1101 and 1102 Secure Device Servers
724-746-5500 | blackbox.com
78
The outlet status is displayed and you can initiate the
Action
you want to take by selecting the appropriate icon:
Turn
ON
Turn
OFF
Cycle
Status
You will only be presented with icons for those operations that are supported by the
Target
you have selected.
Figure 8-4. Selected operations supported by target.
8.1.4 RPC Status
You can monitor the current status of your network and serially connected PDUs and IPMI RPCs.
Select the
Status: RPC Status
menu and a table with the summary status of all connected RPC hardware will be displayed.
Click on
View Log
or select the
RPCLogs
menu and you will be presented with a table of the history and detailed graphical information on the
selected RPC.
Click
Manage
to query or control the individual power outlet. This will take you to the
Manage: Power
screen.
8.2 Uninterruptible Power Supply Control (UPS)
You can configure all Black Box
console server
s to manage locally and remotely connected UPS hardware using Network UPS Tools.
Network UPS Tools (NUT) is a group of open source programs that provide a common interface for monitoring and administering UPS hardware.
These programs ensure safe shutdowns of the systems that are connected. NUT is built on a networked model with a layered scheme of drivers,
server, and clients (covered in some detail in
Chapter 8.2.6
).