to 10 V (10 000 mV). Rising of the voltage above 10 V will generate
the event (see Figure 6).
Figure 6 – Generation of event by leaving the range.
2 – Returning/leaving to/of the range.
Event is generated every time when the actual value of the sensor
is out of the limits of the predetermined range.
Example:
The lower voltage limit is set to 5 V (5 000 mV), the
upper limit is set to 10 V (10 000 mV). When the actual voltage
crosses limits of the specified range, then event is generated (see
Figure 7).
Figure 7 – Generation of event by returning/leaving to/of the
range.
3 – Monitoring.
When this mode is selected, data will be transmitted continuously,
the events will not be generated.
4 – Moni entering the range.
When there is generated the event after entering the range, the
actual value of the sensor starts to be transmitted to the server in
the monitoring mode.