Electrical Connections:  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Make the following Electrical Connections: 
 

For 120-277V / 347V 

Applications make the following Electrical Connections: 

a.  Connect the black luminaire lead to the line supply lead 
b.  Connect the white luminaire lead to the neutral supply lead  
c.  Connect the green or green and yellow ground lead to the supply ground lead 

Dimming Option: 

a.  Connect the violet dimming positive lead to the supply dimming positive lead 
b.  Connect the grey dimming negative lead to the supply dimming negative lead 

 

      Luminaire 

 

 

 

 

 

 

 

                      

 

 

    Line or Hot 1  

 

 

 

 

 

Line - Black  

 
 
 

 

  

 Green   

 

 

 

 

 

Ground - Green  

 
 
 

            Neutral or Hot 2   

 

 

 

 

 

Neutral - White 

 

 
 

 

 

Violet   

 

 

 

 

 

DIM (+) Violet                          

(Dimming Option) 
 

 

 

Grey 

 

 

 

 

 

 

DIM (+) Grey 

 

 

For 16/4 

both circuits must be connected to the same branch circuit, i.e. turning off the branch circuit protection will turn 

off both circuits of the luminaire.  

 

Electrical Disconnect Instructions:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The above electrical connections for the line 1 and neutral are made using the electrical disconnect that is connected to 
the LED driver. The connections are made as follows below, note that the disconnect is color coded for circuit wiring.  

a.  Black to Live 
b.  White to Neutral 

 
The intended wire sizes are as follows, with an 11-13 mm jacking length. 

a.  2 x AWG 18-12 

solid wire

 per pole 

b.  2 x AWG 16-12 <19 

stranded wire

 per pole 

 
If a wire is connected incorrectly the only way to remove the wire is by twisting the electrical disconnect and pulling firmly 
on the incorrect wire.  

 

 
 
 
 
 
 
 
 
 