23
Inductance (Series mode)
Test Frequency: 100 / 120Hz
Range
Maximum
Display
Accuracy (DF<0.5)
Spec. Note
Inductance
DF
1000H
999.9H
1.0%+(Lx
/10000) %+5
2%+100/Lx+5
After open cal.
200H
199.99H
0.7%+(Lx
/10000)%+5
1.2%+100/Lx+5
-
20H
19.999H
0.7%+(Lx
/10000)%+5
1.2%+100/Lx+5
-
2000m
1999.9mH
0.7%+(Lx
/10000)%+5
1.2%+100/Lx+5
-
200mH
199.99mH
1.0%+(Lx
/10000)%+5
3%+100/Lx+5
After short cal.
20mH
19.999mH
2.0%+(Lx
/10000)%+5
10%+100/Lx+5
After short cal.
Test Frequency: 1 KHz
Range
Maximum
Display
Accuracy (DF<0.5)
Spec. Note
Inductance
DF
100H
99.99H
1.0%+(Lx
/10000) %+5
2.0%+100/Lx+5
After open cal.
20H
19.999H
0.7%+(Lx
/10000)%+5
1.2%+100/Lx+5
-
2000mH
1999.9mH
0.7%+(Lx
/10000)%+5
1.2%+100/Lx+5
-
200mH
199.99mH
0.7%+(Lx
/10000)%+5
1.2%+100/Lx+5
-
20mH
19.999mH
1.0%+(Lx
/10000)%+5
3.0%+100/Lx+5
After short cal.
2000
µ
H
1999.9
µ
H
2.0%+
(Lx/10000)%+5
10%+100/Lx+5
After short cal.