SRP-F310/312
Rev. 1.01
BIXOLON
- 82 -
<Function 070> GS ( k pL pH cn fn m (fn=70)
Code:
ASCII
GS
(
k
pL
pH
cn
fn
m
Hex
1D
28
6B
03
00
30
46
m
Decimal
29
40
107
3
0
48
70
m
Range:
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=48
fn=70
m=0,1
Default:
m = 0
Description:
This command selects the option for PDF417.
m
Function
0
Select the standard PDF417
1
Select the simplified PDF417
Remarks:
■
Settings of this function affect the processing of Functions 081.
■
When simplified PDF417 symbol is canceled, standard PDF417 symbol is automatically selected.
■
The setting of this command remains effective until ESC @, printer reset or power cycling is executed.
Differences:
None