background image

continuous. If the power consumption is rated in amps AC, simply multiply by
the AC volts (115) to determine the wattage.

Resistive loads are the easiest for the inverter to run; however, it will not run larger
resistive loads (such as electric stoves and heaters), which require far more
wattage than the inverter can deliver. Inductive loads (such as TVs and stereos)
require more current to operate than do resistive loads of the same wattage rating.

For safety reasons, the unit will simply shut down if it is overloaded. To restart
the unit, simply remove the load. Then plug devices back into the inverter
making certain that the total load does not exceed 80 watts continuous.

Protective Features

The inverter monitors the following conditions:

Low Battery Voltage – this condition is not harmful to the inverter but could
damage the powered device, so the inverter automatically shuts down when the
internal battery pack becomes low of charge. This will be indicated by a flashing
red LED in the front panel before automatic shutdown of inverter.

Thermal Shutdown Protection – the unit will automatically shut down when the
unit becomes overheated. Manual reset will be necessary after the unit cools
down to restart unit.
Overload/Short Circuit Protection – the inverter will automatically shut down
when a short circuit occurs. Manual reset will be necessary to restart unit.
Note: The Bi-color Inverter Status LED Indicator will light red to indicate
Fault condition before automatic shutdown occurs.

OPERATING TIPS

The POWER TO GO

®

should only be operated in locations that are:

DRY – Do not allow water or other liquids to come into contact with the inverter.
COOL – Surrounding air temperature should be between –20°C and 40°C —
ideally between 15°C and 25°C (60 – 80°F). Keep the inverter away from direct
sunlight, when possible.
VENTILATED – Keep the area surrounding the inverter clear to ensure free air
circulation around the unit. Do not place items on or over the inverter during
operation. The unit will shut down if the internal temperature gets too hot. The
inverter will auto-reset after it cools down. Do not use inverter in a pocket.
SAFE – Do not use the inverter near flammable materials or in any locations that
may accumulate flammable fumes or gases. This is an electrical appliance that
can briefly spark when electrical connections are made or broken.

8

CPI100B_ManualEN_041307.qxp  6/25/07  2:13 PM  Page 8

Содержание POWER TO GO CPI100B

Страница 1: ...VAILABLE IN MOST CASES A BLACK DECKER REPRESENTATIVE CAN RESOLVE THE PROBLEM OVER THE PHONE IF YOU HAVE A SUGGESTION OR COMMENT GIVE US A CALL YOUR FEEDBACK IS VITAL TO BLACK DECKER Catalog Number CPI100B TO REDUCE THE RISK OF INJURY THE USER MUST READ AND UNDERSTAND THE INSTRUCTION MANUAL SAVE THIS MANUAL FOR FUTURE REFERENCE Cat CPI100B Form 90517192 April 07 Copyright 2007 Black Decker Printed ...

Страница 2: ...iance by cord or yank it to disconnect from receptacle Keep cord from heat oil and sharp edges DON T OVERREACH Keep proper footing and balance at all times DISCONNECT APPLIANCES Disconnect the appliance from the power supply when not in use before servicing and when changing accessories such as blades and the like AVOID UNINTENTIONAL STARTING Don t carry plugged in appliance with finger on switch ...

Страница 3: ...ates a potentially hazardous situation which if not avoided may result in minor or moderate injury CAUTION Used without the safety alert symbol indicates potentially hazardous situation which if not avoided may result in property damage WARNING RISK OF UNSAFE OPERATION When using tools or equipment basic safety precautions should always be followed to reduce the risk of personal injury Improper op...

Страница 4: ...an AC plug can become bent from misuse If an AC plug is improperly inserted into the AC outlet a bent prong can slip outside the inverter and become a shock hazard WARNING EXPLOSION HAZARD This equipment employs components that tend to produce arcs or sparks DO NOT use in compartments containing batteries or flammable materials Use of an attachment not supplied recommended or sold by manufacturer ...

Страница 5: ...he POWER TO GO Do not use the POWER TO GO with the following appliances a Small battery operated appliances like rechargeable flashlights some rechargeable shavers and night lights that are plugged directly into an AC receptacle to recharge b Battery chargers used in hand power tools These chargers display a warning label stating that dangerous voltages are present at the charger battery terminals...

Страница 6: ...nutes or 80 watts continuous Two 5 Volt DC USB Power Ports Built in Power Fault LED Indicator Battery Status LED Indicators Rechargeable NiMH Battery Pack 120 Volt AC Charging Port and Charging Adapter Tethered Protective Outlet Covers Electronic circuit protection prevents damage due to overload insufficient ventilation overheat condition Compact size efficient and quiet USB POWER PORTS 120 VOLT ...

Страница 7: ...s similar to the sine wave shape of utility power This type of waveform is suitable for most AC loads including linear and switching power supplies used in electronic equipment transformers and small motors The modified sine wave produced by this inverter has an RMS root mean square voltage of 115 volts Most AC voltmeters both digital and analog are sensitive to the average value of the waveform r...

Страница 8: ...neously plugged into the CPI100B does not exceed 80 watts continuous 120 Volt AC Outlet 1 Make sure the CPI100B is properly charged Turn the unit to the ON position Both Status LED Indicators will be lit solid green indicating proper operation of the unit 2 Plug the 110 120 volt AC appliance into the Inverter s two prong AC outlet and operate normally Note The CPI100B will not operate appliances a...

Страница 9: ...hut down when the unit becomes overheated Manual reset will be necessary after the unit cools down to restart unit Overload Short Circuit Protection the inverter will automatically shut down when a short circuit occurs Manual reset will be necessary to restart unit Note The Bi color Inverter Status LED Indicator will light red to indicate Fault condition before automatic shutdown occurs OPERATING ...

Страница 10: ...onger retain a charge For information on recycling this battery call toll free 877 822 8837 WARNINGS TO REDUCE THE RISK OF INJURY EXPLOSION Do not dispose of batteries in fire as this may result in an explosion Do not expose the unit containing a battery to fire or intense heat as it may explode TROUBLESHOOTING Common Audio Visual Problems Problem Buzzing Sound In Audio Systems Some inexpensive st...

Страница 11: ...tery Status LEDs are lit fault condition attempt manual but there is no AC power reset and reduce load LED indicators are off Hold ON OFF pushbutton for at unit may not be in the ON position least 1 second to turn unit ON Unit shuts down after a few Internal battery pack needs minutes internal battery voltage recharging refer to charging is low instructions on page 7 Common Power Output Problems U...

Страница 12: ...tailer from whom it was purchased provided that the store is a participating retailer Returns should be made within the time period of the retailer s policy for exchanges usually 30 to 90 days after the sale Proof of purchase may be required Please check with the retailer for their specific return policy regarding returns that are beyond the time set for exchanges The second option is to take or s...

Страница 13: ... for 5 minutes 80 watts continuous USB Output 5 V DC 500mA each x 2 Batteries 1 2 AH NiMH Imported by Black Decker U S Inc 701 E Joppa Rd Towson MD 21286 U S A Vector Products Inc 4140 SW 28th Way Fort Lauderdale FL 33312 12 CPI100B_ManualEN_041307 qxp 6 25 07 2 13 PM Page 12 ...