Manual-calibration of media detection can be used when the printer cannot detect a media gap (or black
mark) even after auto-calibration has been executed.
Users can calibrate sensor parameters in detail by using the utility program provided by the manufacturer.
Unified Label Utility-II installation files and manuals are provided on the BIXOLON official website.
(http://www.bixolon.com)
Please refer to Unified Label Utility-II manual for details.
Please make sure the printer is connected and execute the utility program.
Please the Calibration Setting Manager Button after setting the interface type.
1) Select the sensing type and input the label length by millimeter and click on “Check Sensing Value” tap.
Then printer starts to calibrate.
2) Printer will print the scanned values after calibration and the values will appear on the Screen.
3) Optimal sensing values will appear in black bold letters on the left of the utility screen and select one of
the values and click on “Save Calibration”
4) If chosen value does not work properly, please try the other values among the black bold letters.
5) To go back to the initial value, please click on “Cancel Calibration”
Ver. 1.01
- 13 -
Содержание SRP-E770III Series
Страница 1: ...Service Manual Label Printer Ver 1 01 SRP E770III...
Страница 30: ...SRP E770III 4 2 Block Diagram Ver 1 01 30...
Страница 51: ...SRP E770III 7 1 2 LED dose not light Ver 1 01 51...
Страница 55: ...SRP E770III 7 1 6 Data from host is not printed normal Ver 1 01 55...
Страница 56: ...SRP E770III 7 2 Power Problem Ver 1 01 56...
Страница 57: ...SRP E770III 7 3 System Problem Ver 1 01 57...
Страница 58: ...SRP E770III 7 4 Panel PBA and Media Sensor Problem Ver 1 01 58...
Страница 60: ...SRP E770III 7 6 RS 232C Serial Communication Problem Ver 1 01 60...
Страница 61: ...SRP E770III 7 7 USB Communication Problem Ver 1 01 61...
Страница 62: ...SRP E770III 7 8 Ethernet Communication Problem Ver 1 01 62...