<Function 066> GS ( k pL pH cn fn n (fn=66)
Code:
ASCII
GS
(
k
pL
pH
cn
fn
n
Hex
1D
28
6B
03
00
30
42
n
Decimal
29
40
107
3
0
48
66
n
Range:
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=48, fn=66
n=0, 3 ≤ n ≤ 90
Default:
n = 0
Description:
■
This command specifies the number of rows in the data area of PDF417.
•
When n=0, automatic processing is set
•
When n is not 0, the number of rows is set to n rows.
Remarks:
■
Settings of this function affect the processing of Functions 081.
■
With auto processing (n=0) specified, the maximum number of rows is set to 90.
■
With auto processing (n=0) specified, the number of rows is calculated by using the following information:
•
Printing area when processing Functions 081
•
Module height (Function 068)
■
The setting of this command remains effective until ESC @, printer reset or power cycling is executed.
Differences: