background image

• Proper cooling is essential when operating this unit. Do not place it near a heat
source or in direct sunlight.

• The inverter may become uncomfortably warm, reaching 165° F (74° C) under
extended high power operation. During operation, keep it away from materials that
may be affected by high temperatures. Do not operate the CPI100B in a pocket.

• The cells inside the POWER TO GO

®

contain toxic substances. Do not use the

POWER TO GO

®

if the casing is broken or if it emits an unusual odor, produces

excessive heat, or leaks. Avoid contact with any substance that leaks from the
POWER TO GO

®

. Do not attempt to open the POWER TO GO

®

. Do not insert any

object into the POWER TO GO

®

or use any device to pry at the casing.

• Do not insert foreign objects into the AC outlet or USB charging ports. This
may cause unit to short circuit.

• Grip the inverter carefully when inserting or removing an AC plug. Keep your
fingers clear of the AC outlet. Ensure that your fingers do not contact the prongs of
an AC plug when the plug is partially inside the inverter.

CAUTION: Some chargers for small rechargeable batteries can be damaged

if connected to the POWER TO GO

®

. Do not use the POWER TO GO

®

with the

following appliances:

a) Small battery-operated appliances like rechargeable flashlights, some

rechargeable shavers, and night lights that are plugged directly into an AC
receptacle to recharge.

b) Battery chargers used in hand power tools. These chargers display a

warning label stating that dangerous voltages are present at the charger
battery terminals.

• Pull charging cord by plug rather than cord when disconnecting the 120 Volt
AC Charging Adapter from the unit.
• Use only the supplied 500 mA 120 Volt AC Charging Adapter to recharge this
unit. Contact manufacturer for replacement.

• ALWAYS turn the POWER TO GO

® 

OFF when it is not in use.

CAUTION: Do not connect live AC power to the POWER TO GO

® 

outlets. This

will damage the inverter, and the damage is not covered by warranty.
• Do not connect any AC load that has its neutral conductor connected to
ground to the POWER TO GO

®

inverter.

• This inverter will not operate high wattage appliances or equipment that
produce heat, such as hair driers, microwave ovens and toasters. It only powers
up to 100 watts for 5 minutes, or 80 watts continuous.
• This unit has not been tested for use with medical devices.
•  Read this Instruction Manual before using this unit.

SAVE THESE INSTRUCTIONS

4

CPI100B_ManualEN_041307.qxp  6/25/07  2:13 PM  Page 4

Содержание POWER TO GO CPI100B

Страница 1: ...VAILABLE IN MOST CASES A BLACK DECKER REPRESENTATIVE CAN RESOLVE THE PROBLEM OVER THE PHONE IF YOU HAVE A SUGGESTION OR COMMENT GIVE US A CALL YOUR FEEDBACK IS VITAL TO BLACK DECKER Catalog Number CPI100B TO REDUCE THE RISK OF INJURY THE USER MUST READ AND UNDERSTAND THE INSTRUCTION MANUAL SAVE THIS MANUAL FOR FUTURE REFERENCE Cat CPI100B Form 90517192 April 07 Copyright 2007 Black Decker Printed ...

Страница 2: ...iance by cord or yank it to disconnect from receptacle Keep cord from heat oil and sharp edges DON T OVERREACH Keep proper footing and balance at all times DISCONNECT APPLIANCES Disconnect the appliance from the power supply when not in use before servicing and when changing accessories such as blades and the like AVOID UNINTENTIONAL STARTING Don t carry plugged in appliance with finger on switch ...

Страница 3: ...ates a potentially hazardous situation which if not avoided may result in minor or moderate injury CAUTION Used without the safety alert symbol indicates potentially hazardous situation which if not avoided may result in property damage WARNING RISK OF UNSAFE OPERATION When using tools or equipment basic safety precautions should always be followed to reduce the risk of personal injury Improper op...

Страница 4: ...an AC plug can become bent from misuse If an AC plug is improperly inserted into the AC outlet a bent prong can slip outside the inverter and become a shock hazard WARNING EXPLOSION HAZARD This equipment employs components that tend to produce arcs or sparks DO NOT use in compartments containing batteries or flammable materials Use of an attachment not supplied recommended or sold by manufacturer ...

Страница 5: ...he POWER TO GO Do not use the POWER TO GO with the following appliances a Small battery operated appliances like rechargeable flashlights some rechargeable shavers and night lights that are plugged directly into an AC receptacle to recharge b Battery chargers used in hand power tools These chargers display a warning label stating that dangerous voltages are present at the charger battery terminals...

Страница 6: ...nutes or 80 watts continuous Two 5 Volt DC USB Power Ports Built in Power Fault LED Indicator Battery Status LED Indicators Rechargeable NiMH Battery Pack 120 Volt AC Charging Port and Charging Adapter Tethered Protective Outlet Covers Electronic circuit protection prevents damage due to overload insufficient ventilation overheat condition Compact size efficient and quiet USB POWER PORTS 120 VOLT ...

Страница 7: ...s similar to the sine wave shape of utility power This type of waveform is suitable for most AC loads including linear and switching power supplies used in electronic equipment transformers and small motors The modified sine wave produced by this inverter has an RMS root mean square voltage of 115 volts Most AC voltmeters both digital and analog are sensitive to the average value of the waveform r...

Страница 8: ...neously plugged into the CPI100B does not exceed 80 watts continuous 120 Volt AC Outlet 1 Make sure the CPI100B is properly charged Turn the unit to the ON position Both Status LED Indicators will be lit solid green indicating proper operation of the unit 2 Plug the 110 120 volt AC appliance into the Inverter s two prong AC outlet and operate normally Note The CPI100B will not operate appliances a...

Страница 9: ...hut down when the unit becomes overheated Manual reset will be necessary after the unit cools down to restart unit Overload Short Circuit Protection the inverter will automatically shut down when a short circuit occurs Manual reset will be necessary to restart unit Note The Bi color Inverter Status LED Indicator will light red to indicate Fault condition before automatic shutdown occurs OPERATING ...

Страница 10: ...onger retain a charge For information on recycling this battery call toll free 877 822 8837 WARNINGS TO REDUCE THE RISK OF INJURY EXPLOSION Do not dispose of batteries in fire as this may result in an explosion Do not expose the unit containing a battery to fire or intense heat as it may explode TROUBLESHOOTING Common Audio Visual Problems Problem Buzzing Sound In Audio Systems Some inexpensive st...

Страница 11: ...tery Status LEDs are lit fault condition attempt manual but there is no AC power reset and reduce load LED indicators are off Hold ON OFF pushbutton for at unit may not be in the ON position least 1 second to turn unit ON Unit shuts down after a few Internal battery pack needs minutes internal battery voltage recharging refer to charging is low instructions on page 7 Common Power Output Problems U...

Страница 12: ...tailer from whom it was purchased provided that the store is a participating retailer Returns should be made within the time period of the retailer s policy for exchanges usually 30 to 90 days after the sale Proof of purchase may be required Please check with the retailer for their specific return policy regarding returns that are beyond the time set for exchanges The second option is to take or s...

Страница 13: ... for 5 minutes 80 watts continuous USB Output 5 V DC 500mA each x 2 Batteries 1 2 AH NiMH Imported by Black Decker U S Inc 701 E Joppa Rd Towson MD 21286 U S A Vector Products Inc 4140 SW 28th Way Fort Lauderdale FL 33312 12 CPI100B_ManualEN_041307 qxp 6 25 07 2 13 PM Page 12 ...

Отзывы: