Mode 3 (Operator Selection Enable ID=917 3) 

In this mode, the device tries to register on the home network for 

SIM1  or  one  of  the  enabled  networks  set  by  the  entire  list  of  enabled 

networks ID=0020-0059. 

When the power is on, the device selects profile 0, SIM1 and waits 

for it to appear and be ready.  

If the SIM-card is not detected or detected, but is not ready for a 

particular  timeout,  the  device  checks  if  the  profile  switch  (ID=0916) 
option is enabled. 

 If  the  profile  switch  is  disabled,  the  device  puts  the  modem  into 

sleep  for  particular  time.  Once  such  timeout  is  reached,  the  process  is 

repeated. 

If  the  profile  switch  is  enabled,  the  device  switches  to  profile  1, 

selects SIM2 and waits for it to be up and ready. If the SIM-card has not 
been detected within a certain timeout, or it has been detected, but not 
ready, the device switches to profile 0 and puts the modem to the sleep 

for  a  particular  timeout.  Once  such  timeout  is  reached,  the  process  is 
repeated. 

If  SIM1  is  selected,  the  device  tries  to  register  on  the  home 

network of SIM1. If the device has failed to register on the home network 

with  SIM1,  the  device  checks  if  the  profile  switch  (ID=0916)  option  is 
enabled,  and  if  it  is,  then  the  device  switches  to  profile  1  and  selects 

SIM2. 

The list of networks enabled for SIM2 is checked. If it is empty, the 

device  tries  to  register  on  the  home  network  of  SIM2.  If  the  list  is  not 
empty, the device scans for available networks. If networks are detected 

that are included to the list of enabled ones, the device tries to register 
on one of the enabled networks. If it has failed to register on any of the 
enabled  networks  detected  with  SIM2  or  no  enabled  network  has  been 

detected in the list of available networks, the device switches to profile 0 
and switches the modem to the sleep mode for a particular timeout. Once 

such timeout is reached, the process is repeated. 

 If  the  device  has  managed  to  register  on  one  of  the  enabled 

networks, it uses the parameters of profile 0 for SIM1, and profile 1 for 
SIM2,  excluding  GPRS  connection  parameters  -  APN/Usname/Uspass. 

These parameters are unique for each operator and have their own IDs 
for configuration. 

If  the  device  registers  on  the  home  network,  it  uses  the  GPRS 

access settings of profile 0 for SIM1, and of profile 1 for SIM2. 

Configuring Roaming Settings 

The configuration is given based on the example of dual-SIM device 

operation: on the home network and roaming. 

Nation  GSM  carrier  SIM-card  is  inserted  to  slot  for  SIM1  and 

roaming card goes to SIM2. 

 
Profile switch is enabled: 

setparam 0916 1; 

 

 

Содержание BI-910 TREK

Страница 1: ... UKREXIMBANK in c Kyiv MFO 380333 TIN 163033726585 www bitrek com ua sales bitrek com ua 380 44 507 02 07 03061 Ukraine c Kyiv 95 S Otradny ave Telephone 38044 507 02 07 Fax 38044 507 02 02 www bitrek com ua sales bitrek com ua Vehicles tracking device BI 910 TREK Operating Manual Version 2019 09 1 ...

Страница 2: ...onnection to a Computer 11 Indicators Description 11 List of SMS Commands 12 Structure of the SMS Commands 12 Configuring the Device 13 Detailed Description of Information Commands 15 Detailed Description of Controlling Commands 16 Basic Device Configuration 18 Security Settings 18 Configuring I O Components 19 Configuring Alarms 23 Switching Between the Profiles 24 Description of Profile Switchin...

Страница 3: ...erved Warranty The warranty period for the tracking device shall be 12 months of the date of commissioning The commissioning date must be recorded per requirements set forth in the certificate for the tracking device if no such data are available in the certificate the warranty period shall be counted starting with the tracking device shipment to the customer Manufacturer s warranty shall only be ...

Страница 4: ...ed on a non volatile memory chip Records from this log are transferred to the operator panel through a GSM channel with a predetermined frequency or on an event basis Information exchange is done via GPRS and SMS Voice communication is also supported On line terminal operation is only possible provided there is GSM coverage Beyond the GSM network coverage area the tracking device is in the mode of...

Страница 5: ... 0 V to 27 V 18 Power DC 19 Voltage from 6 v to 40 V 20 Normal current 12 V 60 mA 21 Max current 12 V 300 mA 22 Microphone Electrete 23 Microphone load resistance 2 2 kOhm 24 Outer speaker resistance 8 Ohm 25 Non volatile memory capacity 2 MB or 65 000 entries 26 Internal battery Li Ion 1 000 mAh 27 Operating temperature from 30 С to 80 С 28 RH 80 15 29 Dimensions W х L х H 125 х 95 х 33 30 Weight...

Страница 6: ...tenna 1 pc 4 Connection cable 1 pc 5 Certificate 1 pc 6 Warranty sheet 1 pc 7 Packing box 1 pc Preparation for Operation Inserting SIM Card To operate on a GSM network at least one SIM card has to be inserted into the device The second SIM card is optional and can be used for an alternative carrier network in areas with no primary carrier s coverage Contacts of the SIM card must not be saved PIN c...

Страница 7: ...urer does not supply a SIM card necessary for connecting to a GSM network You can purchase a SIM card from a local GSM carrier Sockets for Power Supply Antennas and Periphery Devices The front panel of the tracking device contains antennae connectors while its rear panel contains power supply connector discrete and analog sensors actuators and headset connectors For antennae connection SMA inlets ...

Страница 8: ...rek com ua sales bitrek com ua 380 44 507 02 07 Fig 4 Location of the Socket and Numbers of Pins Connection of the Power Supply Discrete and Analog Sensors as well as Extra Devices Fig 5 BI 910 TREK Contact Pins ...

Страница 9: ...power terminal nominal voltage is 12 VDC or 24 VDC B1 Yellow Black CAN_L Input Output CAN_L signal from the CAN bus B2 Black White M Input Mic input B3 Black Red M Input Mic input В4 White Black DOut 2 Output Discrete output No 2 B5 White An_in 1 Input Analog input No 1 B6 Oragnge DAT_low 2 Input 0 active discrete input B7 Green Red A Input Output А signal RS 485 B8 Yellow Vout Power Secure power ...

Страница 10: ...ive battery terminals ATTENTION When performing welding operations during repairs of a vehicle MAKE SURE to disconnect power cable and periphery cables Discrete inputs with active 0 respond to connection of these inputs to GND ground This input is inactive when it is not connected input is blank Discrete inputs with active 1 respond to the voltage of over 8 V on them connection of the input to the...

Страница 11: ...bps data bit 8 stop bit 1 without parity check without stream control Once the link is up the device will start sending its status data to the terminal Using the terminal program a user can send commands to the device and receive responses to them But the device first needs to send access password to the terminal in the following format TPASS password where password is an access password for the t...

Страница 12: ...ng the settings etc An SMS command should be sent together with login and password the sender s number must be included to the list of authorized contacts when such list is used Structure of the SMS Commands Any SMS with commands includes login password pair when configured and a list of different commands The commands are delimited with semicolon delimiter SMS commands entered to the tracking dev...

Страница 13: ...ed that they have been sent from one of the authorized phone numbers login password is also required if enabled If there is no authorized phone number enabled SMS with commands will be received from any phone number Configuring the Device The BI 910 TREK Tracking Device can be configured by one of the methods below 1 Using a direct connection between the device and a computer 2 Remotely using SMS ...

Страница 14: ...nal device sensors yes 6 flush Request for device profile parameters yes 7 getparam Get a parameter by its ID yes Table 4 List of Controlling Commands No Command Description Response 1 cpureset Reset of the device CPU none 2 rstallprof Reset to default profile parameters none 3 deleterecords Deletion of all records saved none 4 setparam Set a parameter by its ID yes 5 boot Update of device firmwar...

Страница 15: ...133 143 201 GSM 5 Roaming 0 Retrieval of current location of the device getstatus No Parameter name Description 1 GPS Valid data 1 Invalid data 0 2 Sat Number of visible satellites 3 Lat Latitude previous known latitude 4 Long Longitude previous known longitude 5 Alt Altitude m 6 Speed Speed km h 7 Dir Direction degrees 8 Date Date 9 Time Current GMT time Example of a response GPS 1 Sat 7 Lat 50 2...

Страница 16: ...PORT Server port 7 MODE Operating mode always 0 TCP IP Example of a response 353976012555151 internet none none 212 47 99 62 12050 0 Get the readings by parameter ID getparam ID consists of 4 digits the first digit is a profile number the last three specify ID of a parameter Example of a command request value of ID 242 parameter from profile 0 getparam 0242 No Parameter name Description 1 Param ID...

Страница 17: ...tparam 0242 www kyivstar net command setting an APN Param ID 0242 New Val www kyivstar net Device firmware update BOOT Command parameters HOST IP address of the server containing the update PORT Port of the server containing the update PATH Path to the firmware update file on the server Example of the command BOOT fw bitrek ua 80 bin Where is a version of the firmware bin file format extension Opt...

Страница 18: ...ing settings They are included to the Server GPRS and Tracking groups Once the appropriate settings are configured the device will start transmitting the data of its current location to the server All configurable settings are given in Addendum 1 Security Settings To comply with the security regulations access to the device configuration settings may be restricted When connecting the device to a c...

Страница 19: ...ly SMS from the authorized phone numbers saved to its memory If SMS login and password are enabled they must be included in each SMS with the commands Configuring I O Components The BI 910 TREK Tracking Device can collect process and send data obtained from different sensors to the server Each sensor is an I O component and has a group consisting of 6 parameters for configuration E g to configure ...

Страница 20: ... 5 monitoring going beyond range 6 monitoring going within beyond range 7 event generation by change of an input by a preset value 8 event generation by change of an input by a preset value monitoring 5 Averaging constant 0 Clarifications to Table 5 Parameter 0 enabling disabling I O component transmission to the server Parameter 1 Priority low high When selecting the Priority low option the data ...

Страница 21: ...sor readings comes within such configured range In all other cases the event will not be generated and no information will be sent to the server Example Lower threshold of input voltage is set to 0 V the upper threshold is 10 V 10 000 mV If the input voltage decreases lower than 10 V the event will be generated Figure 7 Fig 7 Generation of the Event by Going Within Range 1 Going beyond range An ev...

Страница 22: ... and the upper threshold is 10 V 10 000 mV When actual input voltage goes off the limits of a configured range the event is generated Figure 9 Fig 9 Generation of the Event by Going Within Beyond Range 3 Monitoring When this mode is selected the data will be transmitted continuously and no events will be generated 4 Monitoring Going Within Range When a Going Within Range event is generated actual ...

Страница 23: ...o make an outbound call if a particular condition is met Activation of a particular I O component constitutes such condition Voice calls must be enabled in general configuration settings of the device I O component must be enabled configured to one of the events going within range going beyond range going within beyond range its ID must be set as a trigger for outbound calls and an authorized phon...

Страница 24: ...gister on the network it switches off the modem for some time without switching between the profiles In case of successful registration on the network the device will use configuration settings of the respective profile profile 0 for SIM1 and profile 1 for SIM2 Example of profile switch enabling setparam 0916 1 ATTENTION For correct operation of the profile switch option roaming must be disabled f...

Страница 25: ...t is reached the process is repeated If the profile switch is enabled the device switches to profile 1 selects SIM2 and waits for it to be up and ready If during a particular timeout the SIM card is not detected or it is detected but not ready the device switches to profile 0 and switches the modem to the sleep mode for a certain timeout Once the sleep timeout is reached the device selects SIM1 an...

Страница 26: ... scans for available networks If networks are detected that are included to the list of enabled ones the device tries to register on one of the enabled networks If the device has failed to register on any of the enabled networks detected using SIM1 or if there are no enabled networks in the list of available networks the device checks if the profile switch ID 0916 option is enabled If the profile ...

Страница 27: ...tch ID 0916 option is enabled and if it is then the device switches to profile 1 and selects SIM2 The list of networks enabled for SIM2 is checked If it is empty the device tries to register on the home network of SIM2 If the list is not empty the device scans for available networks If networks are detected that are included to the list of enabled ones the device tries to register on one of the en...

Страница 28: ...rati on Capacity Parameter purpose 1 UsAPNTable 0060 0099 string List of APNs of enabled carriers 2 UsLoginTable 0100 0139 string List of GPRS logins of enabled carriers 3 UsPassTable 0140 0179 string List of GPRS passwords of enabled carriers Specify APNs of enabled networks setparam 0060 APN setparam 0061 APN setparam 0099 APN Specify GPRS logins of enabled networks setparam 0100 GPRS login setp...

Страница 29: ...er there is also a feature for control of discrete outputs Out 1 and Out 2 depending on the cards being read For this the device is capable of storing up to 20 card numbers in non volatile memory If a number of a card being read matches one of the card numbers saved to the memory the device activates one of the discrete outputs Network addresses 3 9 and 10 are reserved for operation with RFID read...

Страница 30: ... Parasite Power Pattern Term inal No Tracker conductor color Signal type Meter conductor color Signal type Purpose А2 Violette Black 1 wire PWR White Power Output 3 3 V for device power supply 1 Wire 15 mA max А3 Green Yellow 1_wire Green Signal 1 Wire interface data signal С1 Black GND Brown Power Ground earth Configuration example Enabling thermometer servicing setparam 0990 1 Readings from ther...

Страница 31: ...processed raw data from the level meters as well as the data processed with Kalman filter Optimal filtration factors for Kalman filter are set by default Filtered and non filtered values are transmitted by different I O components Moreover if the level meters are equipped with an in built temperature sensor data from it can be retrieved and transmitted to a server Also when fuel level meters are u...

Страница 32: ...use of a backup server setparam 0196 1 IP Host2 setparam 0188 111 1 111 11 Port2 setparam 0189 11 Configuring Engine Lock The BI 910 TREK Tracking Device together with a normally closed relay can be used to lock the engine of the vehicle Lock is enabled by sending an SMS message to the device Example of the SMS command for locking engine DOUT2 setdigout 01 Example of the SMS command for locking en...

Страница 33: ...end the response ignitionon To disable the ignition lock the following command is used ignitionoff When the lock is disabled the device will send the response ignitionoff ATTENTION The ignitionon ignitionoff commands will be performed by the device provided that they have been received via SMS message ...

Страница 34: ...Host1 0188 none String Backup server IP address none IP or DNS 31 28 163 20 ipsPort1 0189 none 2 Byte Backup server PORT none PORT 20127 APN 0242 none String GPRS access point none APN gps utel ua Usname 0243 none String GPRS access login none User Name none Uspass 0244 none String GPRS access password none User Password none Send Period 0270 none 2 byte Transmission to server time sec 0 65535 60 ...

Страница 35: ... distance of retrieval none 0 disabled 1 enabled 1 Enable Angle Period 0902 none 1 Byte Enabling azimuth of retrieval none 0 disabled 1 enabled 1 Day Period 0903 none 2 byte Enabling time of retrieval with the ignition on sec 0 65535 30 Night Period 0011 none 2 byte Enabling time of retrieval with the ignition off sec 0 65535 30 Dist Period 0012 none 2 byte Retrieval period by distance meter s 0 6...

Страница 36: ...ent stop by acceleration meter 0 1 sec 0 65535 200 Axel Sleep Enable 0911 none 1 byte Enabling sleep by acceleration meter none 0 disabled 1 enabled 0 WAIT_SLEEP_ TIMEOUT 4007 none 2 byte Timeout for sleep by acceleration meter minut es 5 65535 15 SLEEP_ TIMEOUT 4008 none 2 byte Sleep timeout by acceleration meter minut es 0 65535 720 min_GPS_ speed 0918 none 1 byte Minimum speed according to GPS ...

Страница 37: ...zed phone number 4 xxxxxxxxxxxx Phone5 0266 none String Authorized phone number 5 xxxxxxxxxxxx Phone6 0267 none String Authorized phone number 6 xxxxxxxxxxxx Phone7 0268 none String Authorized phone number 7 xxxxxxxxxxxx Phone8 0269 none String Authorized phone number 8 xxxxxxxxxxxx SMS Login 0252 none String SMS access login Login SMS Password 0253 none String SMS access password Password Termina...

Страница 38: ...ifetime min 1 65535 480 Voice communication InputCall Trigger 0994 none 1 byte Response to incoming call with digital inputs 0 disabled 1 6 ID of I O component digital input used for response to incoming call 0 ringNum 0912 none 1 byte Number of rings prior to auto phone pickup pcs 1 256 3 Microphone Level 0995 none 1 byte Headset mic level adjustment c u 0 7 4 speakerLevel 0996 none 1 byte Headse...

Страница 39: ...omponent triggering SMS to be sent to an authorized phone number in cases of event generation ID SMSText 0817 none string Text added to SMS NMT 30 Latin characters Text Roaming Operator Selection Enable 0917 none 1 byte Enabling carrier selection 0 disabled 1 2 3 enabled different modes 0 UsipTable 0020 0059 none string List of enabled carriers xxxxx UsAPNTable 0060 0099 none string List of APNs o...

Страница 40: ...ation FuelCounter Mode 0993 none 1 byte Fuel meter mode none 0 absolute fuel economy 1 instantaneous fuel economy 0 AIN1_filter_ period 0959 none 2 byte Period of data retrieval by AIN1 median filtering X 1 50m S 19 AIN2_filter_ period 0980 none 2 byte Period of data retrieval by AIN2 median filtering X 1 50m S 19 MIN_duration _of_fuel 0349 none 1 byte Filter of digital inputs dlow3 dlow4 Levels b...

Страница 41: ...g_period _radio_ module 0199 none 2 byte Polling period of RS485 based wireless sensor of tailing equipment 0 1 sec 100 polling_period _iButton 0208 none 2 byte Polling period for RS485 iButton 0 1 sec 100 polling_period _tsens 0206 none 2 byte Polling period for RS485 Tsens 0 1 sec 100 polling_period _RFID_RKS 0201 none 2 byte Polling period for RS485 RFID RKS SOVA 0 1 sec 15 FactorF 0950 none 4 ...

Страница 42: ...0000000 FactorRm 0954 none 4 byte R factor for Kalman filter with movement c u 400000000 switchFilters 0209 none 1 byte Switching between filter types for filtered fuel meters none 1 Kalman filter 1 Ekey_num 0920 0939 none 8 byte ID of enabled electronic keys none ID 1 GSM_Reg_ Timeout 4019 none 2 byte Timeout for registration on the GSM network sec 60 300 120 GPRS_Reg_ Timeout 4020 none 2 byte Ti...

Страница 43: ...ard and outputs control none 0 disabled iButton 9 controlling DOUT1 10 controlling DOUT2 RFID network address 3 5 controlling DOUT1 6 controlling DOUT2 RFID network address 9 13 controlling DOUT1 14 controlling DOUT2 RFID 10 network address 17 controlling DOUT1 18 controlling DOUT2 0 iButtonEn 0991 none 1 byte Enabling electronic ID key none 0 disabled 1 enabled 0 TsensEn 0990 none 1 byte Enabling...

Страница 44: ...nsor of tailing equipment none 0 disabled 1 enabled 0 canID1 3326 none 4 byte IDs of CAN messages received none ID 0 canID2 3327 none 4 byte IDs of CAN messages received none ID 0 canID3 3328 none 4 byte IDs of CAN messages received none ID 0 canID4 3329 none 4 byte IDs of CAN messages received none ID 0 canID5 3330 none 4 byte IDs of CAN messages received none ID 0 canID6 3331 none 4 byte IDs of ...

Страница 45: ...ages received none ID 0 canID8 3333 none 4 byte IDs of CAN messages received none ID 0 canID9 3334 none 4 byte IDs of CAN messages received none ID 0 CAN_ DMASK_ID 1 0326 none 2 byte Mask of bytes received c u 0 255 0 CAN_ DMASK_ID 2 0327 none 2 byte Mask of bytes received c u 0 255 0 CAN_ DMASK_ID 3 0328 none 2 byte Mask of bytes received c u 0 255 0 CAN_ DMASK_ID 4 0329 none 2 byte Mask of bytes...

Страница 46: ...values Default values CAN_ DMASK_ID 5 0330 none 2 byte Mask of bytes received c u 0 255 0 CAN_ DMASK_ID 6 0331 none 2 byte Mask of bytes received c u 0 255 0 CAN_ DMASK_ID 7 0332 none 2 byte Mask of bytes received c u 0 255 0 CAN_ DMASK_ID 8 0333 none 2 byte Mask of bytes received c u 0 255 0 CAN_ DMASK_ID 9 0334 none 2 byte Mask of bytes received c u 0 255 0 ...

Страница 47: ...1 byte Digital input responding to log 0 none 0 enabled 1 disabled dlLow4 0370 0375 4 1 byte Digital input responding to log 0 none 0 enabled 1 disabled dlHigh1 0540 0545 5 1 byte Digital input responding to log 1 none 0 disabled 1 enabled dlHigh2 Ignition 0550 0555 6 1 byte Digital input responding to log 1 reserved for ignition connection none 0 disabled 1 enabled GSMCSQ 0470 0475 21 1 byte GSM ...

Страница 48: ...Availability of GPS signal pcs pcbTemp 0440 0445 70 4 byte Device temperature C Real Odometr 0500 0505 199 4 byte Relative virtual odometer km Odometr 0710 0715 200 4 byte Absolute virtual odometer km fuelCounter 0460 0465 76 4 byte Fuel meter pulse difference between dlLow3 and dlLow4 meter inputs c u fuelLevel1 0580 0585 100 2 byte Polling filtered fuel meter network address 1 c u fuelLevel2 059...

Страница 49: ...5 113 2 byte Polling non filtered fuel meter network address 2 c u fuelLevel Unfilt5 0870 0875 131 2 byte Polling non filtered fuel meter network address 5 c u fuelLevel Unfilt6 0880 0885 132 2 byte Polling non filtered fuel meter network address 6 c u fuelTemp1 0600 0605 102 1 byte Fuel temperature per fuel meter network address 1 C fuelTemp2 0610 0615 103 1 byte Fuel temperature per fuel meter n...

Страница 50: ... 2 byte Thermometer 2 readings C TSens3 0660 0665 109 2 byte Thermometer 3 readings C TSens4 0670 0675 110 2 byte Thermometer 4 readings C fuelCounter 1 0180 0185 136 4 byte Direct flow pulse counter dlLow3 c u fuelCounter 2 0190 0195 137 4 byte Reverse flow pulse counter dlLow4 c u 1_Wire 0400 0405 78 8 byte iButton identifier electronic key none OperCode 0680 0685 111 4 byte Transmission of carr...

Страница 51: ...lt values SIM_Stat 0790 0795 121 1 byte SIM card status none 0 no SIM detected 1 SIM detected 2 SIM detected but not ready 3 SIM detected and ready GSM_Stat 0760 0765 118 1 byte GSM network registration status none 0 not registered and not searching for carriers 1 home network 2 not registered but searching for carriers 3 registration disabled 4 status unknown 5 roaming ...

Страница 52: ...home network 2 not registered but searching for carriers 3 registration disabled 4 status unknown 5 roaming GPRS_ content_ stat 0780 0785 120 1 byte GPRS content activation status none 0 not activated 1 activated count_dLow 1 0830 0835 125 4 byte Frequency input transmission of number of pulses per 5 sec c u fast_dlLow1 0320 0325 155 4 byte Instantaneous pulse counter minimum measurement is 1mS c ...

Страница 53: ...25 105 8 byte RFID identifier network address 3 none RFID_RKS_ 9 3800 3805 157 8 byte RFID RKS identifier СОВА network address 9 none RFID_RKS_ 10 3830 3835 160 8 byte RFID RKS identifier СОВА network address 10 none TimeSaving 5000 5005 190 4 byte Device operation time minutes axesX 0720 0725 114 1 byte Actual value of X direction elevation angle degrees 0 255 axesY 0730 0735 115 1 byte Actual va...

Страница 54: ...nt CAN2 c u 0 setIO_CAN3 3640 3645 147 8 byte Activation of I O component CAN3 c u 0 setIO_CAN4 3650 3655 148 8 byte Activation of I O component CAN4 c u 0 setIO_CAN5 3660 3665 149 8 byte Activation of I O component CAN5 c u 0 setIO_CAN6 3670 3675 150 8 byte Activation of I O component CAN6 c u 0 setIO_CAN7 3680 3685 151 8 byte Activation of I O component CAN7 c u 0 setIO_CAN8 3690 3695 152 8 byte...

Страница 55: ...18 Ver 2018 06 1 Basic document 09 07 2018 Ver 2018 07 1 Changed the firmware update port number 09 10 2018 Ver 2018 10 1 Added new I O element IDconf 0907 09 09 2019 Ver 2019 09 1 The description of the section describing the principle of working with the list of prohibited operators has been expanded ...

Отзывы: