Thank you for purchasing this Price Pfister product.  All Price Pfister products are carefully engineered, and factory tested to 

provide long trouble-free use under normal conditions.  This product is easy to install using basic tools and our easy to follow 

illustrated instructions.  If you have any questions regarding this product, call 1-800-Pfaucet (1-800-732-8238).

1   BEFORE PROCEEDING:

WARNING:

 Read all the instructions completely before proceeding.  Price 

Pfister recommends calling a professional if you are uncertain about installing 

this product!

This product should be installed in accordance with all local and state plumbing and 

building codes.

WATER SHUT-OFF:

Locate water supply inlets and shut off water supply valves.  These are usually 

found near water meter.

PREPARATION:

This Price Pfister Diverter was designed to use with Roman Tub Spouts and 

may be used with any supply valve that provides sufficient flow.  Have the basic 

tools ready for removal of old valve.  If you are replacing an existing Valve, 

disconnect the old valve and clean the mounting surface thoroughly.  Align and 

adjust water supply pipes to recommended dimensions.  For new construction, 

Install water supply pipes to recommended dimensions.

2   TOOLS RECOMMENDED:

● PTFE Plumber’s Tape  ● Slotted screwdriver 

● Phillips Screwdriver

● Adjustable wrench 

● Pipe Wrench 

● Flashlight

● Cloth 

● Thread Sealant

Some additional tools may be required.

3   CHECKING THE CONTENTS OF THE BOX

Upon opening the box, check to ensure that all of the following items are 

included.

    

A

  Diverter Valve              

B

  Pipe Cap                 

C

  Plastic Cover

I

f any of these items are missing, please contact Price Pfister Consumer Service 

at 1-800-Pfaucet (1-800-732-8238).

4   VALVE LOCATION

CAUTION:

  Be sure to position Diverter Valve Body (

4A

) correctly in wall, 

where the Supply Valve Shower Outlet is to connect to one of the Diverter 

Valve Body Inlets (

4B

).

The Depth (

4C

) from center of shower outlet (

4D

) to finished wall surface (

4E

is 2 

5

/

8

”.  Center Hole (

4F

) on wall is to be 2.00” Dia.  

Depending on supply valve used and location of Tub Spout and Shower Head, it 

may be necessary to offset either the supply pipes or the shower and tub risers.

2

4E

C

INLET

SECONDARY 

OUTLET

PRIMARY 

OUTLET

2.00” Dia.

A

B

4C

4A

4D

4B

4B

4F

INLET

5

/

8

” Dia.

Содержание Price Prister 15 Series

Страница 1: ...ema Para notificar a Pfister y recibir ayuda o servicio bajo esta garantía el comprador original puede 1 llamar al 1 800 Pfaucet 1 800 732 8238 para hablar con un representante de servicio al cliente que lo pueda ayudar o 2 escribir al departamento de servicio al consumidor c o Pfister Inc 19701 DaVinci Lake Forest CA 92610 U S A e incluir una descripción del problema el número del modelo su nombr...

Страница 2: ...g Valve disconnect the old valve and clean the mounting surface thoroughly Align and adjust water supply pipes to recommended dimensions For new construction Install water supply pipes to recommended dimensions 2 TOOLS RECOMMENDED PTFE Plumber s Tape Slotted screwdriver Phillips Screwdriver Adjustable wrench Pipe Wrench Flashlight Cloth Thread Sealant Some additional tools may be required 3 CHECKI...

Страница 3: ...lve Body Inlet 5E with Pipe Plugs 5F For Tub Shower connections do not plug Supply Valve Outlets WARNING When attaching threaded fittings use thread sealant or PTFE Plumber s tape according to manufacturer s instructions CAUTION When using iron pipes it is not recomended to reduce outlet pipe diameter 6 OUTLET INSTALLATION Connect Primary 6A and Secondary 6B Outlet pipes to Diverter Valve Body Out...

Страница 4: ...cañerías de suministro de agua a las dimensiones recomendadas En el caso de una instalación nueva instale las cañerías de suministro de agua a las dimensiones recomendadas 2 HERRAMIENTAS RECOMENDADAS Cinta de plomero de PTFE Destornillador ranurado Destornillador Phillips Llave ajustable Llave para tubos Linterna Paño Sellador de roscas Podrían necesitarse otras herramientas 3 VERIFICACIÓN DEL CON...

Страница 5: ...a 5F Para las conexiones de tina y ducha no tape las salidas de la válvula de suministro ADVERTENCIA Al instalar conectores roscados utilice cinta para plomero de PTFE para roscas de acuerdo con las instrucciones del fabricante PRECAUCIÓN Si está usando cañerías de hierro no se recomienda para reducir el diámetro de la cañería de salida 6 INSTALACIÓN DE LA SALIDA Conecte las cañerías de salida pri...

Страница 6: ...et ajustez les tuyaux d alimentation en eau afin qu ils aient les dimensions recommandées S il s agit d une nouvelle installation posez les tuyaux d alimentation en eau selon les dimensions recommandées 2 OUTILS RECOMMANDÉS Ruban pour tuyau en PTFE Tournevis pour écrou à fente Tournevis Phillips Clé réglable Clé à tube Lampe torche Chiffon Mastic de filetage Vous aurez éventuellement besoin d outi...

Страница 7: ...tuyau Ne bouchez pas les orifices de sortie de robinet d alimentation pour les raccordements de douche et de baignoire AVERTISSEMENT lorsque vous connectez des raccords filetés utilisez du ruban à tuyau fileté selon les instructions du fabricant ATTENTION lorsque vous utilisez des tuyaux en fer ne réduisez pas le diamètre du tuyau de sortie 6 INSTALLATION DES TUYAUX D ÉVACUATION Connectez les tuya...

Страница 8: ...15 IWD 19701 DaVinci Lake Forest CA 92610 Phone 1 800 Pfaucet www pfisterfaucets com 910 022 970 500 931 510 ...

Отзывы: