![BK Precision 5335B Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/bk-precision/5335b/5335b_user-manual_2759774039.webp)
Integral Operation Function
39
• Active power integralIn watt hour, displayed as WP (watt hours, the sum of positive and negative watt hours), WP+
(the consumption of positive watt hours) and WP- (the negative watt hours of feedback power).
• Current integralIn q, displayed as q (ampere hours, the sum of positive and negative ampere hours), q+ (the con-
sumption of positive ampere hours) and q- (the negative ampere hours of feedback power)
• Average active power integralIn watt, displayed as WPAV (average active power integral)
• Integration timeDisplayed as Time, in the format of hhhh:mm:ss.
7.2 Specification
• Save in case of power failureThe integral result can be kept in the memory even in case of power failure during
operation of the integral function. When the power supply is recovered and the integral function is disabled, the
integral result before power failure is displayed. When the power supply is recovered and the integral is rest, the
integral function is enabled again.
• Display resolutionThe maximum display resolution of the integral value is 99999. When the integral value reaches
100000, the decimal point will move automatically. For example, when 0.01mWh is added to 999.99mWh, 1.0000Wh
will be displayed.
• Display in case of overflowWhen the integral value meets the following overflow conditions, the integral function will
be disabled, and the integral time and integral value at this point will be kept.
– The integral time reaches the maximum value (10000hours).
– The integral values of WP, q and WPAV reach the maximum/minimum display integral values.
• Maximum/minimum display integral value
– Active power integral (WP):
±
99999Mwh
– Current integral (q):
±
99999MAh
– Average power integral (WPAV):
±
99999Mw
• Restricted implementationSettings of the following functions cannot be changed during integral operation.
Setting
Integral resetting Current integral status Integral interruption
Wiring
Executable
Unenforceable
Unenforceable
Measurement range
Executable
Unenforceable
Unenforceable
Filter
Executable
Unenforceable
Unenforceable
Averaging function
Executable
Unenforceable
Unenforceable
Synchronization
Executable
Unenforceable
Unenforceable
Data updating rate
Executable
Unenforceable
Unenforceable
Integral mode
Executable
Unenforceable
Unenforceable
Integral timer
Executable
Unenforceable
Unenforceable
Integral start
Executable
Unenforceable
Executable
Integral stop
Unenforceable
Executable
Unenforceable
Integral resetting
Executable
Unenforceable
Executable
Save operation
Executable
Executable
Executable
Hold operation
Executable
Executable
Executable
Single measurement operation Executable
Executable
Executable
Table 7.3
Settings configurability per mode