GENERAL
This luminaire is used in places with low
o
t e m p e r a t u r e ( - 2 0 C ) w h e r e e m e r g e n c y
luminaires are needed.
Each illumination sign must be permanently
connected to mains power supply
.
In normal
operation the led strip lights and the battery is
charging.
In case of a mains power supply
failure the illumination sign will light the led
strip automatically in emergency mode. When
the mains power supply is restored the device
turns to normal operation.
INSTALLATION
To install the luminaire follow the installation
instructions on page 3.
Battery Charging
The battery charging is completely controlled
.
In this case, is
achieved the perfect battery
maintenance
,
as well as the elongation of its
duration
.
When the battery has completely
charged
,
it charges with a maintenance
current.
Battery Cut-off
The luminaire enters in this operation when the
mains power supply fails
and battery has lost
its
energy
.
During
this
operation
the
illumination sign enters the idle state
and
battery consumption is negligible, in order to be
protected from deep discharge.
Manual
Test
The manual test can be conducted only if the
mains power supply and the battery is
connected. By pressing the TEST/RESET
button briefly (page 3) an emergency operation
test is initiated. During this test period all
indication LEDs are OFF.
Automatic Operational Test
This test includes all the operations that provide
the manual test and is conducted automatically
every 15 days. In order to be performed, the
mains power supply and the battery should be
connected.
Manual Autonomous Test
If the Test button is pressed for a period
between 5 to 10 seconds (with the battery fully
charged), the illumination sign will enter in
counting autonomy condition.
If the battery is
not fully charged this command is ignored
. The
BATTERY
FAULT
blinks
during
the
measurement, indicating this process to the
user. This measurement duration is equal with
the nominal autonomous duration of the
illumination sign (1.5 hour or 3 hours) and at the
end of the process, if the measured duration
was at least the nominal autonomous duration,
the BATTERY FAULT is turned OFF, in the other
hand stays continuously ON indicating to the
Page
1
from
5
92
3
9390
16
_09_00
7
WATERPROOF SELF TESTING MAINTAINED EMERGENCY LUMINAIRES
ΤΕΧΝΙΚΑ ΧΑΡΑΚΤΗΡΙΣΤΙΚΑ
90 min
Charge, Lamp fault, Battery fault
,
TEST button
EN 60598-1, EN 60598-2-22
, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3
31W / 33
VA
(
<0°C
)
3
.
6
V / 2Ah
GR-938/30L/LT
180 min
24h
From overcharge and deep discharge
4 years
IP
65
2
80lm
/
2
3
0
lm
White LEDs
o
-20 to
+
40 C
Up to 95%
Bayblend FR3010
,
transparent
polycarbonate
3 years
(1
year for the battery
)
940gr.
1050gr.
32W /
3
5
VA
(
<0°C
)
3
.
6
V / 4Ah
220-240VAC
50-60Hz
363 x 145 x 73 mm
GR-93
9
/30L/LT
OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY
EXTERNAL DIMENSIONS
CONSTRUCTION MATERIALS
TYPICAL WEIGHT
GUARANTEE
OPERATION VOLTAGE
MAXIMUM POWER CONSUMPTION
CHARGING TIME
INDICATIONS
-
CONTROLS
BATTERY PROTECTION
EXPECTED BATTERY LIFETIME
MINIMUM AUTONOMOUS DURATION
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH
ILLUMINATION (MAINS / EMERGENCY)
ILLUMINATION SOURCE
BATTERIES (Ni-ΜΗ)
TECHNICAL CHARACTERISTICS
(for LED MODULE Specifications see page 4)
Thank you for your trust in our products.
Olympia Electronics - European manufacturer
.