14
DS901423-001
DS901423-001
15
– Press the button to be programmed. The indoor station C1 will output a confi rmation tone.
A
B
BEEP
C1
3
– Go to the indoor station that the button will call (apartment station C2) and press the door opener button.
The indoor stations C1 and C2 will be beep to indicate that they have been programmed.
A
B
BEEP
C2
1
– Hook up the handset of indoor station C1. It will beep to indicate exit from programming mode.
– Check programmed function: pick up the handset C1 and press the programmed button. Check that the
indoor station C2 rings and check audio.
– You will need to program indoor station C2 to call C1 to make the opposite call possible.
The other functions listed in the “Buttons functions” table will not be lost if the buttons are programmed
for this function because the intercom call is made with the
handset off-hook
.
DOOR PHONE CALL TONE
Five tones can be selected on B-Twin system indoor stations. The tones can be programmed also by the end
user by following the simple sequence below.
– Hold the door opener button pressed. Press and release the button
A
. The indoor station will play a tone.
– Hold the door opener button pressed and press the button
A
again to change the tone.
– Release the door opener button when you have chosen the tone you want. The tone is now programmed.
A
B
FLOOR CALL TONE
Five fl oor call tones can be selected on B-Twin system indoor stations. The tones can be programmed also by
the end user by following the simple sequence below.
Hold the door opener button pressed. Press and release the button
B
. The indoor station will play a tone.
Hold the door opener button pressed and press the button
B
again to change the tone.
Release the door opener button when you have chosen the tone you want. The tone is now programmed.
A
B
PROGRAMMING DATA DELETION
Proceed as follows to delete all optional programming data (intercom calling codes):
– Hold the door opener button pressed and pick up the handset.
– Press and
B
at the same time for 3 seconds until you hear the deletion tone.
– Release
buttons
and
B
and hang up.
The deletion procedure will not change the programmed calling tones.
TECHNICAL SPECIFICATIONS
Power voltage: .................................................................................................................. 36 ÷ 48Vdc
Stand-by consumption: ....................................................................................................... 3,0mA max
Max. consumption: .................................................................300mA max (with T-Line video door phone)
Working temperature range: .......................................................................................... - 5°C ÷ + 45°C
Reference standards: .................................................................................. EN 61000-6-3, EN 61000-6-1