CONTROLS AND INDICATORS
10.
OUTPUT LEVEL Control
. Controls the amplitude of
the signal at the OUTPUT jack. Output level can be
decreased by approximately 20dB with this control.
11.
DC OFFSET Control
. Activated by the DC OFFSET
Switch (4). Clockwise rotation from center changes
the DC offset in a positive direction while
counterclockwise rotation from center changes the DC
offset in a negative direction.
12.
VCG/MOD INPUT Jack
. Controlled by
MODULATION OFF/ON Switch (33). When
MODULATION OFF is selected, jack is the Voltage
Controlled Generator input and permits external
control of generator output frequency by a DC voltage
input at this jack. A positive voltage will decrease
frequency. When MODULATION ON is selected, jack
becomes modulation input source.
13.
OUTPUT Jack
. Waveform selected by