 Host MAC Address 00 40 c7 de 00 e7 Device Port UART 1 TP 6 Dual Media...

Страница 162: ...ight saving Argument hr daylight saving hour range 5 to 5 MM daylight saving start Month 01 12 DD daylight saving start Day 01 31 HH daylight saving start Hour 00 23 mm daylight saving end Month 01 12...

Страница 163: ...the current time via Network Time Protocol NTP server This is used to synchronize a computer client or server s time to another server Argument ip ntp server ip address or domain name timezone time zo...

Страница 164: ...l trunk Syntax del trunk port range Description Deletes the trunking port Argument port range port range syntax 1 5 7 available from 1 to 12 Possible value port range 1 to 12 Example Giga Switch trunk...

Страница 165: ...ctive set the LACP to active mode passive set the LACP to passive mode active LACP Possible value port range 1 to 12 method static lacp group 1 8 active LACP active passive Example Giga Switch trunk s...

Страница 166: ...ty MAC Address System Priority MAC Address 32768 00 40 c7 e8 00 02 32768 00 00 00 00 00 00 Port Key Trunk Status Port Key 2 257 2 0 show lacp priority Syntax show lacp priority Description Displays th...

Страница 167: ...port group name Description Deletes the port based vlan group Argument name which vlan group you want to delete Possible value name port vlan name Example Giga Switch vlan del port group VLAN 2 del t...

Страница 168: ...s you want to set syntax 1 5 7 available from 1 to 12 Possible value range 1 to 12 Example Giga Switch vlan disable sym vlan 5 8 enable drop untag Syntax enable drop untag range Description Drops the...

Страница 169: ...Q in Q function up link syntax 1 5 7 available from 7 to 8 only for metro mode vlan Possible value disable port tag metro double tag disable port tag metro double tag up link 25 or 26 or 25 26 Exampl...

Страница 170: ...ept a specific VID vid untag vid for hybrid port Possible value range 1 to 12 vid 1 to 4094 Example Giga Switch vlan set port role 5 hybrid 6 set pvid Syntax set pvid range pvid Description Sets the v...

Страница 171: ...ible value vid 1 to 4094 range 1 to 12 0 or 1 Example Giga Switch vlan set tag group 2 VLAN 2 2 5 6 8 0 show group Syntax show group Description Displays the vlan mode and vlan group Argument None Pos...

Страница 172: ...sable Access 3 5 Disable Disable Access 4 1 Disable Disable Access 5 5 Enable Disable Hybrid 6 6 5 Enable Disable Access 7 5 Enable Disable Access 8 5 Enable Disable Access vs disable Syntax disable D...

Страница 173: ...ole Syntax set role master slave Description Sets the role Argument master slave master act as master slave act as slave Possible value master slave master or slave Example Giga Switch vs set role mas...

Страница 174: ...Example Giga Switch vs show Virtual Stack Config State Enable Role Master Group ID group1 CHAPTER 5 CLI Management 171...

Страница 175: ...s are used on that switch Solution 2 Verify that the uplink function is enabled Problem The console interface doesn t appear on the console port connection Solution 1 The COM port default parameters a...

Страница 176: ...ccurs the components involved in the problem any particular application that when used appears to create the problem or make it worse 6 4 Shipping and Packaging If you need to transport or ship your 1...

Отзывы: