SRP-F310/312
Rev. 1.01
BIXOLON
- 85 -
•
The error correction code word calculated by modulus 929.
•
Pad codeword.
■
When automatic processing (Function 065) is specified, the number of columns is calculated using the following
information:
•
Current printing area
•
Module width (Function 067)
•
Option setting (Function 070)
•
Codeword in the data area
•
The maximum number of columns is 30.
■
When auto processing (Function 066) is specified in page mode, the number of rows is calculated using the following
information:
•
Current printing area
•
Module height (Function 068)
•
Codeword in the data area
•
The maximum number of rows is 90.
■
Except for character size and upside-down printing mode, none of print mode such as emphasized, double-strike, etc,
affects the printing of the symbol.
■
In standard mode, the paper feed amount set by the paper feed setting command does not affect printing of the
symbol. The printing position returns to the left side of the printable area after printing the symbol.
■
In page mode, the printer stores the symbol data in the print buffer without executing actual printing.
■
The quiet zone is not included in the printing data. Be sure to include the adequate quiet zone for executing of this
command.
•
The quiet zone means the spaces surrounding the symbol such as upper, lower, left, and right spaces.
Differences:
None