installation  and  thence  to  an  independent  earth  connection  in  compliance  with  EN  60335-1  and/or  local 
codes.

The  electric  motor,  all  the  related  switches,  interior  lights  and  the  timer/buzzer,  are  all  connected  through 
the  6ft  (1829  mm)  power  supply  cord  located  at  the  rear  of  the  oven.  The  supply  cord  must  be  plugged  into  a 
properly  grounded  three-prong  receptacle. 

DO

 

NOT  CUT  OR  REMOVE  THE  GROUNDING  PRONG 

FROM  THE  PLUG.

Normal  factory  connections  are  made  for  115  volts  AC.,  60  Hz.  Service  in  USA  and  Canada  or  230Volts  AC, 
50  Hz  service  in  European  Community  Countries.  Other  voltages  can  be  supplied  upon  request.  Electrical 
characteristics  of  this  unit  can  be  found  on  the  rating  plate  located  on  the  right  side  of  the  unit.

This  unit  is  provided  with  a  permanently  lubricated  electric  motor.  A  wiring  diagram  may  be  found  on  the 
back  of  the  service  panel  on  the  right  hand  side  and  in  this  manual.

G.  FLUE  CONNECTION  -  VENTILATION:

(a)  INSTALLATION    UNDER  VENTILATION  HOOD  (STANDARD):

If  the  oven  is  not  vented  directly  and  is  installed  under  a  ventilation  hood,  use  the  flue  diverter  (Fig.  1) 
supplied.  Local  inspectors  and  ventilation  specialist  should  be  consulted  so  that  the  design  and  the 
installation

 

of

 

the

 

hood

 

conforms

 

to

 

local/municipal

 

codes.

In  U.K.  ventilation  requirements  as  detailed  in  B.S.  5440  should  be  followed.

(b)  OPTIONAL  DIRECT  VENTING-NOT  AVAILABLE  FOR  EUROPEAN  COMMUNITY  COUNTRIES:

If  direct  venting,  a  flue  adapter  and  a  draft  hood  (fig.2)  are  required  to  be  installed.  These  prevent  the  flue 
gases  leaving  the  oven  from  being  affected  by  the  air  pressure  changes  on  the  outside  of  the  flue  stack 
extending  out  of  the  building.  The  flue  pipe  from  the  draft  hood  must  not  run  downwards  at  any  point  from 
the  oven  to  the  final  outlet.  It  should  always  slant  slightly  upwards.  For  best  results  it  should  rise  straight  up

NOTE:  DO  NOT  PUT  A  DAMPER  IN  THE  FLUE  AND  DO  NOT  CONNECT  A  BLOWER  DIRECTLY  TO 
THE  FLUE.

If  the  flue  runs  directly  to  the  free  air  outside  the  building,  use  a  wind  deflector  or  a  UL  listed  vent  cap  at  the 
end  of  the  pipe.  Termination  of  the  vent  must  be  at  least  two  feet  above  the  highest  part  of  the  roof  within  ten 
feet.  REF:  AGA  CATALOG  NO.  XH0474.

H.  BURNER  OPERATION:

The  oven  burner  flame  should  always  have  a  blue  appearance.  This  indicates  a  good  mixture  of  air  and  gas. 
When  using  LP  gas  the  flame  will  have  a  blue  yellow  appearance.  There  may  be  intermittent  yellow-orange 
flame  noticed.  This  is  caused  by  dust  particles  burning  in  the  flame.

I.  SYSTEM  CHECK  -    ROTARY  CONTROL:

I) 

Open  the  oven  door.

2) 

Turn  Selector  Switch  to  'Hi'.  The  indicator  light  near  Selector  Switch  and  oven  light  will  illuminate.

3) 

Close  the  door.  Oven  lights  will  go  off  and  fan  will  run.  Make  sure  fan  is  rotating  clockwise  looking 
from  front.

4) 

Press  Oven  Light  switch.  Oven  light  will  go  on  and  will  go  off  as  switch  is  released.

5) 

Turn  Gas  Cock  Dial  to  'ON'  position.(only  for  USA  &  Canada)

6) 

Turn  the  thermostat  knob.  The  indicator  light  near  the  thermostat  will  Illuminate  and  the  burners  will 
come  on.

7) 

Turn  the  Timer  Knob  and  set  a  time  of  2  minutes.  At  the  end  of  2  minutes,  you  should  hear  the 
buzzer.  Turn  the  timer  knob  to  '0'  to  reset.

8) 

Open  the  oven  doors.  Oven  lights  will  go  on,  and  burners  and  fan  will  go  off.

9) 

Turn  Selector    switch  to  'Cool  Down'  position.    The  fan  will  run  to  cool  down  the  oven.

10) 

Turn  Selector  Switch  to  '0'  position.

5

Содержание CO1-G

Страница 1: ...xposure to smoke or fumes may cause nausea or dizziness Note Only Pizza or Bread can have direct contact with ceramic decks All other food products must be placed in a pan or container to avoid direct contact with ceramic decks This equipment has been engineered to provide you with year round dependable service when used according to the instructions in this manual and standard commercial kitchen ...

Страница 2: ... supplied for stacked installations A carton containing a Flue Adapter and or an optional Draft Hood for Direct Venting Not available for European Community Countries B SET UP MOUNTING NOTE This appliance must be installed by competent person in accordance with the rules in force In the U K Corgi registered installers including the regions of British Gas undertake to work to safe and satisfactory ...

Страница 3: ...lts 3 Insert Open Rack Shelf and tighten into place with eight 3 8 16 screws washers and nuts 4 Position Rack Supports and tighten in place using 4 each of Flat washers and 5 16 18 Hex Nuts To assemble over a Base Cabinet 1 Tilt cabinet over onto the left hand side Attach two mounting plates to the right underside and screw 6 legs into the center holes 2 Lift up left hand side of the base cabinet ...

Страница 4: ...e European Community countries should be as below GasType Supply Pressure G20 20 mbar G25 25 mbar G20 25 20 25 mbar G30 30 or 50 mbar depending on country G31 30 37 or 50 mbar depending on country A separate shut off valve for each oven must be provided It should be as close as possible to the place where the gas line goes into the oven It must be located such that it is easily accessible When sta...

Страница 5: ...anges on the outside of the flue stack extending out of the building The flue pipe from the draft hood must not run downwards at any point from the oven to the final outlet It should always slant slightly upwards For best results it should rise straight up NOTE DO NOT PUT A DAMPER IN THE FLUE AND DO NOT CONNECT A BLOWER DIRECTLY TO THE FLUE If the flue runs directly to the free air outside the bui...

Страница 6: ...n when done B TIMED COOKING ROTARYCONTROL I Close the oven doors 2 Turn Selector Switch to HI or LO position The indicator light near the Selector Switch will be illuminated 3 Turn the thermostat knob to the desired cooking temperature 4 Upon reaching the set temperature the indicator light near the thethermstat will go out 5 Load the oven with product to be cooked 6 Turn the timer knob to the des...

Страница 7: ... NOT USE STEELWOOL Clean The Stainless Steel Interior Baked on splatter oil grease or discoloration on the stainless steel inside of the oven may be removed with stainless steel cleaner or any other similar cleaning agent NEVER use vinegar or any corrosive cleaner Use only cleaners approved for stainless steel NEVER use cleaning solvents with a hydrocarbon base NEVER use a wire brush steel or abra...

Страница 8: ...8 wheel puller bolt supplied in center of hub See Fig 3 Clean The Porcelain Interior Porcelain enamel interiors are designed to be as maintenance free as possible However for best results the oven should be cleaned regularly Enameled interiors can be easily cleaned with oven cleaners KEEP CLEANING FLUIDS AWAY FROM ELECTRICAL WIRES LIGHT SOCKETS SWITCHES AND CONTROLPANEL OVEN EXTERIOR Clean The Ext...

Страница 9: ... 2 13 x 1 HEX HEAD BOLT 12 REQUIRED 5 16 FLATWASHER 4 REQUIRED 5 16 18 HEX NUT 4 REQUIRED OPEN RACK SHELF RACK SUPPORT 3 8 16 x 3 4 TRUSS HEAD SCREW w NUT WASHER 8 REQUIRED 5 ILLUSTRATIONS CONTINUED CONTROL PANEL ROTARY CONTROL Figure 3 Figure 4 Figure 5 9 SELECTOR SWITCH PILOT LIGHT GREEN SELECTOR SWITCH THERMOSTAT PILOT LIGHT AMBER THERMOSTAT LIGHTS SWITCH TIMER STEAM INJECTION SWITCH ...

Страница 10: ...O GC 20 NO COM L2 L1 NO NC ooox ooxo oxoo oxxo 24V 120V BUZZER TIMER M450 1 2 4 S Fan Rotary Switch Off Low High Cool Down Door Switch Solenoid Valve Amber Pilot Light Thermostat Green Pilot Light Temperature Controller Power RAM CO Power Timer Coil Steam Potentiometer Factory Set 8 Seconds Coil Steam Button Ignition Module Valve 2 Speed Motor Interior Lights Momentary Switch Interior Lights 10 ...

Страница 11: ...ame sensor ground valve hot thermostat L1 24vac ignitor 3 4 5 6 2 1 7 steam switch steam timer potentiometer blk yel red blu solenoid valve FF PILOT IN 120v 24v ignitor 120VAC 1 2 3 4 S Rotary Switch Door Switch Pilot Light Thermostat Pilot Light Power RAM LO HI COM 7 WIRING DIAGRAM ROTARY CONTROL CO1 G 11 ...

Страница 12: ...nsor L1 Ignitor Sensor RAM COM HI LO Door Sw NC NO Lights Switch CO VALVE 120 V Grn Ylo CH 100 FAST T12 T6 T7 T13 T9 T8 T5 T4 T3 T2 24V 120V T11 T10 RTD Probe Rotary Switch P2 P3 P4 P1 1 2 3 4 Closed Open 120 V L1 N BLK 1 WT 2 BLK 11 BLK 3 BLK 5 WT C2 WT 4 BLK S WT S2 WT S1 GREY 7 8 R1 R2 Orange Black A B BLK 13 BLUE 10 BLK C1 BLK 23 BLK 15 GREY 26 27 BLK 17 BLUE 12 BLK WT BLK 21 BLK 19 BRWN BRWN ...

Страница 13: ...CE LP 12 E3149X Top Left Angle Open Rack Stand 34 R1116A Manifold 13 T3051X Left Rack Support Open Rack Stand 35 S3228A Flange Bearing 4 14 T3052X Right Rack Support Open Rack Stand 36 S3231X Door Chain Assy Complete 15 T8075X Bottom Shelf w Hdwr Open Rack Stand 37 S3226A Door Chain Rod Short 16 R3180A 48 Burner Orifice Spud Nat 38 S3227A Door Chain Rod Long 17 R3175A 57 Burner Orifice Spud LP 39 ...

Страница 14: ...69 70 71 72 74 75 75 75 73 76 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 16 ER B K S A ER B K S A I P E D RI P E D R w S r i o tc o h D 93 21 21 22 22 7 7 14 CO1 G Full Size Gas Convection Oven 864 963 3471 864 963 5316 800 927 6887 customerservice bkideas com fax US Canada web address PO Box 80400 Simpsonville SC 29680 0400 BKI WORLDWIDE Note When ordering ALWAYS specify Part Model Serial Volta...

Страница 15: ...ter 26 E3095X Baffle Plate Bracket Assy 4 74 M1335X Bell Audiolarm 27 Q1414A Screw Hex Hd 10x3 4 8 75 S1311X Knob 3 28 E3481X Combustion Chamber Front Center 76 M1352X Ckt Breaker 120 240V 15A 29 E3482X Combustion Chamber Front Left 77 30 E3511X Combustion Chamber Front Right 78 M1356A Solid State Relay CE 31 E3471K Door Switch Actuator 79 M1145X Transformer 120V 24V 32 M1102X Microswitch Rotary 8...

Страница 16: ...ONS Negligence or acts of God Thermostat calibrations after 30 days from equipment installation date Air and Gas adjustments Light bulbs Glass doors and door adjustments Fuses Adjustments to burner flames and cleaning of pilot burners Tightening of screws or fasteners Failures caused by erratic voltages or gas supplies Unauthorized repair by anyone other than a BKI Factory Authorized Service Cente...

Отзывы: