background image

The light source of this luminaire is not replaceable when the light source reaches its end of 
life the whole luminaire shall be replaced.

ATTENTION!!!

4

5

(*) 

Maintained  operation:  The  luminaire  lights  its  illumination  source,  when  it  is  powered  by  the 

mains power supply or not

Non Maintained operation: The luminaire lights its illumination source,

 

only in mains power supply’s 

failure.

Cube M ST LED

SELFTESTING MAINTAINED

EMERGENCY LUMINAIRE

Cube

Technical Characteristics

OPERATION VOLTAGE

MAXIMUM POWER CONSUMPTION

BATTERY (Ni-MH)

MINIMUM POWER FACTOR

WIRE CROSS SECTION

MAX OPEN CIRCUIT VOLTAGE

Irated

Prated

U-OUT

MAXIMUM SUPPLY CURRENT

INSULATION BETWEEN SUPPLY & CONTROL TERMINALS
INSULATION BETWEEN SUPPLY & BATTERY CIRCUIT
BATTERY PROTECTION

CHARGE TIME

MINIMUM DURATION

LIGHT SOURCE
DEGREES OF COVER PROTECTION

LIGHT SOURCE LUMINOUS FLUX (MAINS / EMERGENCY)

INDICATIONS/CONTROLS

MAX CHARGE VOLTAGE

TRICKLE CHARGE VOLTAGE/CURRENT

MIN MAX. CHARGE CURRENT

MIN MAX. DISCHARGE CURRENT
MIN MAX. DISCHARGE VOLTAGE

PRODUCED IN ACCORDANCE WITH

OPERATION TEMPERATURE RANGE
CONTROL GEAR MAX.TEMPERATURE: tc

RELATIVE HUMIDITY

CONSTRUCTION MATERIAL

EXTERNAL DIMENSION (L x W x H)

WEIGHT
GUARANTEE

4.  Remove the old battery and place a new one of the same type and characteristics.
3.  Replace the removed parts.

1.  Remove the top cover (Step 1 of hanging or ceiling installation).
2.  Unscrew the 2 screws that hold the battery to its base.

It can be done only by a competent person and after the mains interruption

.

Battery Replacement

Module Connection & Dip Switch

1:

 Maintained operation 

(*) 

A:

 Including test device

B:

 Including remote test mode

NOTE:

 LED= Light Emitting Diode

X:

 Self contained

E:

 With non-replacable lamp(s) and/or battery 

LABELING EXPLANATION:

60:

 1 hour duration

C:

 Including inhibiting mode

480

: 8 hours duration

180:

 3 hours duration

X 1

6 0

A E

IP40

Maintained

Μ

370/270/110lm

Light output

1h/

3

h/8h

Duration

50

m

NM

Non-Maintained

Controlgear classification in accordance with IEC 62034: with automatic test function.

220-240V AC

 

/ 50-60Hz

6.4W / 6.6VA

2

2

0.5mm  - 2.5mm

33V

1h: 2.2W

1h: 200 mA

3h: 1.5W

3h: 141mA

8h: 57mA

8h: 0.6W

33V

29.2 mA

4.8V/2Ah

0.92

Basic insulation
Basic insulation

3 hours

370/270lm

310-490mA

190-210mA

5.8V/70mA

6V

16h

4-6V

8 hours

360/110lm

170-191mA

hour

370/370lm

438-700mA

16 power

 

LEDs

LED Charge, Lamp Fault LED, Battery Fault LED/Test BUTTON

IP40

Deep discharge and overcharge protection / the control gear will recharge the battery normally after the test of 22.3

o

5

 to 40  C

o

53  C at PSU1

Aluminium, ABS/PC

PC, Acrylic Plate

2326gr.

310 x 310 x 330 mm

Up to 95% 

4 years

EN 60598-1, EN 60598-2-22, EN 55015, EN 61547, 
EN 61000-3-2, EN 61000-3-3

1

3

4

2

Module connection

ON

1 2 3 4

Maintained operation

(default position)

ON

1 2 3 4

Non-maintained operation

ON

1 2 3 4

ON

1 2 3 4

ON

1 2 3 4

1h

(default position)

3h

8h

Dip Switch (DS1) Settings

Autonomy duration selection

Technical label installation

Changing the operating mode

The user can select one of the 3 available minimum autonomy durations: 1 hour, 3 hours and 8 hours. The selection 
must be done while the luminaire is disconnected from AC and battery supplies. The selection is achieved through 
Switches 2 & 3 of DS1. Switch 1 is not used. 

Two additional labels are included in the package, one for 3 hours duration (180) and one for 8 hour duration (480). 
Depending on the selected duration, the installer must cover the default 1 hour (60) printing with one that has the 
required duration. Please take notice of the orientation of the label.

The control of maintained or non maintained operation of the luminary is achieved through Switch 4 of DS1. For 
maintained operation, switch number 4 must be in ON position. For non-maintained operation,switch number 4 
must be in OFF position.

Honeywell Life Safety AS

http://www.hls-nordic.com 

Po. Box 3514, N-3007 Drammen, Norway

Отзывы: